• 제목/요약/키워드: Volumetric imaging

검색결과 131건 처리시간 0.025초

3D Visualization of Partially Occluded Objects Using Axially Distributed Image Sensing With a Wide-Angle Lens

  • Kim, Nam-Woo;Hong, Seok-Min;Lee, Hoon Jae;Lee, Byung-Gook;Lee, Joon-Jae
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.517-522
    • /
    • 2014
  • In this paper we propose an axially distributed image-sensing method with a wide-angle lens to capture the wide-area scene of 3D objects. A lot of parallax information can be collected by translating the wide-angle camera along the optical axis. The recorded wide-area elemental images are calibrated using compensation of radial distortion. With these images we generate volumetric slice images using a computational reconstruction algorithm based on ray back-projection. To show the feasibility of the proposed method, we performed optical experiments for visualization of a partially occluded 3D object.

Automatic Volumetric Brain Tumor Segmentation using Convolutional Neural Networks

  • Yavorskyi, Vladyslav;Sull, Sanghoon
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.432-435
    • /
    • 2019
  • Convolutional Neural Networks (CNNs) have recently been gaining popularity in the medical image analysis field because of their image segmentation capabilities. In this paper, we present a CNN that performs automated brain tumor segmentations of sparsely annotated 3D Magnetic Resonance Imaging (MRI) scans. Our CNN is based on 3D U-net architecture, and it includes separate Dilated and Depth-wise Convolutions. It is fully-trained on the BraTS 2018 data set, and it produces more accurate results even when compared to the winners of the BraTS 2017 competition despite having a significantly smaller amount of parameters.

  • PDF

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

3차원 생물체 가시화 모델 구축장치 개발 및 성능평가 (Development and Evaluation of System for 3D Visualization Model of Biological Objects)

  • 황헌;최태현;김철수;이수희
    • Journal of Biosystems Engineering
    • /
    • 제26권6호
    • /
    • pp.545-552
    • /
    • 2001
  • Nondestructive methods such as ultrasonic and magnetic resonance imaging systems have many advantages but still much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct a biological object to obtain interior and exterior informations, 3D image visualization model from a series of sliced sectional images gives more useful information with relatively low cost. In this paper, a PC based automatic 3D visualization system is presented. The system is composed of three modules. The first module is the handling and image acquisition module. The handling module feeds and slices a cylindrical shape paraffin, which holds a biological object inside the paraffin. And the paraffin is kept being solid by cooling while being handled. The image acquisition modulo captures the sectional image of the object merged into the paraffin consecutively. The second one is the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last one is the image processing and visualization module, which processes a series of acquired sectional images and generates a 3D volumetric model. To verify the condition for the uniform slicing, normal directional forces of the cutting edge according to the various cutting angles were measured using a strain gauge and the amount of the sliced chips were weighed and analyzed. Once the 3D model was constructed on the computer, user could manipulate it with various transformation methods such as translation, rotation, and scaling including arbitrary sectional view.

  • PDF

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

강박장애 환자에서의 안와전두피질 용적의 2년 추적 연구 (2 Year Follow-Up Study of Orbitofrontal Cortex Volume in Obsessive Compulsive Disorder)

  • 김성년;강도형;유소영;노규식;장준환;최정석;하태현;권준수
    • 대한불안의학회지
    • /
    • 제2권2호
    • /
    • pp.94-100
    • /
    • 2006
  • Objective : This study was designed to examine the volumetric abnormality of orbitofrontal cortex (OFC) and its change after 2 years of pharmacotherapy in obsessive compulsive disorder (OCD) patients. Method : Volumetric magnetic resonance imaging studies were conducted in 15 OCD patients and 13 normal volunteers. For 2 years, all patients took at least one serotonin reuptake inhibitor and atypical antipsychotics were used as an augmentation therapy in most patients. The follow-up MRI studies were conducted after the pharmacotherapy and OFC volumes were measured by the manual region of interest method. Results : Bilateral OFC volumes of 15 OCD patients were significantly greater than those of the normal volunteers before the treatment. After 2 years of the treatment, significant decrease was observed in bilateral OFC volumes of OCD patients to the extent that left OFC volume of OCD patients was not different from that of the normal volunteers. Conclusion : This finding suggests that OFC is directly related to the pathophysiology of obsessive compulsive disorder.

