• Title/Summary/Keyword: Volumetric Ratio

Search Result 383, Processing Time 0.024 seconds

Characterization of Thermal Properties for Glass Beads - Rubber Mixture (글라스 비즈 - 고무 분말 혼합물의 열전달 특성 연구)

  • Lee, Jung-Hwoon;Yun, Tae-Sup;Evans, T. Matthew
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.39-45
    • /
    • 2011
  • This study presents the thermal behaviors of glass beads-rubber mixtures depending on the volumetric fraction of each constituent and relative size between them. The transient plane source method is used to measure the effective thermal conductivity of mixtures. The discrete element method (DEM) and the thermal network model are integrated to investigate the particle-scale mechanism of heat transfer in granular packings. Results show that 1) the effective thermal conductivity decreases as the rubber fraction increases, and 2) the relative size between two solid particles dominates the spatial configuration of inter-particle contact condition that in tum determines the majority of heat propagation path through particle contacts. For the mixtures whose volumetric fraction of rubber is identical, the less conductive materials (e.g., rubber particles) with a large size facilitate heat transfer in granular materials. The experimental results and particle-scale observation highlight that the thermal conduction behavior is dominated not only by the volumetric fraction but also the spatial configuration of each constituent.

Basic Study on Monitoring System of Reservoir and Leeve Using Wireless Sensor Network (무선센서 네트워크 계측을 이용한 저수지 및 제방 계측시스템 구축에 관한 기초연구)

  • Yoo, Chanho;Kim, IkHoon;Lee, Seungjoo;Hwang, Jungsoon;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • Conventional monitoring method is used for evaluation of the reservoir and levee at the highest height sections. In recent years, automated measurement technology has been developed, and the measurement results are transmitted, collected and stored in real time into management office. Despite the development of real time monitoring technology, the measurement results are not used directly or indirectly with facility management at real time. Recently, as wireless sensor network measurement technology has been developed based on internet of things, this study proposed a real - time measurement and evaluation system based on wireless sensor network technology in the reservoir structure. As a result of the seepage analysis for the application, it was confirmed that the volumetric water content changes together with the change of the seepage line inside the embankment body according to the change of the water level of the embankment. In other words, the applicability of the measurement system with the volumetric water ratio set as the sensor node was verified.

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

Evaluation of regeneration after the application of 2 types of deproteinized bovine bone mineral to alveolar bone defects in adult dogs

  • Lee, Dajung;Lee, Yoonsub;Kim, Sungtae;Lee, Jung-Tae;Ahn, Jin-soo
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.370-382
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the preclinical results of 2 types of commercially available deproteinized bovine bone mineral (DBBM) when applied to alveolar bone defects in dogs. Methods: This study was conducted using 6 beagles. Alveolar defects in the mandible were formed and filled with 2 DBBMs produced by a similar procedure. Defects were randomly assigned to be filled using DBBM 1 or 2. All defects were covered with a collagen membrane and had a healing period of 12 weeks. After the dogs were sacrificed, histological, histomorphometric, and linear/volumetric analyses were performed. Results: Both DBBM groups showed similar histological findings, demonstrating that bone remodeling had occurred and new bone had formed. The residual bone particles were surrounded by newly formed vital bone. In the histomorphometric analysis, the ratio of the area of vital bone and residual bone substitute in DBBM 2 (38.18% and 3.47%, respectively) was higher than that of DBBM 1 (33.74% and 3.41%, respectively), although the difference was not statistically significant. There were also no statistically significant differences between both groups in linear and volumetric analyses using micro-computed tomography scans and digitized images of dental casts. Conclusions: In the present study, DBBM 1and 2, which were produced by similar processes, showed similar results in histological, histomorphometric, and volumetric analyses. Further studies are needed to identify more specific differences between the 2 DBBMs.

Development of Measurement Technology for Uptake and Diffusivity of Hydrogen gas in Rubber Materials using Volumetric Analysis (부피 분석법을 이용한 고무 소재의 수소 기체 장입량 및 확산도 측정 기술 개발)

  • LEE, JI HUN;JUNG, JAE KAP;BAEK, UN BONG;CHUNG, KI SOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.67-76
    • /
    • 2022
  • We developed a technology that can measure the hydrogen uptake and diffusivity of rubber materials by using the volumetric analysis method and diffusivity analysis program through the measurement of the water level in the graduated cylinder. In this method, hydrogen gas is charged at a certain pressure for a certain period of time for a rubber material exposed to a high-pressure hydrogen gas environment, and then the pressure is reduced to measure the change in the water level in the graduated cylinder in real time, and based on the measured value, it is a technology that can evaluate hydrogen uptake and diffusivity using diffusivity analysis program. Using this method, the hydrogen uptake and diffusivity of the NBR material were measured with respect to the change in the type and weight ratio of the filler used to improve the physical properties of the rubber material. In addition, uncertainty analysis was performed on the diffusivity measurement method.

