• Title/Summary/Keyword: Vp-p

Search Result 296, Processing Time 0.023 seconds

Low-Voltage CMOS Analog Four-Quadrant Multiplier (저전압 CMOS 아날로그 4상한 멀티플라이어)

  • 유영규;박종현;최현승;김동용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.84-88
    • /
    • 2000
  • In this paper, a low voltage CMOS analog four-quadrant multiplier is presented. The proposed multiplier is composed of two fully differential transconductors and lowers supply voltage down to VT+2VDS,sat+VDS,triode. The designed analog four-quadrant multiplier has simulated by HSPICE using 0.25㎛ n-well CMOS process with a 1.2V supply voltage. Simulation results show that the THD can be 1.28% at maximum differential input of 0.7VP-P.

  • PDF

10Gbps Time-Division Multiplexer using SiGe HBT (SiGe HBT를 이용한 10Gbps 시분할 멀티플렉서 설계)

  • 이상흥;강진영;송민규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.201-208
    • /
    • 2000
  • In the transmitter of optical communication systems, a time-division multiplexer combines several parallel data streams into a single data stream with a high bit rate. In this paper, we design a 4:1 (4-channels) time-division multiplexer using SiGe HBT with emitter size of 2x8um2. The operation speed is 100bps, the rise and fall times of 20-80% are 34ps and 34ps, respectively and the dissipation of power is 1.50W.

  • PDF

Design of Wide Input Range Multiple Filter-Banks for Analog Cochlear Chip (입력 신호범위가 넓은 아날로그 다중필터의 설계)

  • Choi, B.K.;Lee, K.;Ryu, S.T.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2613-2615
    • /
    • 2001
  • 청각시스템의 저전력 및 가격의 저렴화를 위해 달팽이관의 BM(Basilar Membrain)모델을 아날로그 VLSI 마이크로 파워 공정으로 구현하고 있다. 본 논문에서는 소리의 주파수 정보 추출기능을 하는 직렬 연결된 트리구조(TSBF : Tree-structured Cascaded Bandpass Filter)의 16채널의 아날로그 중간대역통과 필터회로를 CMOS VLSI 공정을 이용하여 설계하였다. 특히 큰 입력 신호에 대해서도 파형왜곡 없이 선형적인 특성을 가지는 트랜스 컨턱터를 이용하여 필터를 구현하였다. 필터는 저대역통과필터와 출력이득의 감쇄를 줄이기 위해서 중간대역통과필터를 이용하여 전체 시스템을 설계했다. 본 논문에서 기존의 150mVp-p 입력신호 범위의 트랜스 컨턱터를 Substrate 입력을 가지는 트랜스 컨턱터를 이용하여 입력신호 범위를 1Vp-p 까지 늘였다.

  • PDF

Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography (Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy (동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로)

  • Cho, Hyun-Seung;Park, Sun-Hyeong;Kang, Da-Hye;Lee, Kang-Hwi;Kang, Seung-Jin;Han, Bo-Ram;Oh, Jung-Hoon;Lee, Hae-Dong;Lee, Joo-Hyeon;Lee, Jeong-Whan
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • TThis study explored the requirement of fabric sensor that can measure the motion of the joint effectively by measuring and analyzing the variation in electric resistance of a sensor in accordance with bending and stretching motion of the arm by the implementation of a motion sensor utilizing conductive fabric. For this purpose, on both sides of two kinds of knitted fabric, namely 'L' fabric and 'W' fabric Single Wall Carbon Nano-Tube(SWCNT) was coated, fabric sensor was developed by finishing them in a variety of ways, and the sensor was attached to the arm band. The fabric sensor consisted of total 48 cases, namely background fabric for coating, the method of sensor attachment, the number of layer of sensors, the length of sensor, and the width of sensor. The performance of fabric motion sensors in terms of a dummy arm, that is, a Con-Trex MJ with 48 arm bands around it was evaluated. For each arm band, a total of 48, fastened around the dummy arm, it was adjusted to repeat the bending and stretching at the frequency : 0.5Hz, ROM : $20^{\circ}{\sim}120^{\circ}$, the voltage was recorded for each case after conducting three sets of repeat measurement for a total of 48 cases. As a result of the experiment, and as a consequences of the evaluation and analysis of the voltage based on the uniformity of the base line of the peak-to-peak voltage(Vp-p), the uniformity of Vp-p within the same set, and the uniformity of the Vp-p among three sets, the fabric sensors that have been configured in SWCNT coated 'L' fabric / welding / two layers / $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$, and SWCNT coated 'W' fabric / welding / two layers / $50{\times}10mm$ exhibited the most uniform and stable signal value within 5% of the total variation rate. Through all these results of the experiment, it was confirmed that SWCNT coated fabric was suitable for a sensor that can measure the human limb operation when it was implemented as a fabric sensor in a variety of forms, and the optimal sensor types were identified.

Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method (유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발)

  • Park, Won-Pil;Woo, Dae-Gon;Ko, Chang-Yong;Lee, Qyoun-Jung;Lee, Yong-Heum;Choi, Seo-Hyoung;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.130-139
    • /
    • 2007
  • The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

Characterization of Acute Hepatitis Virus A Genotype in Korea (국내 급성 A형 간염 바이러스의 유전자형 특징)

  • Kim, Mi Hyun;Choi, Hayana;Pak, Kun Sik;Seong, Chi Nam;Cho, Hyun Wook
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 2013
  • In Korea, most hepatitis A virus is the IA genotype, but reports of other genotypes have increased recently. Therefore, the purpose of this study is to conduct a genotypic analysis of acute hepatitis A virus. From April 2010 to April 2011, clinical specimens from 20 patients hospitalized with acute hepatitis A and 36 sera positive for anti-HAV IgM were obtained, and the genotype of the VP1/P2A region was analyzed. RNA sequences of the VP1/P2A junction region were amplified using RT-PCR, and the sequences were compared. From 50 sequences amplified, 4 sequences (8%) belonged to genotype IA. The remaining 46 (92%) belonged to genotype IIIA. The results indicate that the genotype of the hepatitis A virus has changed from IA to IIIA in Korea.

