• Title/Summary/Keyword: WLAV

Search Result 8, Processing Time 0.02 seconds

Identification of Parameter Errors in Electric Power Systems by WLAV State Estimation (WLAV 상태추정에 의한 전력계통 파라미터 에러 추정에 관한 연구)

  • Kim, Hong-Rae;Gwon, Hyeong-Seok;Kim, Dong-Jun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.9
    • /
    • pp.451-458
    • /
    • 2000
  • This paper addresses the issues of the parameter error detection and identification in electric power systems. In this paper, the parameter error identification and estimation is carried out as part of the state estimation. A two stage estimation procedure is used to detect and identify the parameter errors. The suspected parameters are identified by the WLAV state estimator as the first stage. A new WLAV state estimator adding the suspected system parameters in the state vector is used to estimate the exact value of parameter errors. Supporting examples are given by using IEEE 14 bus system.

  • PDF

An Algorithm for Transformer Tap Estimation by WLAV State Estimator (가중최소절대값을 이용한 변압기 텝 추정 알고리즘)

  • Kim, Hong-Rae;Kwon, Hyung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.279-281
    • /
    • 1999
  • This paper addresses the issues of the parameter error detection and identification in power system. The parameter error identification is carried out as part of the state estimation procedure. The weighted least absolute value(WLAV) estimation method is used for this procedure. The standard formulation of the state estimation problem is modified to include the effects of the parameter errors as well. A two step procedure for the detection and identification of faulted parameters is proposed. Supporting examples are given using IEEE 14 bus system.

  • PDF

Real-Time Identification and Estimation of Transformer Tap Ratios Containing Errors

  • Kim, Hongrae;Kwon, Hyung-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.109-113
    • /
    • 2002
  • This paper addresses the issue of parameter error identification and estimation in electric power systems. Parameter error identification and estimation is carried out as a part of the state estimation. A two stage estimation procedure is used to detect and identify parameter errors. Suspected parameters are identified by the WLAV state estimator in the first stage. A new WLAV state estimator adding suspected system parameters in the state vector is used to estimate the exact values of parameters. Supporting examples are given by using the IEEE 14 bus system.

Development of The Robust State Estimator using Linear Programming (선형계획법을 이용한 견실한 상태추정기의 개발에 관한 연구)

  • Lim, Jae-Sup;Kwon, Hyung-Seok;Kim, Hong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.181-183
    • /
    • 2001
  • This paper presents a robust power system state estimator using linear programming(LP). LP state estimators minimize the weighted sum of the absolute values of the measurement residuals. In this paper, WLS(weighted least square) and WLAV(weighted least absolute value) state estimators are run with same measurement sets including bad data in order to compare the robustness to bad data and convergence characteristics of the two methods. Simulations with three test cases are performed and the results are presented, using IEEE 14 bus system.

  • PDF

Optimal Placement of Distributed Generations Considering System Losses and State Estimation in Composite Distribution Systems (복합배전계통에서 계통손실을 고려한 분산형 전원의 위치선정 및 상태추정)

  • Kwon Hyung-Seok;Kim Hongrae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.533-538
    • /
    • 2004
  • Recently, it is increasing the concern of distributed generations(DGs) that installed small power at a site near by the customer. In deregulation environment, not only distributed generation operation but also state estimation is the key function in distribution systems. This paper process to calculate the impact of distributed generation on a distribution feeder. WLAV state estimation is performed the distribution systems with DGs and bad data test including single, multiple, interacting. Simulations with test cases are performed and the results are presented, using IEEE 34 bus radial distribution systems

  • PDF

Identification of Leverage Points for Power System State Estimation (전력개통 상태추정을 위한 leverage point 판별에 관한 연구)

  • Lee, Koang-Kee;Lim, Jae-Sub;Kwon, Hyung-Seok;Kim, Hong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.212-214
    • /
    • 2002
  • Existence of leverage points was claimed to be the reason for the WLAV estimator failing to reject bad data in the measurements. This paper presents an impact of leverage points on the result of power system state estimation. State estimator is run with measurement sets with gross error and leverage point. Three test cases are performed and the results are presented using IEEE 30 bus system.

  • PDF

State Estimation on the Composite Distribution System with Distributed Generation (분산전원이 포함된 복합배전계통 상태추정)

  • Lim, Jae-Sup;Lee, Koans-Kee;Kwon, Hyung-Seok;Kim, Hong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.206-208
    • /
    • 2002
  • Distributed generation (DG) is predicted to play an increasing role in the electric power system of the near future. Distributed generation is by definition that is of limited size (roughly 10MW or less) and interconnected at the substation, distribution feeder or customer load levels. The effects of generation sources within a distribution network on the system losses are investigated in this paper. WLAV state estimation is performed with the composite distribution system containing DG. Simulations with test cases are performed and the results are presented, using IEEE34 bus radial distribution system.

  • PDF

Estimation of Branch Topology Errors in Power Networks by WLAN State Estimation (최소절대값 상태추정에 의한 전력계통 선로 토폴로지 에러의 추정)

  • Kim, Hong-Rae;Song, Gyeong-Bin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.259-265
    • /
    • 2000
  • The purpose of this paper is to detect and identify topological errors in order to maintain a reliable database for the state estimator. In this paper, a two stage estimation procedure is used to identify the topology errors. At the first stage, the WSAV state estimator which has characteristics to remove bad data during the estimation procedure is run for finding out the suspected branches at which topology errors take place. The resulting residuals are normalized and the measurements with significant normalized residuals are selected. A set of suspected branches is formed based on these selected measurements; if the selected measurement is a line flow, the corresponding branch is suspected; if it is an injection, then all the branches connecting the injection bus to its immediate neighbors are suspected. A new WLAV state estimator adding the branch flow errors in the state vector is developed to identify the branch topology errors. Sample cases of single topology error and topology error with a measurement error are applied to IEEE 14 bus test system.

  • PDF