• Title/Summary/Keyword: Volume of distribution

Search Result 2,607, Processing Time 0.033 seconds

Distribution and Growth Characteristics of Acer pictum var. mono in Relation to Topography and Soil in Mt. Joongwang, Gangwon Province (강원도 중왕산 지역의 지형 및 토양요인에 따른 고로쇠나무의 분포와 생장 특성)

  • Um Tae-Won;Kim Gab-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.20 no.2
    • /
    • pp.200-207
    • /
    • 2006
  • The objective of this study was to investigate the site and growth characteristics of Acer pictum var. mono growing in the deciduous stands at Mt. Joongwang area located in Pyungchanggun, Kangwon-do. A. pictum var. mono was mainly distributed at the rather steep slope and aspect facing from northeast to northwest, and altitudes ranging from 1,000 to 1,200m. It grew at relatively deep a soil layer with high moisture and nutrients. Major competing species in the upper stories were Betula costata, Acer mandshuricum, Quercus mongolica, Cornus controversa, and herb plants such as Meehania urtidfolia, Isodon excisus, Astilbe chinensis var. davidii, Dryopteris crassirhizoma and Ainsliaea acerifolia in the floor. The height growth was 0.25m in early time, decreased gradually and sustained growth of lower than 10cm. The diameter growth of A. pictum was under 1mm in early time, but increased to 0.3mm/yr and showed continuous growth of 2mm/yr recently. Annual volume growth showed rapid increased about age 120 and then showed stable growth, so the rotation period of A. pictum is expected more than 200 years without decay of heartwood.

Network Structures of The Metropolitan Seoul Subway Systems (서울 대도시권 지하철망의 구조적 특성 분석)

  • Park, Jong-Soo;Lee, Keum-Sook
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.459-475
    • /
    • 2008
  • This study analyzes the network structure of the Metropolitan Seoul subway system by applying complex network analysis methods. For the purpose, we construct the Metropolitan Seoul subway system as a network graph, and then calculate various indices introduced in complex network analysis. Structural characteristics of Metropolitan Seoul subway network are discussed by these indices. In particular, this study determines the shortest paths between nodes based on the weighted distance (physical and time distance) as well as topological network distance, since urban travel movements are more sensitive for them. We introduce an accessibility measurement based on the shortest distance both in terms of physical distance and network distance, and then compare the spatial structure between two. Accessibility levels of the system have been getting up overall, and thus the accessibility gaps have been getting lessen between center located subway stops and remote ones during the last 10 years. Passenger traffic volumes are explored from real passenger transaction databases by utilizing data mining techniques, and mapped by GIS. Clear differences reveal between the spatial patterns of real passenger flows and accessibility. That is, passenger flows of the Metropolitan Seoul subway system are related with population distribution and land use around subway stops as well as the accessibility supported by the subway network.

  • PDF

Reconstruction of the Volcanic Lake in Hanon Volcano Using the Spatial Statistical Techniques (공간통계기법을 이용한 하논화산의 화구호 복원)

  • Choi Kwang-Hee;Yoon Kwang-Sung;Kim Jong-Wook
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.4 s.115
    • /
    • pp.391-403
    • /
    • 2006
  • The Hanon volcano located in the southern pan of Cheju Island, Korea has a wetland in its crater being used as a farmland. Previous researchers presumed this wetland was a maar lake in the past. Based on the seismic refraction method, the wetland sediment layer was estimated between 5 to 14 m deep, which is mostly in accordance with previous researches. However, this shows only the depths at some sites, not representing the whole spatial distribution. This study is an attempt to reconstruct the volcanic lake in Hanon crater by applying the spatial statistical techniques based on the depth information from the seismic survey and known data. The procedure of reconstruction is as follows: First, the depth information from the seismic survey and known data were collected and it was interpolated by IDW and Ordinary Kriging method. Next, with the interpolation map and the present DEM the paleo DEM was constructed. Finally, using the paleo lake level on core data, the boundary of volcanic lake was extracted from the paleo DEM. The reconstructed lake resembles a half-moon in the north of the central scoria cone. It is estimated that the lake was 5 m deep on average and 13 m deep at the deepest point. Although there are slight differences according to the interpolation techniques, it is calculated that the area of the lake was between 184,000 and $190000m^2,$ and its volume approximately $869,760m^3$. Because of the continuous deposition processes after the crater formation, the reconstructed volcanic lake would not indicate an actual lake at a specific time. Nevertheless, it offers a significant clue regarding the inner morphology and evolution of the crater.

