• Title/Summary/Keyword: WEC

Search Result 166, Processing Time 0.029 seconds

THE EFFECT OF GINSENG ON THE POSTOPERATIVE NUTRITIONAL STATUS AND IMMUNE FUNCTIONS OF GASTRIC CARCINOMA PATIENTS

  • Woo Y.M.;Lee H.W.;Kim J.P.
    • Proceedings of the Ginseng society Conference
    • /
    • 1993.09a
    • /
    • pp.61-65
    • /
    • 1993
  • To find out the mechanisms of anticancer effect of ginseng, we performed prospective randomized study for the 39 patients with stomach cancer who had undergone radical subtotal or total gastrectomy and postoperative immunochemotherapy with PMF from July 1991 to November 1991 at Department of Surgery, Seoul National University Hospital. The patients were randomly divided into study and control group: the study group was administered with powdered red ginseng of 5400mg daily dose for 12 months postoperatively, the control group was simply followed-up. There were no significant differences between study and control group in twelve months postoperative body weights, triceps skin fold, hemoglobin. albumin, total protein, PNI, total WEC and lymphocyte count, and T-cell percentage (p>0.05). The results of preoperative DNCB skin test of study group was (0) for 8 patients and (+) for 12 patiens. but after operation, it showed the tendency of decreasing (0) and (+) ratio and increasing tendency of (++) ratio (p<0.05), but those of control group showed no increasing tendency of the degree of positive DNCB skin test. From the above results, we could conclude that ginseng had anti - cancer effect by the way of immune mechanism and could be an adjunct to the patients with stomach cancer postoperatively.

  • PDF

Investigation of Moving Angle of Power Take off Mechanism on the Efficiency of Wave Energy Converter (파력발전기의 동력인출장치의 회전각도가 효율에 미치는 영향 분석)

  • Do, H.T.;Nguyen, M.T.;Phan, C.B.;Lee, S.Y.;Park, H.G.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.25-35
    • /
    • 2015
  • The hydraulic power-take-off mechanism (HPTO) is one of the most popular methods in wave energy converters (WECs). However, the conventional HPTO with only one direction motion has a number of drawbacks that limit its power capture capability. This paper proposes an adjustable moving angle wave energy converter (AMAWEC) and investigates the effect of the moving angle on the performance of the wave energy converter to find the optimal moving angle in order to increase the power capture capability as well as energy efficiency. A mathematical model of components from a floating buoy to a hydraulic motor was modeled. A small scale WEC test rig was fabricated to verify the power capture capability and efficiency of the proposed system through experiments.

Development and Performance Test of Hydraulic PTO for 50㎾ Class Rotating Body Type Wave Energy Converter (50㎾급 동체회전형 파력발전시스템 유압식 전력변환장치 개발 및 성능시험)

  • Choi, Kyung-Shik;Yang, Dong-Soon;Park, Shin-Yeol;Cho, Byung-Hak
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • 50kW급 동체회전형 파력발전시스템(WEC;wave energy converter)의 전력변환장치(PTO; power take-off)를 설계 제작한 후 성능시험을 하였다. 파력발전시스템은 2개의 실린더형 동체가 회전관절로 연결된 구조로 수면의 반정도 잠기는 구조로 되어있다. 파랑에 의해 유도된 회전관전의 움직임이 유압실린더에 힘을 가해주며, 유압실린더는 고압의 작동유를 축압기를 경유하여 발전기에 체결된 유압모터로 공급한다. 유압식 PTO은 유압실린더가 왕복운동하는 움직임을 이용하여 고품질의 전력을 생산하는데 효과전인 수단을 제공한다. 파력발전시스템의 경제성은 PTO의 에너지 변환 효율에 크게 의존한다. 발전기를 AC 380V 전력계통에 연계시킨 후, 발전기에서 나오는 출력이 5, 20, 35, 43kW 일때 PTO 전체와 개별기기에 대한 효율을 측정하였다. 본 논문에서 유압식 PTO시스템의 설계에 대해 설명하였으며 효율 향상에 초점을 맞추어 PTO 성능대해 분석하였다.

