• Title/Summary/Keyword: W code

Search Result 741, Processing Time 0.031 seconds

Backward Channel Protection Method For RFID Tag Security in the Randomized Tree Walking Algorithm (랜덤화된 트리워킹 알고리즘에서의 RFID 태그 보안을 위한 백워드 채널 보호 방식)

  • Choi Wonjoon;Roh Byeong-hee;Yoo S. W.;Oh Young Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.5C
    • /
    • pp.415-421
    • /
    • 2005
  • Passive RFID tag does not have its own power, so it has very poor computation abilities and it can deliver signals in very short range. From the facts, most RFID Tag security schemes assumed that the backward channel from tags to a reader is safe from eavesdropping. However, eavesdroppers near a tag can overhear message from a tag illegally. In this paper, we propose a method to protect the backward channel from eavesdropping by illegal readers. The proposed scheme can overcome the problems of conventional schemes such as randomized tree walking, which have been proposed to secure tag information in tree-walking algorithm as an anti-collision scheme for RFID tags. We showed the efficiency of our proposed method by using an analytical model, and it is also shown that the proposed method can provide the probability of eavesdropping in some standardized RFID tag system such as EPCglobal, ISO, uCode near to '0'.

Prediction of Lift Performance of Automotive Glass Using Finite Element Analysis (유한요소해석을 통한 자동차용 글라스의 승강성능 예측)

  • Moon, Hyung-Il;Kim, Heon-Young;Choi, Cheon;Lee, In-Heok;Kim, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1749-1755
    • /
    • 2010
  • The performance of power window system was decided by driving characteristics of the window regulator part and reaction by the glass run. The performance of power window system usually has been predicted by experimental methods. In this paper, an analytical method using the explicit code was suggested to overcome the limit of the experimental methods. The friction coefficient of glass run was obtained by the friction test at various conditions and the Mooney-Rivlin model was used. Also, a mechanism of window regulator consisted of the fast belt system and the slip ring elements. And, we conducted the analysis considering characteristic of a motor and obtained the lifting speed of automotive glass with high reliability

A Study of Ozone Generation Characteristic using Ceramic Catalyst Tube of Ti-Si-Al (Ti-Si-Al형 세라믹 촉매 방전관의 오존 발생 특성 연구)

  • 조국희;김영배;이동훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.130-136
    • /
    • 2002
  • A novel ozonizer has been developed using a high frequency surface discharge and a high purity Ti-Si-Al ceramic catalyst as its dielectric component. A cylindrical thin compound ceramic catalyst in reactor is adhered to inside of the film-like outside electrode. And, when experiment condition are oxygen gas temperature of 20 [$^{\circ}C$], inner reactor pressure of 1.6 atm 600[Hz] and flow late of 2[l/min]. the ozonizer can easily produce ozone concentration(50~60[g/㎥]for oxygen) and power efficiency(180[g/kWh]for oxygen) without using a special enrichment means. At 2[l/min], 20[$^{\circ}C$], 1.6[atm], 600[Hz]and 40[W], the result of simulation to gas temperature of reactor using general code Phoenics, the maximum temperature of reactor was 132[$^{\circ}C$]in reactor. Ant the result electric field simulation of Ti-Si-Al type reactor using general code Flux 2D, maximum electric field was 0.131E.08[V/m].

Development of stability maps for flashing-induced instability in a passive containment cooling system for iPOWER

  • Lim, Sang Gyu;No, Hee Cheon;Lee, Sang Won;Kim, Han Gon;Cheon, Jong;Lee, Jae Min;Ohk, Seung Min
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.37-50
    • /
    • 2020
  • A passive containment cooling system (PCCS) has been developed as advanced safety feature for innovative power reactor (iPOWER). Passive systems are inherently less stable than active systems and the PCCS encountered the flashing-induced instability previously identified. The objective of this study is to develop stability maps for flashing-induced instability using MARS (Multi-dimensional Analysis of Reactor Safety) code. Firstly, we conducted a series of sensitivity analysis to see the effects of time step size, nodalization, and alternative MARS user options on the onset of flashing-induced instability. The riser nodalization strongly affects the prediction of flashing in a long riser of the PCCS, while time step size and alternative user options do not. Based on the sensitivity analysis, a standard input and an analysis methodology were set up to develop the stability maps of PCCS. We found out that the calculated equilibrium quality at the exit of the riser as a stability boundary above 5 kW/㎡ was approximately 1.2%, which was in good agreement with Furuya's results. However, in case of a very low heat flux condition, the onset of instability occurred at the lower equilibrium quality. In addition, it was confirmed that inlet throttling reduces the unstable region.

