• 제목/요약/키워드: Volume-distribution

검색결과 2,622건 처리시간 0.027초

A new hyperbolic shear deformation plate theory for static analysis of FGM plate based on neutral surface position

  • Merazi, M.;Hadji, L.;Daouadji, T.H.;Tounsi, Abdelouahed;Adda Bedia, E.A.
    • Geomechanics and Engineering
    • /
    • 제8권3호
    • /
    • pp.305-321
    • /
    • 2015
  • In this paper, a new hyperbolic shear deformation plate theory based on neutral surface position is developed for the static analysis of functionally graded plates (FGPs). The theory accounts for hyperbolic distribution of the transverse shear strains and satisfies the zero traction boundary conditions on the surfaces of the beam without using shear correction factors. The neutral surface position for a functionally graded plate which its material properties vary in the thickness direction is determined. The mechanical properties of the plate are assumed to vary continuously in the thickness direction by a simple power-law distribution in terms of the volume fractions of the constituents. Based on the present new hyperbolic shear deformation plate theory and the neutral surface concept, the governing equations of equilibrium are derived from the principle of virtual displacements. Numerical illustrations concern flexural behavior of FG plates with Metal-Ceramic composition. Parametric studies are performed for varying ceramic volume fraction, volume fraction profiles, aspect ratios and length to thickness ratios. The accuracy of the present solutions is verified by comparing the obtained results with the existing solutions.

Analysis of buckling response of functionally graded sandwich plates using a refined shear deformation theory

  • Abdelhak, Z.;Hadji, L.;Khelifa, Z.;Hassaine Daouadji, T.;Adda Bedia, E.A.
    • Wind and Structures
    • /
    • 제22권3호
    • /
    • pp.291-305
    • /
    • 2016
  • In this paper, a refined shear deformation plate theory which eliminates the use of a shear correction factor was presented for FG sandwich plates composed of FG face sheets and an isotropic homogeneous core. The theory accounts for parabolic distribution of the transverse shear strains and satisfies the zero traction boundary conditions on the surfaces of the plate. The mechanical properties of the plate are assumed to vary continuously in the thickness direction by a simple power-law distribution in terms of the volume fractions of the constituents. Based on the present refined shear deformation plate theory, the governing equations of equilibrium are derived from the principle of virtual displacements. Numerical illustrations concern buckling behavior of FG sandwiches plates with Metal-Ceramic composition. Parametric studies are performed for varying ceramic volume fraction, volume fraction profiles, Boundary condition, and length to thickness ratios. The accuracy of the present solutions is verified by comparing the obtained results with the existing solutions.

아음속 횡단류에 수직 분사되는 분무의 액적크기 및 속도 분포 특성 (Droplet Sizes and Velocities from Single-Hole Nozzle in Transversing Subsonic Air-stream)

  • 이인철;조우진;이봉수;김종현;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.106-109
    • /
    • 2007
  • The spray plume characteristics of liquid water jet injected into subsonic cross-flow at 42 m/s were experimentally investigated. Nozzle has a 1.0 m diameter and L/D=5. Droplet sizes, velocities, volume flux were measured at each downstream area of the injector exit using phase Doppler particle anemometry. Measuring probe position is moved with 3-way transversing machine. Experimental results indicate that SMD is varied from 75 to $120{\mu}m$ distribution and it is uncertain layer structure. SMD peaks at the top of the spray plume. This phenomenon is related to the momentum exchange between column waves and cross-flow stream. Droplet vector velocities were varied from 11.5 to 33 m/s. A higher-velocity region can be identified in down edge region at Z/D : 40, 70 and 100. Lower-velocity region were observed on bottom position of the spray plume. Volume flux is a criterion to the droplet concentration. All volume flux distribution has a same structure that continuously decreases from the center region to the edge of the plume. Z/D : 20 is spatially less concentrated than in Z/D : 100.