A study of beam hardening effect reduction occur in brain CT (Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구)

  • Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8479-8486
    • /
    • 2015
  • This study aim is occur in brain CT cause of beam hardening effect and reducing method, We will scan Bone opaque bead phantom on variation of image on the influence factor with equipment called 'Samatom Senation 16' with following listed herein : tube voltage, tube current, slice thickness, gantry angle, base line which affect beam-hardening effect. After that we are going to start Quantitative Analysis resulted in previous scanning and Qualitative Assessment with CT image sheet evaluation. result of quantitative analysis 140kVp $31.56{\pm}2.89HU$ on tube voltage, 150mA $-3.87{\pm}0.12HU$ on tube current, 3mm on slice thickness, and $13.31{\pm}1.03HU$ IOML on gantry angle which was the least beam-hardening effect. Like Qualitative Analysis, we went through Qualitative Assessment and most of valuers got a result of 140kVp on tube voltage, 150mA on tube current, 3mm on slice thickness. As before valuers evaluated gantry angle that scanned image from IOML or OML was the least beam-hardening effect occured. There are meaningful differences when we compare all theses factors statistically(P<0.05). therefore We consider that Minimizing artifact that caused by beam-hardening effect can provide better quality of image to deciphers and patients. if we rise tube voltage in permissible dose limit, set tube current in a limit that does not effect to image quality, use slice thickness too thin enough to harm resolution, use IOML or OML on gantry angle.

Crustal structure of the Korean peninsula (한반도 지각 속도구조)

  • Kim, Ki-Young;Hong, Myung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.12a
    • /
    • pp.43-51
    • /
    • 2007
  • In order to investigate the velocity structure of the southern part of the Korean peninsula, exploded seismic signals were recorded for 120 s along a 294-km WNW-ESE line and 150 s along a 335-km NNW-SSE line in 2002 and 2004, respectively. Velocity tomograms were derived from inverting P-wave and S-wave first arrival times. The raypaths indicate several midcrust interfaces. The shallowest one is at the approximate depth of $2{\sim}3\;km$ with refraction velocities of approximately Vp=6.0 and Vs=3.5 km/s, respectively. The second one of $15{\sim}17\;km$ depth has refraction velocities of approximately Vp=7.1 and Vs=3.7 km/s, respectively. The deepest significant interface varies in depth from 30.8 km to 36.1 km. The critically refracting Vp of $7.8{\sim}8.1\;km/s$ and Vs of $4.2{\sim}4.6\;km/s$ along this interface which may correspond to the Moho discontinuity. The velocity tomograms show (1) existence of a low-velocity zone centered at $6{\sim}7\;km$ depth under the Okchon fold belt and the Yeongnam massif, (2) extension of the Yeongdon fault down to greater than 10 km, and (3) existence of high-velocity materials under the Gyeongsan basin less than 4.2 km thick.

  • PDF

Structure and physical properties of Earth Crust material in the Middle of Korean Peninsula(2) : Comparison between elastic Velocity and point-load of core specimen of sedimentary rocks. (한반도 중부권 지각물질의 구조와 물성연구(2) : 퇴적암류 코아시료의 탄성파 속도와 점재하 강도 비교)

  • 송무영;황인선
    • The Journal of Engineering Geology
    • /
    • v.3 no.1
    • /
    • pp.21-37
    • /
    • 1993
  • In order to investigate the correlation of sedimentary rock properties. specific gravity, porosity, water content, sonic wave velodty, and point4oad strength index of core samples of limestones, sandstones and shales were measured. The relationships between density and velocity show $V_p=16300d-38719.3,{\;}V_s1896.4d-29225.1$ of regression equation for sandstones and $Vp=4085d-10264.8,{\;}V_s=3519d-7841.3$ for shales and <$Vp=4085d^2-20747d+303,{\;}V_s=3899d^2-21442d+318$ for limestones. Seismic wave velocity of shales which have high density is lower than that of sandstones, and this seems to be an effect of bedding in shale. P-wave velocity and S-wave velocity of limestones, sandstones and shales show the linear relationships as a whole. The regression equations are respectively calculated V_s=0.26V_p+1041.6m/sec,{\;}V_s=0.43V_p+424.2m/sec,{\;}and{\;}Vs=0.51V_p+261.9m/sec$ and the correlation coefficients of the velocity show r= 0.86 in sandstones, r= 0.75 in limestones and r=0.86 in shales. According to the point4oad strength test for limestones, point4ord strength anisotropy was not so dear even though the specimens show generally the banded structure. Variations of dip angle of bedding whihin the range $30^{\circ}-60^{\circ}$ does not have much influence upon the diametral strength index and axial strength index. From the result of point load test, P-wave velocity increases with point4ord strength index but the regression equations are $V_p=98.5lI{s_d}+4082.1m/sec,{\;}V_p=106.41{s_a}+3954m/sec$ and their correlation coefficient is low.

  • PDF