• 제목/요약/키워드: Volumetric Error Map

검색결과 18건 처리시간 0.028초

정밀도 성능평가를 위한 3차원 측정기 수치모델 개발 (Development of Numerical CCM in Pursuit of Accuracy Assessment for Coordinate Measuring Machines)

  • 박희재
    • 대한기계학회논문집A
    • /
    • 제20권3호
    • /
    • pp.945-959
    • /
    • 1996
  • In this paper, a comprehensive computer model is described which can be used to generate the volumetric error map combining the machine parametric errors and the measurement prove error, for most types of CMMs and axis configurations currently in use.

기구볼바를 이용한 가공기계의 정밀도 평가 및 향상 기술 개발 (Accuracy Evaluation and Enhancement of Machine Tools Using a Kinematic Ball Bar)

  • 문준희;박희재;주종남
    • 한국정밀공학회지
    • /
    • 제13권6호
    • /
    • pp.114-121
    • /
    • 1996
  • This paper presents an useful technique for assessing the volumetric errors in multi-axis machine tools using the kinematic double ball bar. This system has been developed based on the volumetric error map which describes the 3 dimensional errors of machine tools. The developed system inputs the measured radial data of 3 different planes, respectively XY,YZ,ZX, analysing the volumetric errors such as positional. straightness, angle, and squareness errors, etc. The developed system has been tested in a practical machine tool, and showed high potential for the error assessment of multi-axis machine tools.

  • PDF

Machine Tools 공간오차 분석을 위한 Bal1-bar Artifact 연구 (A Study on the Ball-Bar Artifact for the Volumetric Error Calibration of Machine Tools)

  • 이응석;구상서;박달근
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.986-991
    • /
    • 2004
  • For volumetric error measurement and calibration for machine tools, manufacturing machine or coordinate measuring machine (CMM), are studied using a Ball-bar artifact. A design of the Ball-bar is suggested manufactured by Invar, which is a low thermal expansion material, and precision steel balls. The uncertainty for the artifact method is discussed. A method of the Ball-bar artifact for obtaining 3-D position errors in CMM is proposed. The method of error vector measurement is shown using the Ball-bar artifact. Finally, the volumetric error is calculated from the error vectors and it can be used for Pitch error compensation in conventional NC machine and 3-D position Error map for calibration of NC machine tools.

기계 체적오차가 고려된 가공형상-거칠기 측정 OMM 시스템 (The OMM system for machined form and surface roughness measurement concerned with volumetric error)

  • 이상준;김선호;김옥현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.681-686
    • /
    • 2000
  • Machining information such as machined form and surface roughness accuracy is an important factor for manufacturing precise parts. To this regard, OMM(On the Machine Measurement) has been issued for last several decades to alternate with CMM. In this research, measuring system consisting of a laser probe is developed for machined form and surface roughness measurement on the machine tool. The obtained machined form accuracy is compared with reference one defined in CAD model. The measured surface roughness data is compared with measured master surface beforehand. Furthermore, using the pre-defined volumetric error map approach compensates the geometric accuracy of the machine tool. The overall performance is compared with CMM, and verified the feasibility of the measurement system.

  • PDF

기계 체적오차가 고려된 가공형상-거칠기 측정 OMM 시스템 (The OMM System for Machined Form and Surface Roughness Measurement Concerned with Volumetric Error)

  • 이상준;김선호;김옥현
    • 한국정밀공학회지
    • /
    • 제17권7호
    • /
    • pp.232-240
    • /
    • 2000
  • Machining information such as machined form and surface roughness accuracy is an important factor for manufacturing precise parts. To this regard, OMM(On the Machine Measurement) has been issued for last several decades to alternate with CMM. In this research, measuring system consisting of a laser probe is developed for machined form and surface roughness measurement on the machine tool. The obtained machined form accuracy is compared with reference one defined in CAD model. The measured surface roughness data is compared with measured master surface beforehand. Furthermore, using the pre-defined volumetric error map approach compensates the geometric accuracy of the machine tool. The overall performance is compared with CMM, and verified the feasibility of the measurement system.

  • PDF

DEVELOPMENT OF COMPUTER SOFTWARE FOR CALCULATION OF VOLUMETRIC ERROR MAP IN 3 AXIS CMMs

  • Park, H.;M.Burdekin;G.Peggs
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1992년도 춘계학술대회 논문집 92
    • /
    • pp.131-158
    • /
    • 1992
  • Verification, calibration, and compensation are becoming more essential elements for manufacture and maintenance of high performance CMMs. A computer module of volumetric error generation has been developed to calculate volumetric errors (random as well as systematic) from measured parametric errors, accepting most types of CMMs in current use. New transformation rules have been derived to transform all the parametric errors with respect to the origin of working volume considered, then incorporated, then incorporated into the module of error calculation. Two cases of practical CMMs are tested with the developed module, and showed good performance.

  • PDF

3차원 측정 데이터를 이용한 자유곡면 가공물의 오차해석 (Error Analysis of Free-Form Artifact using 3D Measurement Data)

  • 김성돈;이성근;양승한;이재종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.439-442
    • /
    • 2001
  • The Accuracy of a free-form artifact is affected by machine tool errors, machining process errors, environmental causes and other uncertainty. This paper deals with methodological approach about machine tool errors that are defined the relationship between CMM and OMM inspections of the free-form artifact. In order to analyze the measurement data, Reverse engineering was used. In other words, Surface of Free-Form Artifact is generated by NURBS surface approximation method. Finally, Volumetric error map is made to compare surface of CMM data with that of OMM data.

  • PDF

Ball Bar를 이용한 칩마운터의 운동 오차 정밀도 측정 및 평가 기술 개발 (Development of measuring and calibrating technology for moving error and precision of chip mounter using Ball Bar)

  • 이창하;김정환;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.621-628
    • /
    • 2000
  • A kinematic ball bar measuring system can analyze the various errors of a machine tool easil rapidly with only one measurement, But it cannot be used to measure the errors of the equipment the semiconductor manufacturing (e.g. chip mounter, PCB router etc.) not to use a cir interpolation. This paper presents the method to apply a kinematic ball bar measuring system tc machines which use merely a linear interpolation Also, the work of measuring and calibratir various errors of a chip mounter with a kinematic bal1 bar measurement system is accomplished

  • PDF

Geometric Accuracy Measurement of Machined Surface Using the OMM (On the Machine Measurement) System

  • Kim, Sun-Ho;Lee, Seung-Woo;Kim, Dong-Hoon;Lee, An-Sung;Lim, Sun-Jong;Park, Kyoung-Taik
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권4호
    • /
    • pp.57-63
    • /
    • 2003
  • Machining information such as form accuracy and surface roughness is an important factor for manufacturing precise parts. To this regard, OMM (On the Machine Measurement) has been researched for last several decades to alternate CMM (Coordinate Measurement Machine) process. In this research, the OMM system with a laser displacement sensor was developed for measuring form accuracy and surface roughness of the machined workpiece on the machine tool. The surface roughness was estimated comparing the sensory signal with the reference data measured from master specimen. Also, form accuracy was determined from the moving averaged raw data. In addition, the geometric error map constructed beforehand using the geometric errors of the machine tool was used to compensate the obtained form accuracy. The overall performance was compared with CMM result, and verified the feasibility of the measurement system.