  • PDF

항공화물 활성화를 위한 정책분석과 지방공항 발전방안 연구: 청주국제공항을 중심으로 (A Study on the Growth of Air Cargo Volume and the Development Plan for Regional Airport Focusing on Cheonng-Ju Int'l Airport)

  • 박원태;성연영;박성식
    • 한국항공운항학회지
    • /
    • 제32권2호
    • /
    • pp.112-123
    • /
    • 2024
  • Responding to rapid changes of global supply chain and fast increasing air cargo volume and demand for e-commerce market, this paper researched the development plans for regional airport specially focused on air cargo logostics through policy research. According to this research, political implications and development plans for Cheong Ju airport (CJJ) to become a part of global supply chain, a regional air cargo hub. Firstly, it is necessary to increase the length of the existing runway from 2,744m to 3,200m or to develop 3rd runway only for a civil aircraft use. Secondly, it is inevitable to develop new air cargo terminal to handle and export such high value-added products as semi-conductor or rechargeable battery through airport. In addition, facing re-shoring trends among global supply chain, CJJ can increase its air cargo volume and also provide feeder service to Incheon airport, inducing global distribution center near airport site.

중년비만 여성용 재킷패턴의 여유량 분포에 따른 착시효과 (The Visual Illusion Using the Adequate Ease Distribution of Jacket Pattern for the Middle Aged Women of Obese Figure)

  • 손부현
    • 한국생활과학회지
    • /
    • 제17권3호
    • /
    • pp.469-483
    • /
    • 2008
  • Body image is important as it is related to self-esteem and can be enhanced by clothing and the degree of enhancement is related to clothing fit. The purpose of the paper is to find the adequate ease distribution of jacket pattern for the obese women who want to slenderize their shape by optical illusion. Subjective evaluation of the visual appearance we collected and, at the same time, 3D clothing air volume was observed for the nine types of experimental jackets with different ease distribution. As results it was found that jacket pattern for the obese women is that the front width of pattern is wider than what of back width in waist and abdomen. It was also noted that there was distance between clothing and skin in the girth around hip of jacket. 3D scanner clearly demonstrated the distribution of ease is useful to find the pattern variables responsible for the slender appearance of the obese women. The ready-to-made clothes for the obese women's clothing should be manufactured systematically in due consideration of the diversity and scarcity of the obese women's body shape.

육계에서 경구투여시 enrofloxacin 제제에 따른 생체이용율 및 약물동태 (Bioavailability and Comparative Pharmacokinetics of Two Enrofloxacin Formulations in Broiler Chickens)

  • 윤효인;박승춘
    • 한국임상수의학회지
    • /
    • 제14권2호
    • /
    • pp.195-200
    • /
    • 1997
  • In order to compare the pharmacokinetic profiles of enrofloxacin-HCL)ENFLX-HCL) and enrofloxacin-KOH (ENFLX-KOH) after oral administration in broiler chickens, the study was performed. The chickens used in this study weighed $1.82 {\pm}0.2 kg$ and clinically healthy. The dose of intravenous and lral administration was 5 mg per kg of body weight as enrofloxacin. After intravenous injection of enrofloxacin, it showed two-compartment model with the rapid distribution phase and the slow elimination phase. The mean apparent volume of distribution (Vd) was 2.70 l/kg. The mean half-life of elimination and distribution showed 8.26 h and 0.44 h, respectively. The mean area under curve (AUC) was calculated as $19.7 {\mu} g{\cdot} h/ml$. After oral administration of ENFLX-HCL and ENFLX-KOH with a rate of dose 5 mg of enrofloxacin/kg of body weight, Both of the products were showed one-compartment model unlike that of i.v. enrofloxacin standard solution showed the mean bioavailability of 79.64% for the ENFLX-KOG and 86.24% for the ENFLX-HCL. The mean total body clearance of the former was 0.24 l/kg/h and the latter 0.42 l/kg/h. Both enorfloxacin formulations seemed to have good tissue distribution and penetration as indicated by large volume of distribution : 2.72 l/kg for the -KOH and 4.44 l/kg for the -HCL. With the results obtained in this study, ENFLX-HCL could be used in place of its salt form in chickens.