Comparison of Esophageal Cancer Radiation Therapy Plans Using Volumetric Modulated Arc Therapy (체적 조절 호형 방사선치료(VMAT)를 활용한 식도암 치료계획 비교)

  • Won-Young Jeong;Jae-Bok Han;Young-Hyun Seo;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.249-256
    • /
    • 2024
  • The study aimed to evaluate the efficacy of treatment plans using full Arc and Partial Arc Coplanar volumetric modulated arc therapy and Non-Coplanar volumetric modulated arc therapy to minimize radiation treatment side effects, such as pneumonia, and protect normal organs in esophageal cancer radiotherapy. 30 patients who underwent Concurrent Chemoradiotherapy for esophageal cancer were included. Compared planning target volume, lung, heart, spinal cord and total monitor units among three treatment plans: fVMAT(2 Full Arc), pVMAT(4 Partial Arc), and ncVMAT(2 Partial Arc + 2 Non-Coplanar Arc). All plans met the PTV criteria, showing uniform distribution. The average dose to the heart was 5.8 Gy for fVMAT, 6.97 Gy for pVMAT, and 7.6 Gy for ncVMAT, with the lowest value in fVMAT, which was statistically significant. However, the average lung dose was 9.01 Gy for fVMAT, 7.71 Gy for pVMAT, and 7.12 Gy for ncVMAT, with V5Gy(%) values of 52.22%, 38.61%, 36.35% and V10Gy(%) values of 37.8%, 27.33%, 24.15% respectively. ncVMAT showed the lowest values, while fVMAT had the highest, with statistical significance. In conclusion, ncVMAT effectively reduces lung radiation exposure in esophageal cancer radiotherapy, potentially reducing the incidence of side effects such as pneumonia. However, considering factors like setup accuracy and treatment time, applying an appropriate treatment plan may lead to better outcomes.

Separation and Elution Behaviors of Some Metal-2-hydroxyarylazopyrazolone Chelates by Reversed Phase High Performance Liquid Chromatography (I) (역상 액체 크로마토그래피에 의한 금속-2-hydroxyarylazopyrazolone 유도체 킬레이트의 용리거동 및 동시분리에 관한 연구 (I))

  • Lee, Chang-Heon;Kang, Chang-Hee;Kim, Eun-Kyung;Lee, Won
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-114
    • /
    • 1994
  • The elution behaviors of Ni(II), Cu(II), Co(II), and Cr(II) in 1-phenyl-3-methyl-4(2-hydroxy-5-X-phenylazo)-5-pyrazolone, [Pm(2-OH)(5-X)PaPz](X=H, $CH_3$, $NO_2$, Cl) chelates have been studied by reversed phase HPLC. Thirteen metal-[Pm(2-OH)(5-X)PaPz] chelates were prepared and characterized by UV, IR, MS, and ICP spectroscopic methods. These metal-2-hydroxyarylazopyrazolone chelates were successfully separated on Novapak-$C_{18}$ column using methanol/water mixtures as a mobile phases. It was found that the chelates were eluted properly in an acceptable range of the capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of the capacity factor(log k') on the volume fraction of water in the binary mobile phase showed a good linearity. Also, there was a good linear dependence of the capacity factor on the liquid-liquid extraction distribution ratio($D_c$) in methanol-water/n-pentadecane extraction system by the batch method. It suggested that the retention of the chelates in the reverse phase liquid chromatographic system be largely due to the solvophobic effect.

  • PDF

Influence of Activation Temperature on Surface and Adsorption Properties of PAN-based Activated Carbon Fibers/Phenolic Resin Matrix Composites (활성화 온도에 의한 PAN계 활성탄소섬유/페놀수지 복합재료의 표면 및 흡착특성)

  • 박수진;김기동;이재락
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.97-104
    • /
    • 2000
  • PAN-based activated carbon fibers/phenolic resin matrix composites (ACFCs) were manufactured via molding process with oxidized carbon fabrics (plain-type) and phenolic resin (resole-type) compounded by 70 : 30 wt%. The green body (as molded) was submitted to carbonization (at 100$0^{\circ}C$) in an inert environment and activation (at 700, 800, 900 and 100$0^{\circ}C$) in a $CO_2$ environment. In this work, the influence of activation temperatures was investigated in surface properties, such as pH, acid- and base-values by titration method, and in adsorption properties, i.e., specific surface area and pore structures by BET-method of the composites. Also, the pressure drops of the specimens were calibrated by ASTM. As a result, the activation temperature influenced the surface property of ACFCs. When the activation temperature was higher than 90$0^{\circ}C$, the surface was gradually developed in basic nature. And, the evolutions of specific surface area, total pore volume and pore size distribution of ACFCs could be easily confirmed the dependence on the activation temperature. Among them, well-developed pore structure from adsorption characteristics was changed of the ACFCs activated at 90$0^{\circ}C$. Also, the pressure drop was slightly decreased with increasing the temperature due to increasing the burn-off with heat treatment temperature of ACFCs.