Comparison of Stress Intensity Factors for Cylindrical Structure with Circumferential Through-Wall Cracks subjected to Tensile Load (원주방향 관통균열이 존재하는 원통형 구조물의 인장하중에 의한 응력확대계수 비교)

  • Dal Woo Jung;Chang Kyun Oh;Hyun Su Kim;Hyeong Do Kweon;Jun Seok Yang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • To date, a number of stress intensity factor (SIF) solutions have been proposed for the cylindrical structure with circumferential through-wall cracks. However, each solution has a different format as well as applicable range. It is also known that there is a significant difference in predicted SIF values depending on the shape of the structure and the size of the crack. In this study, the applicability of various SIF solutions was analyzed by comparing the finite element analysis results for the case where a tensile load is applied to the cylindrical structure with circumferential through-wall crack. It is found that the calculated SIF gradually decreases and converges to a certain value with increasing length-to-radius ratio. Therefore, an appropriate length-to-radius ratio should be set in consideration of the dimensions of the actual cylindrical structure. For piping with sufficiently long cylinder, the ASME solution is found to be the most appropriate, and for a short cylinder, the API solution should be applied. On the other hand, the WEC solution requires careful attention to its application.

One-way Coupled Response Analysis between Floating Wind-Wave Hybrid Platform and Wave Energy Converters (부유식 풍력-파력발전 플랫폼과 탑재된 파력발전기와의 단방향 연성 운동 해석)

  • Lee, Hyebin;Bae, Yoon Hyeok;Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.84-90
    • /
    • 2016
  • In this study, a six degree-of-freedom motion analysis of a wind-wave hybrid platform equipped with numerous wave energy converters (WECs) was carried out. To examine the effect of the WECs on the platform, an analysis of one-way coupling was carried out, which only considered the power take-off (PTO) damping of the static WECs on the platform. The equation of motion of a floating platform with mooring lines in the time domain was established, and the responses of the one-way coupled platform were then compared with the case of a platform without any coupling effects from the WECs. The hydrodynamic coefficients and wave exciting forces were obtained from the 3D diffraction/radiation pre-processor code WAMIT based on the boundary element method. Then, an analysis of the dynamic responses of the floating platform with or without the WEC effect in the time domain was carried out. All of the dynamics of a floating platform with multiple wind turbines were obtained by coupling FAST and CHARM3D in the time domain, which was further extended to include additional coupled dynamics for multiple turbines. The analysis showed that the PTO damping effect on platform motions was negligible, but coupled effects between multiple WECs and the platform may differentiate the heave, roll, and pitch platform motions from the one without any effects induced by WECs.

A study for electric power of float-counterweight wave energy converter (복수 연결된 부유체-균형추식 파력발전장치의 전력량에 관한 연구)

  • Lee, Sung-Bum;Hadano, Kesayoshi;Moon, Byung-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.936-942
    • /
    • 2014
  • As a result of the exhaustion of fossil fuel, interest about renewable energy is increasing day by day. Inter alia, study for wave power energy of which the calculability is high and the available amount is abundant is going along actively. As a float-countweight wave energy converter is equivalent improved structural strength compared with oscillating body type. we made the wave only in order to up and down motion by setting up bulkhead which is called wave camber at the outside of float. This paper mainly focuses on generation amount of plural connected float-counterweight wave energy converter and we calculate the amount. The result, we confirmed that the more a numerical value of nl/L increases, the more amount of electricity rises and also when it is over nl/L=0.40, it is possible to get continuous generation. Through this study, we can use as basic data for design of wave chamber on advantageous condition at the real seas and by way of estimation for generation amount.

Interaction Analysis on Deployment of Multiple Wave Energy Converters in a Floating Hybrid Power Generation Platform (부유식 복합발전 플랫폼내의 다수 파력발전기 배치를 위한 상호작용 해석)

  • Lee, Hyebin;Cho, Il Hyoung;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 2016
  • In this study, the present deployment of the multiple wave energy converters (WECs) in a floating wind-wave hybrid power generation platform was estimated considering the interaction effect among WEC buoys. The interaction processes of multiple buoys were very complex, since scattered and radiated waves from each buoy affected the others in the array. The interaction analysis of the diffraction and radiation problem by the array of WECs was applied by matched eigenfunction expansion method (MEEM). The analytical solutions were compared with the results of numerical calculation based on WAMIT. The overall performance of 24 WECs installed in the hybrid power generation platform was evaluated by the q-factor representing the interaction effect among buoys.