  • PDF

2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향 (The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution)

  • 김성준;이승준;박인규;이정은;박신형;설기호;김재철
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.41-47
    • /
    • 2013
  • 부피효과를 가지는 2차원 배열형 이온함으로부터 측정된 세기조절방사선치료의 선량분포와 부피효과를 가지지 않는 장치로부터 측정된 선량분포를 비교함으로써 이 효과가 측정결과에 미치는 영향에 대해 평가하였다. 조사면 크기에 따라 총 5개의 세기조절방사선치료계획을 5문 조사방식으로 가상의 팬톰에 시행하였다. 선량분포 측정은 매트릭스 팬톰, 빔 영상시스템, 필름 등 총 3가지 측정장치를 이용하였다. 측정된 값은 분석프로그램을 이용하여 전산화치료계획 시스템을 통해 획득된 선량분포와 비교하였다. 비교된 선량분포는 분석프로그램 상에서 상관계수와 감마값을 통해 측정장치의 부피효과 유무에 따른 차이를 분석한 결과 매트릭스 팬톰에서 최대 1.3% 이상으로 나타났다. 매트릭스 팬톰은 조사면의 크기가 작아질수록 내부의 이온함에 의해 부피효과가 커지게 되므로 다른 측정장치에 비해 더 큰 측정오차를 가지는 것으로 판단되었다.

한국재래(韓國在來) 염소의 체액량(體液量) (Body Fluid Volumes of Korean Native Goats)

  • 양일석;이영소;정순동
    • 대한수의학회지
    • /
    • 제16권2호
    • /
    • pp.187-190
    • /
    • 1976
  • In order to approximate plasma volume, extracellular fluid volume and total body water volume of Korean native goats, measurements were made of the volumes of distribution of Evans blue, potasium thiocyanate and antipyrine. The results obtained in this work were summarized as follows: 1. Plasma volume showed a range of 50 to 72ml/kg with a mean of $62{\pm}6.2ml/kg$ (SD). 2. Blood volume showed a range of 69 to 98ml/kg with a mean of $85{\pm}7.9ml/kg$. 3. Extracellular fluid volume showed a range of 265 to 310ml/kg with a mean of $297{\pm}18.3ml/kg$. 4. Interstitial fluid volume showed a range of 204 to 261ml/kg with a mean of $236{\pm}16.8ml/kg$. 5. Intracellular fluid volume showed a range of 380 to 436ml/kg with a mean of $420{\pm}12.6ml/kg$. 6. The volume of total body water showed a range of 680 to 735ml/kg with a mean of $714{\pm}17.7ml/kg$.

  • PDF

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

Optimization and Mathematical Modeling of the Transtubular Bioreactor for the Production of Monoclonal Antibodies from a Hybridoma Cell Line

  • Halberstadt, Craig R.;Palsson, Bernhanrd O.;Midgley, A.Rees;Curl, Rane L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권3호
    • /
    • pp.163-170
    • /
    • 2002
  • This report describes the use of a transtubular bioreactor to study the relative effects of diffusion versus perfusion of medium on antibody production by a hybridoma cell line. The study was performed with a high-density cell culture maintained in a serum-free, low-protein medium for 77 days. It was determined that the reactor possessed a macro-mixing pattern residence time distribution similar to a continuous stirred tank reactor (CSTR), However, due to the arrangement of the medium lines in the reactor, the flow patterns for nutrient distribution consist of largely independent medium path lengths ranging from short to long. When operated with cyclic, reversing, transtubular medium flow, some regions of the reactor (with short residence times) are more accessible to medium than others (with long residence times). From this standpoint, the reactor can be divided into three regions: a captive volume, which consists of medium primarily delivered via diffusion; a lapped volume, which provides nutrients through unilateral convection; and a swept volume, which operates through bilateral convection. The relative sizes of these three volumes were modified experimentally by changing the period over which the direction of medium flow was reversed from 15 min (larger captive volume) to 9 h (larger swept volume). The results suggest that antibody concentration increases as the size of the diffusion-limited (captive) volume is increased to a maximum at around 30 min with a sharp decrease thereafter. As reflected by changes in measured consumption of glucose and production of lactate, no significant difference in cellular metabolism occurred as the reactor was moved between these different states. These results indicate that the mode of operation of the transtubular bioreactor may influence antibody productivity under serum-free, low-protein conditions with minimal effects on cellular metabolism.