• 제목/요약/키워드: W-W Test

검색결과 4,640건 처리시간 0.04초

A Study of the Flow Phenomenon of Water in a Channel with Flat Plate Obstruction Geometry at the Entry

  • Khan, M.M.K.;Kabir, M.A.;Bhuiyan, M.A.
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.879-887
    • /
    • 2003
  • The flow in a parallel walled test channel, when obstructed with a geometry at the entrance, can be forward, reverse and stagnant depending on the position of the obstruction. This interesting flow phenomenon has potential benefit in the control of energy and various flows in the process industry In this experiment, the flat plate obstruction geometry was used as an obstruction at the entry of the test channel. The parameters that influence the flow inside and around the test channel were the gap (g) between the test channel and the obstruction geometry, the length (L) of the test channel and the Reynolds number (Re). The effect of the gap to channel width ratio (g/w) on the magnitude of the velocity ratio (V$\_$i/ / V$\_$o/ : velocity inside/ velocity outside the test channel) was investigated for a range of Reynolds numbers. The maximum reverse flow observed was nearly 20% to 60% of the outside velocity for Reynolds number ranging from 1000 to 9000 at g/w ratio of 1.5. The maximum forward velocity inside the test channel was found 80% of the outside velocity at higher g/w ratio of 8. The effect of the test channel length on the velocity ratio was investigated for different g/w ratios and a fixed Reynolds number of 4000. The influence of the Reynolds number on the velocity ratio is also discussed and presented for different gap to width ratio (g/w). The flow visualisation photographs showing fluid motion inside and around the test channel are also presented and discussed.

ISO 9705 Room-Corner Test와 모델 평가 (ISO 9705 Room-Corner Test & Model simulations)

  • 김운영
    • 한국화재소방학회논문지
    • /
    • 제13권2호
    • /
    • pp.3-11
    • /
    • 1999
  • ISO 9705 room-corner test 기준에 따른 가연성 내장재의 화재위험성 평가를 위해 개발된 Quintiere 모델의 검증을 위해 이태리 L. S. F의 실대 화재 실험 결과와 비교 분석하였다. ISO 9705 시험은 최초 10분간은 100 kW, 이후 10분간은 300 kW의 화원에 노출된 벽, 천장재의 화염확산 성능 평가방법으로 열 방출비율이 1 MW에 이르면 플레쉬오버가 발생한다고 판단한다. 총 13개의 재료 중 실제 화재 시 용융, 박락, 변형 등이 나타나는 경우는 단위 면적 당 발생 열량 수정 값을 적용하였다. 바탕 면에 계속 부착되어 있는 마감재의 예측결과는 실험 결과에 근접하였다. 또한 Large-scale Test의 실험결과와 모델의 예측성능도 비교 분석하였다.

  • PDF

CONFLICT AMONG THE SHRINKAGE ESTIMATORS INDUCED BY W, LR AND LM TESTS UNDER A STUDENT'S t REGRESSION MODEL

  • Kibria, B.M.-Golam
    • Journal of the Korean Statistical Society
    • /
    • 제33권4호
    • /
    • pp.411-433
    • /
    • 2004
  • The shrinkage preliminary test ridge regression estimators (SPTRRE) based on Wald (W), Likelihood Ratio (LR) and Lagrangian Multiplier (LM) tests for estimating the regression parameters of the multiple linear regression model with multivariate Student's t error distribution are considered in this paper. The quadratic biases and risks of the proposed estimators are compared under both null and alternative hypotheses. It is observed that there is conflict among the three estimators with respect to their risks because of certain inequalities that exist among the test statistics. In the neighborhood of the restriction, the SPTRRE based on LM test has the smallest risk followed by the estimators based on LR and W tests. However, the SPTRRE based on W test performs the best followed by the LR and LM based estimators when the parameters move away from the subspace of the restrictions. Some tables for the maximum and minimum guaranteed efficiency of the proposed estimators have been given, which allow us to determine the optimum level of significance corresponding to the optimum estimator among proposed estimators. It is evident that in the choice of the smallest significance level to yield the best estimator the SPTRRE based on Wald test dominates the other two estimators.

