• 제목/요약/키워드: Vortex Generators

검색결과 58건 처리시간 0.024초

종방향 와동이 유체유동 및 열전달 특성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Fluid Flow and Heat Transfer Characteristics by the Longitudinal Vortices)

  • 양장식;김은필
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.843-852
    • /
    • 2000
  • The flow characteristics and the heat transfer rate on a surface by interaction of a pair of vortices were studied experimentally. The test facility consisted of a boundary-layer wind tunnel with a vortex introduced into the flow by half-delta winglet protruding from the surface. In order to control the strength of the longitudinal vortices, the angles of attack of the vortex generators were varied from $\pm20\;degree\;to\;\pm45$ degree, but spacings between the vortex generators were fixed to 4 cm. The 3-dimensional mean velocity measurements were made using a five-hole pressure probe. Heat transfer measurements were made using the thermochromatic liquid to provide the local distribution of the heat transfer coefficient. By using the method mentioned above, the following conclusions were obtained from the present experiment. The boundary layer was thinned in the regions where the secondary flow was directed toward the wall and thickened where it was directed away from the wall. The peak augmentation of the local heat transfer coefficient occurred in the downwash region near the point of minimum boundary-layer thickness.

  • PDF

Energy-efficient flow control around blunt bodies

  • Yurchenko, Nina F.
    • Advances in aircraft and spacecraft science
    • /
    • 제1권1호
    • /
    • pp.15-25
    • /
    • 2014
  • The developed concept of smart flow control based on turbulence scale modification was applied to control a flow around a circular cylinder. The concept was realized using arrays of vortex-generators regularly spaced along a cylinder generatrix with a given step. Mechanical and thermal vortex-generators were tested, the latter having been based on the localized surface heating or plasma discharges initiated with microwave radiation near the surface. Thus depending on a particular engineering solution, flow transport properties could be modified in passive or active ways. Matched numerical and experimental investigations showed a possibility to delay flow separation and, accordingly, to improve the aerodynamic performance of blunt bodies.

Plate Fin-Oval Tube 열교환기에서 익형 와류발생체에 의한 Fin 표면에서의 국소 열전달에 대한 특성 (Local Heat Transfer Characteristics on Fin Surface of Plate Fin-Oval Tube with Delta Wing Vortex Generators)

  • 신석원;정인기;김수연
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.757-766
    • /
    • 2009
  • In the present study, the effect of delta-wing vortex generators(DWVG) on the local heat transfer of the plate fin-oval tube was experimentally analyzed for Reynolds numbers for 2000, 2500 and 3200. The local heat transfer coefficient of the fin surface for four type DWVGs was measured by the naphthalene sublimation technique. As the results, the distribution of the heat transfer coefficient at rear of DWVGs showed longitudinal contours for common flow down DWVGs and wavy contours for common flow up DWVGs. The distribution showed many cell type contours at near wall and downstream for all DWVGs. Compared to case without DWVGs in present experimental tests, all DWVGs showed the best enhancement of heat transfer at Re=2000. Of 4 cases of DWVGs, D type showed the best enhancement of heat transfer.

개량 루버핀에 의한 열전달 성능향상에 관한 연구 (Numerical Analysis on the Heat Transfer Enhancement by Modified Lovour Fin)

  • 정재동;박병규;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.408-413
    • /
    • 2001
  • Numerical analysis on the three-dimensional laminar flows (Re=1000) and heat transfer in a rectangular channel with punched longitudinal vortex generator have been conducted to explore the heat transfer enhancement and the combined effect of the angle of attack ${\alpha}$ and the lovour angle ${\beta}$. Rectangular winglets have been used as vortex generators. Velocity and temperature fields and spanwise averaged Nu and friction factor were presented. Enhancement of heat transfer and flow loss penalty are evidenced. The results show performance characteristics allowing a reduction in heat transfer surface area of 62% for fixed heat duty and for fixed pumping power compared with that of channel flow without vortex generator. However, adding lovour angle to the vortex generator shows no positive effect on the heat transfer enhancement.

  • PDF

와동간의 상호작용이 경계층 및 열전달에 미치는 영향에 관한 연구 ( II ) - Common flow up에 관하여 - (An Experimental Study on the Effects of the Boundary Layer and Heat Transfer by Vortex Interactions ( II ) - On the common flow up -)

  • 한동주;양장식;이기백
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.298-305
    • /
    • 2000
  • The flow characteristics and the heat transfer rate on a surface by interaction of a pair of vortices were studied experimentally. The test facility consisted of a boundary-layer wind tunnel with a vortex introduced into the flow by half-delta wings protruding from the surface. In order to control the strength of the longitudinal vortices, the angles of attack of the vortex generators were varied from - 20 degree to - 45 degree, but spacings between the vortex generators were fixed to 4 cm. The 3-dimensional mean velocity measurements were made using a five-hole pressure probe. Heat transfer measurements were made using the thermochromatic liquid to provide the local distribution of the heat transfer coefficient. Unlike common flow down, common flow up vortices moved toward the centerline as they developed and interacted strongly with each other but not with the boundary layer. Spanwise profiles of Stanton number were similar for ${\beta}=-20^{\circ}\;and\;-35^{\circ}$, but not similar for ${\beta}=-45^{\circ}$. The case of ${\beta}=-20^{\circ}\;and\;-35^{\circ}$ showed the two peak Stanton number, but the case of ${\beta}=-45^{\circ}$ showed the only one peak Stanton number.

