• Title/Summary/Keyword: W-W Test

Search Result 4,640, Processing Time 0.026 seconds

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

Study on Ejection Mitigation Impact Test about correlation between Vehicle and B.I.W(Body In White) Condition (FMVSS 226 Ejection Mitigation Impact Test의 시험품 단순화에 따른 인자들의 상관 관계에 대한 연구)

  • Kang, Mooncheol;Shin, Hyunhack;Oh, Hyungjoon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.4
    • /
    • pp.16-19
    • /
    • 2015
  • FMVSS226 Ejection Mitigation Impact Test is usually performed by real vehicle. But it is necessary to perform the test using by Reinforced B.I.W. with considering vehicle developing timing and roof rail airbag (RRAB) supplier capacity. We sometimes need tendency (quick data) instead of slow accurate data to fix RRAB design as proper timing. Test with Reinforced B.I.W. is helpful saving time and cost. But it should be confirmed how much different between vehicle conditioned test result and Reinforced B.I.W. conditioned test result. There are some points to be improved even in the test with vehicle. Understanding of deviation of Reinforced B.I.W. conditioned test result from vehicle conditioned test result is needed to get benefits with using Reinforced B.I.W. conditioned in the test.

Phonological Status of Korean /w/: Based on the Perception Test

  • Kang, Hyun-Sook
    • Phonetics and Speech Sciences
    • /
    • v.4 no.3
    • /
    • pp.13-23
    • /
    • 2012
  • The sound /w/ has been traditionally regarded as an independent segment in Korean regardless of the phonological contexts in which it occurs. There have been, however, some questions regarding whether it is an independent phoneme in /CwV/ context (cf. Kang 2006). The present pilot study examined how Korean /w/ is realized in $/S^*wV/$ context by performing some perception tests. Our assumption was that if Korean /w/ is a part of the preceding complex consonant like $/C^w/$, it should be more or less uniformly articulated and perceived as such. If /w/ is an independent segment, it will be realized with speaker variability. Experiments I and II examined the identification rates as "labialized" of the spliced original stimuli of $/S^*-V/$ and $/S^{w*}-^wV/$, and the cross-spliced stimuli $/S^{w*}-V/$ and $/S^*-^wV/$. The results showed that round qualities of /w/ are perceived at significantly different temporal point with speaker and context variability. We therefore conclude that /w/ in $/S^*wV/$ context is an independent segment, not a part of the preceding segment. Full-scale examination of the production test in the future should be performed to verify the conclusion we suggested in this paper.

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

A Study on the Marginal Fit of Dental Prosthesis According to the W/P Ratio of Investment (매몰재의 혼수비가 치관 보철물 변연의 적합성에 미치는 영향에 관한 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 1996
  • This test is verifying for influence of W/P ratio of investment upon dental prosthesis Firstly we made 40 MOD die and divide 4 groups, each group take 0.2 different w/p ratio grade such as 0.35, 0.37, 0.39 and 0.41. The method of data analysis applied were by ANOVA, Tukey test and Mann-Whiney and Kruskal Wallis test. The finding of this study were as follows : 1. The 0.37 w/p ratio group showed most accurte margin due to $15.8{\mu}m$ gap between margin and die which keep up with manufacture's instruction and 0.35 w/p ratio group was followed as second accuracy group o 새 $48.3{\mu}m$ gap between margin and die, 0.39 w/p ratio group showed $101{\mu}m$ gap and 0.41 w/p ratio group showed $129.8{\mu}m$ gap. 2. As to the relationship of the margin accuracy between 4 different grade of w/p ratio groups, each group was statistically significant(P<0.01). Also the all groups were statistically significant except between 0.35 and 0.37 groups between 0.39 and 0.41 groups, and between 0.35 and 0.39 groups. 3. A consequence of Mann-Whitney & Kruskal-Wallis test for marginal accuracy between 4 different grade of w/p ratio was statistically significant as same as above ANOVA test result. Also Tukey test for verifying similarity from each group showed same as above.

  • PDF

A study on the Reliability System Software based on NHPP(Non-Homogeneous Poisson Process (비-동질 안정 프로세스 기반 임베디드 시스템 소프트웨어의 신뢰성 특성에 관한 연구)

  • 한상섭;백영구;이근석;전현덕;류호중;이기서
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.347-358
    • /
    • 2001
  • In this paper, we apply NHPP model example to s/w process in order to get to know s/w reliability. The test is constructed by a test zig of commercial product loaded real embedded system s/w. It is established to s/w reliability prediction and estimation of real-time embedded system s/w. It is computed the prediction value of cumulative failures, the failure intensity, the reliability and the estimation value of MTTF, Failure Rate. To the more realization of high reliability in the real-time embedded system s/w, if the embedded system s/w is ensured to the test coverage and constructed to stable s/w process & operating system, we can improve the performance and the reliability characteristic of the real-time embedded system s/w.