AT91SAM7S256 ARM 칩을 이용한 UHF RFID R/W 단말기 개발 (Development of UHF RFID R/W System Using AT91SAM7S256 ARM Chip)

  • 황기현;장원태;한형래;손종훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1131-1132
    • /
    • 2008
  • In this paper, we developed UHF RFID R/W system using AT91SAM7S256(ARM chip), UHF RFID R/W module (WJ7090) and wireless LAN(IEEE 802.11.a/b). And we developed a transmission/receiving packet which is send to UHF R/W module in AT91SAM7S256. In order to show the usefulness of UHF RFID R/W system, we executed a performance test. The developed UHF RFID R/W system shows better performance for reading of RFID tag and data transmission through wireless LAN.

  • PDF

2500kW 용해설비 시운전 결과 및 5000kW 용해로용 인버터 설계 (The Result of 2500kW Induction Smelting System Trial Running and Basic Design of 5000kW Induction Smelting System)

  • 유효열;심은용;정대환;김상중;강재봉;강호현;김왕래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.288-291
    • /
    • 2006
  • The authors, R&D member of DAWONSYS and Soongsil University, are developing 5000kW smelting inverter system by 2007 under the sponsor from Korea Energy Management Corporation. As a part of the project, 2500kW inverter system has developed in 2005[6], and installed in real production site, and has been running for 7 months successfully. This report deals with the test result of 2500kW smelting inverter system and design for 5000kW smelting inverter system which is final target of this project.

  • PDF

디젤엔진용 소결(W/C35%Ni) 태핏의 마멸거동에 관한 연구 (A Study on Friction and Wear Characteristics of Sintered W/C-35%Ni Tappets for Diesel Engine Application)

  • 류병진;오세일;박맹로;양승호
    • Tribology and Lubricants
    • /
    • 제16권1호
    • /
    • pp.33-38
    • /
    • 2000
  • Abstract- In this paper tribological characteristics of solid and liquid phase sintered W/C-35%Ni tappets were investigated. Three test methods were performed to investigate the wear and surface damage mechanism of sintered tappets. First, block-on-ring wear test was performed to investigate the wear characteristics under pure sliding condition. Second, simplified cam and tappet tests (called component wear test hereafter) were carried out to simulate the real contact history of cam and tappet. Also, after the test, contact surfaces were analyzed with scanning electron microscope to study the wear mechanism. As a final screening, engine dynamo tests were performed. Results showed that in the block on ring sliding wear test, solid phase sintered specimens showed superior wear resistance to liquid phase sintered specimens. The component wear tests and engine dynamo tests also showed the same results. Therefore, in these tests, solid phase sintered tappet material revealed superior wear resistant properties to liquid phase sintered one.

TMS320C32를 이용한 한시 과전류 계전기의 구현 (Implementation of an Over-Current Relaying Algorithm with TMS320C32)

  • 유성록;윤병욱;박병우;최창영;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF

마이크로그리드용 10[kW] PCS 개발 및 성능시험 (The Development & Performance Test of 10[kW] Power Conditioning System for Microgrid)

  • 이학주;채우규;박중성;김주용;김찬영
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.55-62
    • /
    • 2011
  • PCS(Power Conditioning System) is the necessary component in Microgrid, composed of multiple distributed generators and energy storage system. In this paper, the functions of PCS are defined and 10[kW] PCS for PV and BESS are developed. To apply PCSs to Microgrid, this paper presents a 3-phase inverter with the decoupling current controller, voltage controller and DPLL control system. PCSs were applied to 120[kW] pilot plant and its performance tests were carried out. Test results of PCS at each operation mode show stable in Microgrid.