Latching Control Strategy for Improvement Wave Energy Conversion in Irregular Waves (불규칙파중 파랑에너지 변환효율 향상을 위한 래칭 제어전략)

  • Cho, Il Hyoung;Kim, Jeong Rok;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.291-297
    • /
    • 2015
  • The wave spectrum was generated from wave data measured at the Chagwi-do site in Jeju, where a 10MW class floating wave-offshore wind hybrid power generation system will be installed. The latching control technology (Sheng et al.[2015]) was applied in order to improve the extracted power from WEC (Wave Energy Converter), which is heaving in corresponding irregular waves. The peak period as a representative value of irregular waves was used when we determined the latching duration. From the numerical results in the time-domain analysis, the latching control technology can significantly improve the extracted power about 50%.

Correlation of Reflection Coefficient and Extracted Efficiency of an Oscillating Water Column Device in Front of a Seawall (안벽 앞에 설치된 진동수주형 파력발전장치의 반사율과 추출효율과의 상관관계)

  • Cho, Il Hyoung;Kim, Jeongrok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.242-251
    • /
    • 2020
  • In this study, the extraction efficiency and reflection coefficient by a two-dimensional OWC (Oscillating Water Column) WEC (wave energy converter) installed in front of a seawall was investigated for regular/irregular waves. The matched eigenfunction expansion method (MEEM) based on the linear potential theory was applied as an analytical tool. The diffraction problem by the incident wave in the open-chamber and the radiation problem by the oscillating pressure in the closed-chamber were solved to obtain the volume fluxes at the internal free-surface. Applying the volume fluxes into the continuity equation for the airflow in a chamber, we got the oscillating air pressure. The maximum extracted power and corresponding reflection coefficient were determined at the optimal turbine coefficient that maximizes the extracted power. OWC device designed for a high extracted efficiency simultaneously contributes to reduce reflected waves.

Characteristics of Multiple Organ Failure in Baby Rats (어린 백서에서 패혈증으로 유발된 다발성 장기 부전증의 특성)

  • Yoo, Soo-Young;Roh, Kwang-Soo;Jung, Jin-Hyung;Kim, Il-Ho;Ko, Yong-Taek
    • Advances in pediatric surgery
    • /
    • v.6 no.1
    • /
    • pp.10-18
    • /
    • 2000
  • Multisystem organ failure resulting from gram negative bacterial sepsis is associated with high morbidity and mortality in surgical neonates. There are differences in the clinical characteristics of organ failure in neonates and adults. The purpose of this study is to identify the differences and determine the order of organ failure between baby rats and adult rats after induction of gram negative sepsis. Fifty baby rats less than 30-day-old and another 50 adult rats more than 2-month-old were divided into control group (G1) and experimental group (G2). The G1 consisted of 10 baby- and 10 adult-rats, and the G2 consisted of 40 babies and 40 adults. E. coli ($10^8/mL$ per 100g of body weight) were injected into the peritoneal cavity in G2 and same amount of saline was injected in G 1. Blood samples were obtained before injection, 24 hour, 48 hour, 72 hour and after death. WEC, platelet, $PaO_2$, $PaCO_2$, total bilirubin, BUN, creatinine, albumin and abdominal wall thickness were measured to evaluate the sequence of organ failure. The mortality was 55.0 % in G2-babies and 32.5 % in G2-adults. In baby rats, microvascular, hematologic and renal failure appeared within 24 hours after injection and pulmonary failure followed. Pulmonary, renal and liver failure developed within 24-48 hours in adult rats; however, microvascular failure did not appear until they were moribund. Thrombocytopenia, hypoalbuminemia, increased BUN and generalized edema was the earlist sign of sepsis in baby rats.

  • PDF