  • PDF

Noise Test and Evaluation of a 750kW Wind Turbine Generator (750kW 풍력발전기의 소음실증)

  • Kim, Seock-Hyun;Heo, Wook;Lee, Hyun-Woo
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

High Temperature Compressive Properties of Tungsten Activated Sintered Pare Prepared by 0.4 wt.% Ni-doped Tungsten Powder Compacts (0.4 wt% Ni을 첨가한 W 활성소결체의 고온압축 특성 연구)

  • 이승익;김순욱;박영삼;문인형
    • Journal of Powder Materials
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2002
  • The high temperature deformation behavior of the activated sintered W powder compacts was investigated. The W compact showed the relative density of 94% with the average W grain size of $23\mutextrm{m}$ by activated sintering at $1400^{\circ}C$ for 1 hour. Compression tests were carried out in the temperature range of $900-1100^{\circ}C$ at the strain rate range of $10^{0}$/sec - $10^{-3}$/sec. True stress-strain curve and microstructure exhibited the grain boundary brittleness which was dependent on the compression test temperature. The activated sintered W compact showed that the maximum stress as well as the strain at the maximum stress was abruptly decreased as the test temperature increase from $900^{\circ}C$ to 1000 and $1100^{\circ}C$ regardless of the strain rate. The discrepancy of the microstructure in the specimen center was obviously observed with the increase of the test temperature. After compression test at $900^{\circ}C$ the W grain was severely deformed normally against the compression axis. However, after compression test at $1000^{\circ}C$ and $1100^{\circ}C$ the W grain was not deformed, but the microcrack was formed in the W grain boundary. The Ni-rich second phase segregated along the W grain boundary could be partly unstable over $900^{\circ}C$ and affect the poor mechanical property of the activated sintered W compact.

Effect of Nickel addition in DC arc test of Cu-W electrode (Cu-W 전극의 DC Arc 시험에 있어서 Nickel 첨가 영향)

  • Kim, Bong-Seo;Chung, Hyeon-Wook;Lee, Hee-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.11-14
    • /
    • 2003
  • Sintered Cu-W has been used for the electrode of GIS for interrupting the abnormal current. In this study the effect of Ni addition in Cu-W electrode was investigated. Cu-W electrodes used contains 0.1~0.2wt% Ni and were conducted the experiments which was attacked by DC arc test (70V-70A) for 300 times periodically. As the contents of Ni in Cu-W electrode increase, the hardness and electrical conductivity were decreased. The weight change ($\Delta$mg) of electrode after DC arc test increased with increasing Ni contents and test times. The hardness and electrical conductivity of electrode after DC arc test were decreased compared with non-arc affected electrode, which was owing to the defects near surface of electrode and degradation by arc heat. It was considered that Cu in the Cu-W electrode was scattered to all directions by arc heat, therefore, the electrodes were damaged and deformed in the surface and cross-section of electrode. It is difficult to estimate directly the characteristics of Cu-W electrode for GIS related with high voltage and current from the results of DC arc test conducted in this study. However, the results of the effect of Ni addition in Cu-W electrode could be applied for the research of electrode for GIS.

  • PDF

SITAT: Simulation-based Interface Testing Automation Tool for Robot Software Component (로봇 소프트웨어 컴포넌트를 위한 시뮬레이션 기반 인터페이스 테스팅 자동화 도구)

  • Kang, Jeong-Seok;Choi, Hyeong-Seob;Maeng, Sang-Woo;Kim, Si-Wan;Park, Hong-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.6
    • /
    • pp.608-616
    • /
    • 2010
  • Robot software components can be categorized into two types; the pure S/W component and the H/W-related one. Since interface testing of the robot software component is the labour-intensive and complicated work, an effective automated testing tool is necessary. Especially it is difficult to test all types of H/W-related components because it is hard work to prepare all H/W modules related to them. This paper proposes a new simulation-based interface testing automation tool(SITAT) which generates automatically test cases for interface testing of the robot software component and executes the interface test with the generated test cases where the simulator is used for simulation of the activity of a H/W module instead of the real H/W module. This paper verifies the effectiveness of the suggested SITAT with testing of the real H/W-related robot software component.