• Title/Summary/Keyword: Volume median diameter.

Search Result 35, Processing Time 0.16 seconds

Assessing Abdominal Aortic Aneurysm Progression by Using Perivascular Adipose Tissue Attenuation on Computed Tomography Angiography

  • Shuai Zhang;Hui Gu;Na Chang;Sha Li;Tianqi Xu;Menghan Liu;Ximing Wang
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.974-982
    • /
    • 2023
  • Objective: Recent studies have highlighted the active and potential role of perivascular adipose tissue (PVAT) in atherosclerosis and aneurysm progression, respectively. This study explored the link between PVAT attenuation and abdominal aortic aneurysm (AAA) progression using computed tomography angiography (CTA). Materials and Methods: This multicenter retrospective study analyzed patients with AAA who underwent CTA at baseline and follow-up between March 2015 and July 2022. The following parameters were obtained: maximum diameter and total volume of the AAA, presence or absence of intraluminal thrombus (ILT), maximum diameter and volume of the ILT, and PVAT attenuation of the aortic aneurysm at baseline CTA. PVAT attenuation was divided into high (> -73.4 Hounsfield units [HU]) and low (≤ -73.4 HU). Patients who had or did not have AAA progression during the follow-up, defined as an increase in the aneurysm volume > 10 mL from baseline, were identified. Kaplan-Meier and multivariable Cox regression analyses were used to investigate the association between PVAT attenuation and AAA progression. Results: Our study included 167 participants (148 males; median age: 70.0 years; interquartile range: 63.0-76.0 years), of which 145 (86.8%) were diagnosed with AAA accompanied by ILT. Over a median period of 11.3 months (range: 6.0-85.0 months), AAA progression was observed in 67 patients (40.1%). Multivariable Cox regression analysis indicated that high baseline PVAT attenuation (adjusted hazard ratio [aHR] = 2.23; 95% confidence interval [CI], 1.16-4.32; P = 0.017) was independently associated with AAA progression. This association was demonstrated within the patients of AAA with ILT subcohort, where a high baseline PVAT attenuation (aHR = 2.23; 95% CI, 1.08-4.60; P = 0.030) was consistently independently associated with AAA progression. Conclusion: Elevated PVAT attenuation is independently associated with AAA progression, including patients of AAA with ILT, suggesting the potential of PVAT attenuation as a predictive imaging marker for AAA expansion.

Uniformity Analysis of Unmanned Aerial Application with Variable Rate Spray System (무인항공 변량방제 시스템의 살포 균일도 분석)

  • Koo, Young Mo;Bae, Yeonghwan
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.111-125
    • /
    • 2018
  • In this study, we evaluated the uniformity of deposition rate and particle size distributions of the variable rate application technique using the unmanned rotorcraft by measuring the spray pattern according to path location in the range of spraying flight. The coefficient of variation (CV) of the lateral coverage rate for the overlapped distribution with the spray swath of 3.6 m in both guidance and auto-pilot flight modes maintaining constant flight speed was about 30% and the CV of the coverage rate by the flight path location was extremely small. Therefore, it was assessed that the variable rate application technology compensating for the variation of ground speed was superior in terms of spray uniformity. In addition, the droplet size distributions in both volume median diameter(VMD) and number median diameter(NMD) were adequate for aerial application and uniform in terms of lateral distribution. Thereafter, we intend to contribute to a precise application on small-scaled fields using the unmanned agricultural rotorcraft by the variable rate application.

Measuring the characteristic of aerial spray by rotary wing (회전익 항공기 공중살포 특성 측정)

  • Lim, Se-Hoon;Song, Byung-Heum
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2009
  • This paper presents results from field studies carried out to monitor off-target droplet movement of endosulfan insecticide applied to the Korea chestnut tree area. As a results, mean airborne drift values were recorded 25m as average from downwind of a single flight line(sample line) in mountain terrain and mean effective swath width was recorded 19.5m as average in a plain. In terms of characteristics of geography of Korea aerial application is mainly carried out in mountain terrain. The equipment, weather conditions, and appropriate aerial spray technic are required for effective aerial application. In particular, the pilot can get effective results when he only sprays with consideration of environment factors since there is much turbulence in mountain terrain. Eventually, the most effective factor of droplets drift is to estimate the local weather conditions exactly.

  • PDF

Physicochemical Characteristics of Particulate Matter Emitted from Aluminum Casting Process (알루미늄 주조과정에서 배출되는 입자상물질의 물리·화학적 특성)

  • Jeong-Min Suh;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.33 no.5
    • /
    • pp.297-304
    • /
    • 2024
  • PM (Particulate Matters) was collected from a bag filter dust collector at an aluminum foundries, and its physicochemical properties were investigated using particle size analyzer and scanning electron microscopy with energy dispersive X-ray spectrometer (SEM/EDS). The median volume diameter of the particles passing through the pretreatment dust collector of the cyclone was approximately 10 ㎛. The cyclone pretreatment dust collector was shown to significantly reduce the throughput of large particles with a particle size of 100 ㎛ or more. The chemical composition of the particles showed a high Al content, and trace amounts of Mg, Si, and Zn were detected.