Smart-tracking Systems Development with QR-Code and 4D-BIM for Progress Monitoring of a Steel-plant Blast-furnace Revamping Project in Korea

  • Jung, In-Hye;Roh, Ho-Young;Lee, Eul-Bum
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.149-156
    • /
    • 2020
  • Blast furnace revamping in steel industry is one of the most important work to complete the complicated equipment within a short period of time based on the interfaces of various types of work. P company has planned to build a Smart Tracking System based on the wireless tag system with the aim of complying with the construction period and reducing costs, ahead of the revamping of blast furnace scheduled for construction in February next year. It combines the detailed design data with the wireless recognition technology to grasp the stage status of design, storage and installation. Then, it graphically displays the location information of each member in relation to the plan and the actual status in connection with Building Information Modeling (BIM) 4D Simulation. QR Code is used as a wireless tag in order to check the receiving status of core equipment considering the characteristics of each item. Then, DB in server system is built, status information is input. By implementing BIM 4D Simulation data using DELMIA, the information on location and status is provided. As a feature of the S/W function, a function for confirming the items will be added to the cellular phone screen in order to improve the accuracy of tagging of the items. Accuracy also increases by simultaneous processing of storage and location tagging. The most significant effect of building this system is to minimize errors in construction by preventing erroneous operation of members. This system will be very useful for overall project management because the information about the position and progress of each critical item can be visualized in real time. It could be eventually lead to cost reduction of project management.

  • PDF

Development of Backup Calculation System for a Nuclear Steam Supply System Thermal-Hydraulic Model ARTS (Advanced Real-time Thermal Hydraulic Simulation) of the W/H Type NPP (W/H형 원전 시뮬레이터용 핵 증기공급 계통 열수력모델 ARTS(Advanced Real-time Thermal Hydraulic Simulation)의 보조계산체계 개발)

  • 서재승;전규동
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The NSSS (Nuclear Steam Supply System) thermal-hydraulic programs adopted in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited compulsational capability at that time, they usually used very simplified physical models for a real-time simulation of NSSS thermal-hydraulic transients, which entails inaccurate results and, thus, the possibility of so-called "negative training", especially for complicated two-phase flows in the reactor coolant system. In resolve the problem, KEPRI developed a realistic NSSS T/H program ARTS which was based on the RETRAN-3D code for the improvement of the Nuclear Power Plant full-scope simulator. The ARTS (based on the RETRAN-3D code) guarantees the real-time calculations of almost all transients and ensures the robustness of simulations. However, there is some possibility of failing to calculate in the case of large break loss of coolant accident (LBLOCA) and low-pressure low-flow transient. In this case, the backup calculation system cover automatically the ARTS. The backup calculation system was expected to provide substantially more accurate predictions in the analysis of the system transients involving LBLOCA. The results were reasonable in terms of accuracy, real-time simulation, robustness and education of operators, complying with FSAR and the AMSI/ANS-3.5-1998 simulator software performance criteria.

Efficient Policy for ECC Parity Storing of NAND Flash Memory (낸드플래시 메모리의 효율적인 ECC 패리티 저장 방법)

  • Kim, Seokman;Oh, Minseok;Cho, Kyoungrok
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.477-482
    • /
    • 2016
  • This paper presents a new method of parity storing for ECC(error correcting code) in SSD (solid-state drive) and suitable structure of the controller. In general usage of NAND flash memory, we partition a page into data and spare area. ECC parity is stored in the spare area. The method has overhead on area and timing due to access of the page memory discontinuously. This paper proposes a new parity policy storing method that reduces overhead and R(read)/W(write) timing by using whole page area continuously without partitioning. We analyzed overhead and R/W timing. As a result, the proposed parity storing has 13.6% less read access time than the conventional parity policy with 16KB page size. For 4GB video file transfer, it has about a minute less than the conventional parity policy. It will enhance the system performance because the read operation is key function in SSD.

