• 제목/요약/키워드: WMS(Wavelength Modulation Spectroscopy)

검색결과 5건 처리시간 0.022초

파장 변조 기법을 이용한 연소배기 가스의 계측 (Measurement of Exhaust Gas Concentration using Wavelength Modulation Spectroscopy)

  • 김동혁;김세원;신명철;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.97-103
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser. Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. On-line data acquisition and processing can be performed with a PC running LabVIEW software, and absorption signals are measured simultaneously by multiplexing method. Finally, It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

연소배기 가스의 계측을 위한 다이오드 레이저 센서 (Diode-Laser Absorption Sensors for measurement of combustion Gas)

  • 신명철;김세원;김동혁
    • 한국연소학회지
    • /
    • 제11권3호
    • /
    • pp.26-35
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser, Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. The results showed that gas concentrations of $O_2$, CO, $CO_2$, NO are accurately measured within ${\pm}2%$ error. The application of WMS method increased the beam intensity 2-3 times higher than DA method. It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

다이오드 레이저를 이용한 연소진단기법 (Combustion Diagnostics Method Using Diode Laser Absorption Spectroscopy)

  • 차학주;김민수;신명철;김세원;김혁주;한재원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.75-83
    • /
    • 2003
  • Diode laser absorption system is advantageous of their non-invasive nature, fast response time, high sensitivity and real-time measurement capability. Furthermore, recent advances in room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system are now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and develope new gas sensing system. It experimentally found out that the wavelength, power characteristics as a function of injection current and temperature. In addition to direct absorption and wavelength modulation spectroscopy have been demonstrated in these experiments and have a bright prospect to this diode laser system.

  • PDF

다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구 (The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser)

  • 김세원;신명철;이창엽;윤성운;김영일
    • 한국연소학회지
    • /
    • 제17권1호
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정 (Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region)

  • 송아란;정낙원;배성우;황정호;이창엽;김대해
    • 청정기술
    • /
    • 제26권4호
    • /
    • pp.293-303
    • /
    • 2020
  • 세계보건기구에 따르면 대기오염은 건강에 대한 주요 위험원으로 대기오염으로 인해 매년 약 700만 명의 조기 사망이 발생하고 있다. 이산화황(SO2)은 대표적인 대기오염물질로 황 성분이 포함된 연료의 연소에서 다량 발생한다. SO2 발생량을 감소시키기 위해서는 대형 연소 환경에서 이를 실시간으로 정밀하게 측정하고 측정 값을 바탕으로 저감 설비를 최적화하는 과정이 필요하다. 이 논문에서는 미세먼지 전구물질인 SO2의 농도를 측정하기 위해 파장 가변형 다이오드 레이저 흡수 분광법 중 파장 변조 분광법을 이용하였다. 광원으로는 7.6 ㎛ 양자 폭포 레이저를 사용하였고 7623.7 ~ 7626.0 nm 사이의 64개 다중 광흡수선으로 SO2 농도 측정이 가능함을 증명하였다. 실험은 1 atm, 296 K에서 28, 76 m multi-pass cell을 사용하여 수행되었다. SO2 농도는 고농도(1000 ~ 5000 ppm)와 저농도(10 ppm 이하)로 두 종류로 실험 하였다. 추가적으로 가스 셀 외에 레이저가 지나가는 경로에 질소를 채워 대기 중의 H2O가 SO2 측정에 미치는 영향을 확인하였다. SO2는 3 ppm까지 측정하였고 측정된 SO2 농도는 전기 화학식 센서와 NDIR 센서 측정 결과와 비교되었다.