A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Analysis of Arterial Stiffness Variation by Photoplethysmographic DC Component (광용적맥파 비맥동성분에 의한 혈관경직도 변화 분석)

  • Lee, Chung-Keun;Shin, Hang-Sik;Kong, In-Deok;Lee, Myoun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Assuming that photons absorbed by a vessel do not have acute variations, DC component reflect the basal blood volume (or diameter) before blood pulsation. Vascular stiffness and reflection is influenced by changes in basal blood volume (or diameter). This paper describes analysis of the characteristic variations of vascular stiffness, according to relative variations in DC components of the PPG signal (25-75%). For quantitative analysis, we have used parameters that were proposed previously, reflection and stiffness index, and the second derivative of PPG waveform, b/a and d/a. Significantly, the vascular stiffness and reflections were increased according to increase in DC component of the PPG signal for more than about 3% of baseline values. The systolic blood pressure were increased from $113.1{\times}13.18$ to $116.2{\times}13.319$ mmHg, about 2.76% (r = 0.991, P < 0.001) and the AC component of the PPG signal were decreased from $2.073{\times}2.287$ to $1.973{\times}2.2038$ arbitrary unit, about 5.09% (r = -0.993, P < 0.001). It is separated by DC median and correlation analysis was performed for analyzing vascular characteristics according to instantaneous DC variations. There are significant differences between two correlation coefficients in separated data.

Characteristics of Black Carbon Particles in Ambient Air Using a Single Particle Soot Photometer (SP2) in May 2013, Jeju, Korea (SP2 (Single Particle Soot Photometer)를 이용한 제주도 5월 Black Carbon 특성)

  • Oh, Jun;Park, Jinsoo;Lee, Sanguk;Ahn, Joonyoung;Choi, Jinsoo;Lee, Sangdeok;Lee, Yonghwan;Kim, Hyunjae;Hong, Youdeog;Hong, Jihyung;Kim, Jeongho;Kim, SangWoo;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.3
    • /
    • pp.255-268
    • /
    • 2015
  • Single particle soot photometer (SP2) is an advanced instrument capable of real-time measurement of concentration, coating thickness, and size distribution of individual BC particle using laser-induced incandescence. So far, there have been insufficient studies examining the real-time characteristics of BC in Korea. In this study, we examined temporal variations in BC concentration and mass size distribution of BC in volume equivalence diameter at a background site of Aewol, Jeju in May. Average concentration and mass median diameter (MMD) of BC particles measured during the study period (06~ 16 May 2013) were $0.69{\pm}0.48{\mu}g/m^3$ and $196{\pm}17nm$, respectively. The BC concentration measured in Aewol was very similar to that observed in the spring of 2012 in Baengnyeong island, and showed diurnal profiles similar to those in other background areas. MMD of BC ranged from 172 to 222 nm. It was found that the mass size distribution of BC varied depending on the location (ground-based), season, types of air masses, and altitude (aircraft-based).

A Study on the Positioning of Ice Sensors for Assessing Airworthiness of Military Helicopter (군용헬기 결빙 감항인증 시험을 위한 결빙센서 위치선정에 관한 연구)

  • Kim, Chan Dong;Hur, Jang Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.495-501
    • /
    • 2016
  • The measurement of icing conditions needs to be carried out accurately by the ice detector system of an aircraft. Ice detector systems should be installed in locations not affected by backwash, rotor downwash or moving doors or other equipment. Various analyses were carried out in order to find the proper locations sufficiently far from these interfering effects. In this study, the optimum position of the ice detector was assessed using computer simulation, with respect to different flight modes, flow velocities and the amount and distribution of liquid water around the sensor.

Effect of Gamma Knife Surgery for Uveal Melanoma (Uveal Melanoma에 대한 Gamma Knife Radiosurgery의 효과)

  • Kim, Gi-Hong;Cho, Jung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 1997
  • The optimal management of uveal melanoma is still a matter of controversy. To determine the effect of Gamma Knife surgery for patients with uveal malanoma. the authors reviewed the results of 5 patients underwent Gamma Knife sugery between Sep. 1993 and Dec. 1996. The mean age was 60.7 years ranging from 42.5 to 76.5 years. Median follow-up was 13.29 months and the patient with follow up period more than 6 months was 4. The mean tumor volume was $3442 mm^3$(mean diameter 15.3 mm) and all patients were irradiated with a mean maximum dose of 74Gy(range $60\~80\;Gy$), using the $50\%$ isodose. After Gamma Knife surgery. one pateint showed complete disapperance in tumor size with follow-up 32 months, one enucleation due to progression, and 2 no interval change. In regard to vision, one patient blind. one enucleation, and 2 patients had no interval change. According to our experiences, Gamma Knife surgery for uveal melanoma be able to achieve local tumor control, spare the eyeball, and have possibility of save vision.

  • PDF

In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost

  • Lee, Jason Joon Bock;Choi, Jinhyun;Ahn, Sung Gwe;Jeong, Joon;Lee, Ik Jae;Park, Kwangwoo;Kim, Kangpyo;Kim, Jun Won
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.121-128
    • /
    • 2017
  • Purpose: To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. Materials and Methods: Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A total of 55 patients with a minimum follow-up of 1 month after WBI were evaluated. Optically stimulated luminescence dosimeter (OSLD) detected radiation dose delivered to the skin during IORT. Acute toxicity was recorded according to the Common Terminology Criteria for Adverse Events v4.0. Clinical parameters were correlated with seroma formation and maximum skin dose. Results: Median follow-up after IORT was 25.9 weeks (range, 12.7 to 50.3 weeks). Prior to WBI, only one patient developed acute toxicity. Following WBI, 30 patients experienced grade 1 skin toxicity and three patients had grade 2 skin toxicity. Skin dose during IORT exceeded 5 Gy in two patients: with grade 2 complications around the surgical scar in one patient who received 8.42 Gy. Breast volume on preoperative images (p = 0.001), ratio of applicator diameter and breast volume (p = 0.002), and distance between skin and tumor (p = 0.003) showed significant correlations with maximum skin dose. Conclusions: IORT as a boost was well-tolerated among Korean women without severe acute complication. In vivo dosimetry with OSLD can help ensure safe delivery of IORT as a boost.