The Software Complexity Estimation Method in Algorithm Level by Analysis of Source code (소스코드의 분석을 통한 알고리즘 레벨에서의 소프트웨어 복잡도 측정 방법)

  • Lim, Woong;Nam, Jung-Hak;Sim, Dong-Gyu;Cho, Dae-Sung;Choi, Woong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.153-164
    • /
    • 2010
  • A program consumes energy by executing its instructions. The amount of cosumed power is mainly proportional to algorithm complexity and it can be calculated by using complexity information. Generally, the complexity of a S/W is estimated by the microprocessor simulator. But, the simulation takes long time why the simulator is a software modeled the hardware and it only provides the information about computational complexity quantitatively. In this paper, we propose a complexity estimation method of analysis of S/W on source code level and produce the complexity metric mathematically. The function-wise complexity metrics give the detailed information about the calculation-concentrated location in function. The performance of the proposed method is compared with the result of the gate-level microprocessor simulator 'SimpleScalar'. The used softwares for performance test are $4{\times}4$ integer transform, intra-prediction and motion estimation in the latest video codec, H.264/AVC. The number of executed instructions are used to estimate quantitatively and it appears about 11.6%, 9.6% and 3.5% of error respectively in contradistinction to the result of SimpleScalar.

Analysis of Technology Convergence Structure Using technology Input-output Analysis: Case of Convergence R&D Development Project for Small and Medium Businesses (기술연관분석을 활용한 기술융합구조 분석: 중소기업 융·복합기술개발사업 사례)

  • Lee, Kwang-Min;Kim, Da-Woon;Hong, Jae-Bum
    • Journal of Technology Innovation
    • /
    • v.22 no.3
    • /
    • pp.1-35
    • /
    • 2014
  • This study analyzed convergence status among input technologies used in technology development with Technology I-O analysis. It was another version of industry input-output analysis which is used in technology planning. This case is an analysis of association between technology an product. The subjects of analysis were 401 tasks that applied to '2012 Convergence Technology Development Project for Small and Medium Businesses' promoted by Korea Technology & Information Promotion Agency for Small and Medium Enterprises. The process of analysis is as followed. First step, we made a matrix table as an input of technology input-output analysis. Input was defined by technology and output was defined by the product. Input technology was defined in a 3-digit code under National Science Technology Classification and output products were defined in a 5-digit under National Standard Industry Code. Second, the Spillover ratio among technologies were calculated and was used to make a picture of technology linkage. As a result of analysis, technology spillover of embedded S/W was the highest in IT convergence, mold product in ET convergence, and functional cosmetics development technology in BT convergence. In general, IT convergence had many element technologies with high technology spillover, and ET had a small number of element technologies with high technology spillover. Therefore, investment effect of element technology is expected to be large if investment on element technologies with high technology spillover is important for vitalizing convergence.

A Study on the Safety Code Development of Gas Engine Micro Combined Heat and Power System (소형 가스엔진 열병합 발전시스템 안전기준 개발)

  • Kwon, Jun-Yeop;Kim, Min-Woo;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2021
  • Recently, as a solution to the sharp drop in "power reserve ratio", it is being converted to a microgrid that enables bi-directional transmission and distribution. A microgrid is composed of a small-scale distributed power supply and a load. As a representative technology of distributed power generation, there is a Micro Combined Heat and Power system applied to homes and buildings. In this study, a safety standard was developed by dividing the power generation system, cooling system, lubrication system, and exhaust system to derive safety standards for a small gas engine power generation system with a gas consumption less than 232.6kW (200,000 kcal/h). In the case of the power generation system, a filter was installed and the system was stopped by detecting gas leakage and abnormalities in engine speed or output and the cooling system is stipulated to stop the system in case of insufficient cooling water or overheating. The lubrication system monitors the pressure and temperature of the lubricating oil and stops the system when an abnormality occurs, and the exhaust gas emission concentration regulation value was specified in accordance with domestic and foreign standards. Through the results of this study, it is judged that the safety of the gas engine power generation system can be improved and it can contribute to the commercialization of products.