  • PDF

Radiosurgical Considerations in the Treatment of Large Cerebral Arteriovenous Malformations

  • Lee, Sung-Ho;Lim, Young-Jin;Choi, Seok-Keun;Kim, Tae-Sung;Rhee, Bong-Arm
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.378-384
    • /
    • 2009
  • Objective : In order to establish the role of Gamma Knife radiosurgery (GKS) in large intracranial arteriovenous malformations (AVMs), we analyzed clinical characteristics, radiological features, and radiosurgical outcomes. Methods : Between March 1992 and March 2005, 28 of 33 patients with large AVMs (> $10\;cm^3$ in nidus-volume) who were treated with GKS underwent single session radiosurgery (RS), and the other 5 patients underwent staged volumetric RS. Retrospectively collected data were available in 23 cases. We analyzed treatment outcomes in each subdivided groups and according to the AVM sizes. We compared the estimated volume, defined as primarily estimated nidus volume using MR images, with real target volume after excluding draining veins and feeding arteries embedded into the nidus. Results : Regarding those patients who underwent single session RS, 44.4% (8/18) had complete obliteration; regarding staged volumetric RS, the obliteration rate was 40% (2/5). The complete obliteration rate was 60% (6/10) in the smaller nidus group ($10-15\;cm^3$ size), and 25% (2/8) in the larger nidus group (over $15\;cm^3$ size). One case of cerebral edema and two cases (8.7%) of hemorrhage were seen during the latent period. The mean real target volume for 18 single sessions of RS was $17.1\;cm^3$ ($10.1-38.4\;cm^3$), in contrast with the mean estimated volume of $20.9\;cm^3$ ($12.0-45.0\;cm^3$). Conclusion : The radiosurgical treatment outcomes of large AVMs are generally poor. However, we presume that the recent development in planning software and imaging devices aid more accurate measurement of the nidus volume, therefore improving the treatment outcome.

PROTOTYPE AUTOMATIC SYSTEM FOR CONSTRUCTING 3D INTERIOR AND EXTERIOR IMAGE OF BIOLOGICAL OBJECTS

  • Park, T. H.;H. Hwang;Kim, C. S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.318-324
    • /
    • 2000
  • Ultrasonic and magnetic resonance imaging systems are used to visualize the interior states of biological objects. These nondestructive methods have many advantages but too much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct some biological objects to get the interior and exterior information, constructing 3D image from the series of the sliced sectional images gives more useful information with relatively low cost. In this paper, PC based automatic 3D model generator was developed. The system was composed of three modules. One is the object handling and image acquisition module, which feeds and slices objects sequentially and maintains the paraffin cool to be in solid state and captures the sectional image consecutively. The second is the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last is the image processing and visualization module, which processes a series of acquired sectional images and generates 3D graphic model. The handling module was composed of the gripper, which grasps and feeds the object and the cutting device, which cuts the object by moving cutting edge forward and backward. Sliced sectional images were acquired and saved in the form of bitmap file. The 3D model was generated to obtain the volumetric information using these 2D sectional image files after being segmented from the background paraffin. Once 3-D model was constructed on the computer, user could manipulate it with various transformation methods such as translation, rotation, scaling including arbitrary sectional view.

  • PDF

최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정 (Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor)

  • 임춘성;민경선
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Evaluation of Treatment Plan Quality between Magnetic Resonance-Guided Radiotherapy and Volumetric Modulated Arc Therapy for Prostate Cancer

  • Chang Heon Choi;Jin Ho Kim;Jaeman Son;Jong Min Park;Jung-in Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.121-128
    • /
    • 2022
  • Purpose: This study evaluated the quality of plans based on magnetic resonance-guided radiotherapy (MRgRT) tri-Co-60, linac, and conventional linac-based volumetric modulated arc therapy (linac-VMAT) for prostate cancer. Methods: Twenty patients suffering from prostate cancer with intermediate risk who were treated by MAT were selected. Additional treatment plans (primary and boost plans) were generated based on MRgRT-tri-Co-60 and MRgRT-linac. The planning target volume (PTV) of MRgRT-based plans was created by adding a 3 mm margin from the clinical target volume (CTV) due to high soft-tissue contrast and real-time motion imaging. On the other hand, the PTV of conventional linac was generated based on a 1 cm margin from CTV. The targets of primary and boost plans were prostate plus seminal vesicle and prostate only, respectively. All plans were normalized to cover 95% of the target volume by 100% of the prescribed dose. Dosimetric characteristics were evaluated for each of the primary, boost, and sum plans. Results: For target coverage and conformity, the three plans showed similar results. In the sum plans, the average value of V65Gy of the rectum of MRgRT-linac (2.62%±2.21%) was smaller than those of MRgRT tri-Co-60 (9.04%±3.01%) and linac-VMAT (9.73%±7.14%) (P<0.001). In the case of bladder, the average value of V65Gy of MRgRT-linac was also smaller. Conclusions: In terms of organs at risk sparing, MRgRT-linac shows the best value while maintaining comparable target coverage among the three plans.