  • PDF

Building a Traffic Accident Frequency Prediction Model at Unsignalized Intersections in Urban Areas by Using Adaptive Neuro-Fuzzy Inference System (적응 뉴로-퍼지를 이용한 도시부 비신호교차로 교통사고예측모형 구축)

  • Kim, Kyung Whan;Kang, Jung Hyun;Kang, Jong Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.137-145
    • /
    • 2012
  • According to the National Police Agency, the total number of traffic accidents which occurred in 2010 was 226,878. Intersection accidents accounts for 44.8%, the largest portion of the entire traffic accidents. An research on the signalized intersection is constantly made, while an research on the unsignalized intersection is yet insufficient. This study selected traffic volume, road width, and sight distance as the input variables which affect unsignalized intersection accidents, and number of accidents as the output variable to build a model using ANFIS(Adaptive Neuro-Fuzzy Inference System). The forecast performance of this model is evaluated by comparing the actual measurement value with the forecasted value. The compatibility is evaluated by R2, the coefficient of determination, along with Mean Absolute Error (MAE) and Mean Square Error (MSE), the indicators which represent the degree of error and distribution. The result shows that the $R^2$ is 0.9817, while MAE and MSE are 0.4773 and 0.3037 respectively, which means that the explanatory power of the model is quite decent. This study is expected to provide the basic data for establishment of safety measure for unsignalized intersection and the improvement of traffic accidents.

Effect of Plastic Container Vent Ratio on Strawberry Quality during Precooling and Storage (플라스틱 컨테이너 상자의 개공율에 따른 딸기의 예냉 및 저장효과)

  • Lee, Ho-Joon;Seo, Jeong-Ah;Choi, Jeong-Hee;Lee, Kang-Dae;Jeong, Moon-Cheol
    • Food Science and Preservation
    • /
    • v.17 no.5
    • /
    • pp.581-585
    • /
    • 2010
  • The effects of plastic container vent ratio on fruit quality during strawberry precooling and storage were analyzed. Plastic containers ($520mm{\times}355mm{\times}182mm$) were manufactured with bottom and side vents at areal ratios of 5%, 10%, 15% and 20%. Fruit was loaded at a volume ratio of 80% prior to pressure cooling and storage at $5^{\circ}C$. The internal fruit temperature was $18^{\circ}C$ and the times taken to attain $2^{\circ}C$ after precooling were 1 hour 9 minutes, 1 hour 13 minutes, 2 hours 2 minutes, and 2 hours 51 minutes at vent ratios of 20%, 15%, 10%, and 5%, respectively. To mimic the current distribution system, precooled strawberries were packaged in tray wrapping and stored at $5^{\circ}C$. Changes in weight, bruising, extent of decay, and firmness, were measured. Weight loss, bruising, and decay were highest at a vent ratio of 20%, lowest at a vent ratio of 15%, and moderate at vent ratios of 5% and 10%. No significant among-treatment difference in fruit firmness was evident.

Analysis of all PCB Congeners in Air Samples by HRGC/HRMS (대기 시료 중 PCBs 전 이성체 분석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.309-319
    • /
    • 2003
  • This study was performed to describe analysis method of 209 PCB congeners in ambient air samples. The samples were collected by high volume air sampler in Chonju city. Extracted samples were cleaned by silicagel cleanup modified with sulfuric acid and activated carbon cleanup processing. The cleaned samples were analyzed by high resolution gas chromatography and high resolution mass spectrometry (HRGC/HRMS) with DB-5 column (60 m, 0.25 mm i.d., 0.25 m film thickness) to analyze the 209 kinds of PCB congeners. PCBs levels of air samples were detected to the range between 0.003 and $0.163pg-TEQ/m^3$. The PCBs congener of 162 kinds were detected in samples analysed using DB-5 column and 37 kinds peaks were overlapped with congeners more than one. It is difficult to isolate PCB 118/106 and PCB 105/127 in coplanar PCB, so it is likely to overestimate the concentration.. The distribution of coplanar-PCB congeners in origin source samples (Kanechlor and exhaust gas from incinerator) was compared with that in air samples, and PCB 81, PCB 77, PCB 126, and PCB 169 were higher in incinerator samples.

Preparation and Characterization of High Performance Activated Carbon Fibers from Stabilized PAN fibers (PAN계 안정화섬유로부터 고기능성 활성탄소섬유의 제조 및 특성)

  • 임연수;유기상;문숙영;정윤중;김명수;함현식
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.468-474
    • /
    • 2003
  • Activated carbon fibers were prepared from stabilized PAN fibers by physical and chemical activation to compare their characteristics. In this study, stabilized PAN fibers were activated by physical activation with steam and CO$_2$, and by chemical activation with KOH. The fabricated activated carbon fibers were evaluated and compared such as specific surface area, pore size distribution, pore volume, and amount of iodine adsorption. In the steam activation, a specific surface area of 1635 m$^2$/g was obtained after heat treatment at 990$^{\circ}C$. Otherwise, in the CO$_2$ activation, produced activated carbon fibers had been a specific surface area of 671 m$^2$/g after heat treatment at 990$^{\circ}C$. In chemical activation using KOH, a specific surface area of 3179 m$^2$/g was obtained with a KOH/ stabilized PAN fiber ratio of 1.5 : 1 at 900$^{\circ}C$. Nitrogen adsorption isotherms for fabricated activated carbon fibers showed type I and transformation from type I and II in the Brunauer-Deming-Deming-Teller (B.D.D.T) classification. Increasing specific surface area Increased the amount of iodine adsorption in both activation methods. Because the ionic radius of iodine was smaller than the interior micropore size of activated carbon fibers.