Denitrification of Anaerobic Sludge in Hybrid type Anaerobic Reactor(I): Acetate as Substrate (Hybrid type 반응조에서의 혐기성 슬러지의 탈질(I): 초산을 기질로 사용한 경우)

  • Shin, Hang-Sik;Kim, Ku-Yong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.35-44
    • /
    • 1999
  • In this study, it was attempted to remove nitrate and carbon in a single-stage reactor using acetate as substrate. Hybrid type upflow sludge baffled filter reactor was adopted using anaerobic sludge. Sludge bed in the bottom of reactor was intended to remove carbon and nitrate by denitrification and methanogenesis. And floating media in the upper part of reactor were intended to remove remaining carbon which was not removed due to the inhibition of nitrogen oxide on methane producing bacteria. The reactor removed over 96% of COD and most of nitrate with volumetric loading rate of $4.0kgCOD/m^3{\cdot}day$, hydraulic retention time of 24hr, 4,000mgCOD/L, and $266mgNO_3-N/L$. Nitrate in anaerobic sludge was converted to nitrogen gas(denitrification) or ammonia (ammonification) according to pH of influent, COD removal efficiency was easily affected by the change of volumetric loading rates and nitrate concentration. And when influent pH was about 4.7, most nitrate changed to ammonia while when influent pH was about 6.8~7.0, most nitrate denitrified independent of $COD/NO_3-N$ ratio. Most granules were gray and a few were black. In gray-colored granule, black inner side was covered with gray substance and SEM illustrated Methanoccoci type microorganisms which were compact spherical shape. Anaerobic filter removed residual COD effectively which was left in sludge bed due to the inhibition of nitrogen oxide.

  • PDF

A Study About the Effect of Supercharging and Intake Charge on Engine Performance in Spark Ignition Gasoline Engine (SI 가솔린 엔진의 과급 및 흡기가 엔진 성능에 미치는 영향에 대한 연구)

  • Kim, Gi-Bok;Jin, Seok-Jun;Kim, Chi-Won;Yoon, Chang-Sik;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.2
    • /
    • pp.110-118
    • /
    • 2015
  • In this study, it is designed and used the test engine bed which is installed with turbocharger, and in addition to equipped using by oxygen adder. It has been controlled the oxygen volumetric fraction of intake air chrge, and supercharged flow rate into the cylinder of SI 4-stroke engine, and then, has been analyzed engine performance, combustion characteristics, and exhaust emission as analysis parameters. The tested parameters were the oxygen fraction and the variation of engine speed and air-fuel ratio.

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

Analysis of the Salt Separation and Concentration Using Counter-current Reverse Osmosis Spiral Wound Module (향류식 역삼투 나권형 모듈을 이용한 염분리농축 특성 해석)

  • 조한욱;민병렬;최광호
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.142-151
    • /
    • 1994
  • Counter-current type reverse osmosis spiral wound module was manufactured for the separation and concentration of salf solution. The ratio of permeate volumetric flow rate vs. brine volumetric flow rate was effective parameter between rejection and degree of cocentration. The reflection coefficient was correspondent to the relation between rejection and degree of cocentration by Spiegler-Kedem model. Counter-current reverse osmosis process had more osmotic pressure drop effect and more degree of concentration than general reverse osmosis process. As a result of computer calculation, the extension of module length than module diameter was more effective for the increase of degree of concentration.

  • PDF

A Study on the Optimization of Cylinder Head Port Flow for Hyundai H21/32 Medium-Speed Diesel Engines (현대 H21/32 중속 디젤엔진 실린더 헤드포트 최적화 연구)

  • Kim, Byung-Yoon;Kim, Jin-Won;Ghal, Sang-Hak
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.806-811
    • /
    • 2001
  • Since the characteristics of combustion and pollutant in Diesel engines were mainly effected by the characteristics of in-cylinder gas flow and fuel spray, an understanding of those was essential to the design of the D.I. Diesel engines. The improvement of volumetric efficiency of air charging into combustion chamber is a primary requirement to obtain better mean effective pressure of an engine. Since parameters such as the air resistances in intake and exhaust flow passages, valve lift and valve shape influence greatly to the volumetric efficiency, it is very important to investigate the flow characteristics of intake and exhaust port which develops air motion in the combustion chamber. In this study, two approach methods were used for design intake and exhaust port; experiment and computation which were made by using steady flow test rig and commercial CFD code. This paper presents the results of an experimental and analytical investigation of steady flow through the prototype cylinder head ports and valves of the HHI's H21/32 HIMSEN Engine.

  • PDF