Advances In Air-Cooled Heat Exchanger Technology for Residential Air-Conditioning

  • Webb Ralph L.;Kim Nae-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.184-195
    • /
    • 2005
  • This paper describes the recent work on advanced technology concepts applied to air cooled heat exchangers for residential air-conditioning. The concepts include vortex generators for the air-side, micro-fin or flat tubes for the refrigerant-side. Advances in understanding of heat transfer mechanisms, predictive models are discussed.

단일 유로를 갖는 와류발생기의 에너지분리 특성 (Energy Separation Characteristics of Single Hole Vortex Generator)

  • 유갑종;장준영;최인수
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1005-1012
    • /
    • 2001
  • When vortex tubes are applied to enhance the coefficient of performance of refrigeration system, the smaller one is preferable. However, the existing vortex generator with a nozzle hole diameter of 0.5mm was not suitable due to chocking of the nozzle hole. Therefore, experimental investigation was made to find an appropriate geometry of vortex generator, which could give a comparable effect of energy separation to commercial ones without chocking problem. The tested vortex generators were tangential and spiral types, which had single inducing channel with larger cross-sectional area than that of conventional multi-hole ones. The experimental result showed that the performance of the spiral type was better than that of the tangential one. As a small size of spiral one, the diameter of cold-end orifice is proposed to an half of tube diameter for the application to refrigeration system, while cold mass fraction ratio is 0.5∼0.6 for a desirable operation.

Vortex에 의한 DSI공정 중 혼합효율 향상에 관한 연구 (A Numerical Study of $SO_2$ Efficiency Improvement in the DSI process of FGD)

  • 정진도;김장우
    • 한국분무공학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2009
  • This study carried out numerical analysis of flow field of combustion gas and sorbent to test sorbent efficiency of DSI process. To provide rapid mixing for increase utilization rate of sorbent, streamwise vorticity can be introduced into the flowing streams by other means; for example, by installing vortex generators immediately downstream of the wavy trailing edge. Computing results show that the degree of sorbent dispersion depends strongly on duct structure. Highest dispersion efficiency received when vortex generator was installed inside of duct. The results presented in this study a optimum condition for the development of practical DSI process.

  • PDF

와동 발생기 높이 변화에 대한 경계층 내의 유동장과 온도장에 관한 실험적 연구 (The Experimental Study of the Interaction Between the Flow rind Temperature Field and a Boundary Layer Due to a Variety of tole Height of a Vortex Generator)

  • 권수인;양장식;이기백
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.82-93
    • /
    • 2002
  • The effects of the interaction between the flow and temperature field and a boundary layer due to a variety of the height of a vortex generator are experimentally investigated. The test facility consists of a boundary-layer wind tunnel with the vortex generator protruding from the bottom surface. In order to control the strength of the longitudinal vortices, the angle of attack and the spacing distance of the vortex generator are 20 degree and 40 mm, respectively. The height of the vortex generator (H) is 15 mm, 20 mm and 30 mm and the cord length of it is 50 mm. Three-component mean velocity measurements are made using a 5-hole probe system and the surface temperature distribution is measured by the hue capturing method using thermochromatic liquid crystals. By using the method mentioned above, the following conclusions are obtained from the present experiment. The boundary layer is thinned in the downwash region where the strong downflow and the lateral outflow of the boundary layer fluid occur and thickened in the upwash re,3ion where the longitudinal vortex sweeps low momentum fluid away from the bottom surface. In case that the height of the vortex generator increases, the averaged circulation and the maximum vorticity of the vortex pair decrease. The contours of the non-dimensional temperature show the similar trends fur all the cases (H=15 mm, 20 mm and 30 mm). The peak augmentation of the distribution of the local non-dimensional temperature occurs in the downwash region near the point of minimum boundary-layer thickness.

스마트 무인기 TR-S2 형상의 정적 풍동시험 (Static Wind Tunnel Test of Smart Un-manned Aerial Vehicle(SUAV) for TR-S2 Configuration)

  • 최성욱;조태환;정진덕
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.755-762
    • /
    • 2005
  • To evaluate the aerodynamic efficiency of TR-S2 configuration designed by SUDC, wind tunnel tests of $40\%$ scaled model were done in KARI LSWT. The aerodynamic characteristics of plain and Semi-Slotted Flaperon were compared, and vortex generators were installed to improve flow pattern along the wing surface. Effects of the control surface such as elevator, rudder, aileron, and incidence angle of horizontal tail are measured for various testing conditions. Test results showed that Semi-Slotted Flaperon produced more favorable lift, lift/drag, and stall margins and application of vortex generator would be best choice to enhance wing performance. Longitudinal, lateral and directional characteristics of TR-S2 were found to be stable for the pitch and yaw motions.