• 제목/요약/키워드: Volume flux

검색결과 476건 처리시간 0.03초

A study on temporal accuracy of OpenFOAM

  • Lee, Sang Bong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권4호
    • /
    • pp.429-438
    • /
    • 2017
  • Cranke-Nicolson scheme in native OpenFOAM source libraries was not able to provide 2nd order temporal accuracy of velocity and pressure since the volume flux of convective nonlinear terms was 1st accurate in time. In the present study the simplest way of getting the volume flux with 2nd order accuracy was proposed by using old fluxes. A possible numerical instability originated from an explicit estimation of volume fluxes could be handled by introducing a weighting factor which was determined by observing the ratio of the finally corrected volume flux to the intermediate volume flux at the previous step. The new calculation of volume fluxes was able to provide temporally accurate velocity and pressure with 2nd order. The improvement of temporal accuracy was validated by performing numerical simulations of 2D Taylor-Green vortex of which an exact solution was known and 2D vortex shedding from a circular cylinder.

연소실 초기온도 변화에 따른 순간열유속에 관한 연구 (A Study of Hear Flux and Instantaneous Temperature According to the Initial Tamperature of Combustion Chamber in a Constant Volume Combustion Chamber)

  • 이치우
    • 한국산업융합학회 논문집
    • /
    • 제6권3호
    • /
    • pp.193-200
    • /
    • 2003
  • In the production of internal combustion engines, there has been a move towards the development of high performance engines with improved fuel efficiency, lighter weight and smaller sizes. These trends help to answer problems in engines related to thermal load and abnormal combustion. In order to investigate these problems, a thin film-type probe for instantaneously measuring temperatures has been suggested. A method for manufacturing such a probe was established in this study. The instantaneous surface temperature of a constant volume combustion chamber was measured by this probe and the heat flux was obtained through Fourier analysis. In order to thoroughly understand the characteristics of combustion, the authors measured the wall temperature of the combustion chamber and computed heat flux through a cylinder wall while varying the protrusion height of the probe. For achieving the above goals, a instantaneous temperature probe was developed, thereby making possible the analysis of the instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

  • PDF

Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리 (Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.177-184
    • /
    • 1989
  • 항생물질 발효액의 균사체 분리에 있어서 Modified regenerated cellulose 막을 이용한 Cross-flow filtration으로 높은 Flux를 얻을 수 있었다. 막분리시 가급적 높은 유속, 높은 온도, 특정 균사체농도(약 20% PMV)에서 높은 Flux를 보여주었으며 Fouling 정도는 균사체 농도가 높을수록 또한 유속이 낮을수록 심각한 것으로 나타났다. 발효액을 농축 분리할 때의 Flux profile은 1단계 Sublayer형성에 의한 급속감소, 2단계 평형, 3단계 Fouling에 의한 급속감소의 세 구간으로 나눌 수 있었으며 Diafiltration의 적용으로 3단계의 Flux 감소 현상을 현저히 완화시킬 수 있었다. 한편 Diafiltration에 의한 항생물질 회수시 초기부터Diafiltration하는 것보다는 특정 PMV까지 농축시킨 후 Diafiltration하는 경우에 작업시간과 여액의 Volume을 최소화 할 수 있었으며 본 실험에서는 98%의 회수율을 얻기 위해서 Di-afiltration을 시작하는 Optimum PMV는 20%였다.

  • PDF

연손실 순간온도 측저에 있어서 돌출높이에 따른 실험적 연구 (Study on the Heat Flux Using Instantaneous Temperature as Height of Probe in the Combustion Chamber)

  • 이치우;김지훈;김시범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.395-402
    • /
    • 2001
  • The gasoline engine tends to high performance, fuel economy, small-sized. Therefore, it is necessary to solve the problems on thermal load, abnormal combustion, etc, in the engine, Thine film instantaneous temperature measurement probe was made. And the manufactural method of probe was established. The instantaneous surface temperatures in the constant volume combustion chamber were measured by this probe and the heat flux was obtained by Fourier analysis. The authors measured the wall temperature of combustion chamber and computed the heat flux through the cylinder wall in order to understand the combustion characteristics depending on height of probe. For achieving this goal, the thin film instantaneous temperature probe was developed for analyzing the instantaneous surface wall temperature and unsteady heat flux on the constant volume combustion chamber.

  • PDF

비정렬 셀 중심 방법에서 확산플럭스의 새로운 수치근사방법 (A NEW NUMERICAL APPROXIMATION OF DIFFUSION FLUX IN UNSTRUCTURED CELL-CENTERED METHOD)

  • 명현국
    • 한국전산유체공학회지
    • /
    • 제11권1호
    • /
    • pp.8-15
    • /
    • 2006
  • The existing approximations of diffusion flux in unstructured cell-centered finite volume methods are examined in detail with each other and clarified to have indefinite expressions in several respects. A new numerical approximation of diffusion flux at cell face center is then proposed, which is second-order accurate even on irregular grids and may be easily implemented in CFD code using cell-centered finite volume method with unstructured grids composed of arbitrary convex polyhedral shape.

돌출높이와 초기온도 변화에 따른 연소실 벽면에서의 열유속에 관한 연구 (A Study of Heat Flux According to the Initial Temperature of Combustion Chamber and Blight of Probe in a Constant Volume Combustion Chamber)

  • 이치우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1055-1062
    • /
    • 2004
  • As for the Production of internal combustion engines there has been further movement toward development of high Performance engines with improved fuel efficiency as well as a lightweight and a small size. These tendencies help to solve the problems in engines for example, such as thermal load. abnormal combustion and so on. In order to investigate these Problems, a thin film-type probe for measuring instantaneous temperature has been suggested. A method for manufacturing such a probe was established in this study The instantaneous surface temperature of a constant volume combustion chamber was measured by using this probe and the heat flux was obtained through Fourier analysis In order to thoroughly understand the characteristics of combustion. authors measured wall temperature of combustion chamber and calculated heat flux through a cylinder wall while varying the protrusion height of probe. For these Purposes, the instantaneous surface temperature probe was developed. thereby making possible the analysis of instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

고온 열전달면의 각도에 따른 분무냉각 특성에 관한 연구 (A Study on the Spray Cooling Characteristics according to the Angle of Hot Heat Transfer Surface)

  • 윤두호;오철;윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.320-327
    • /
    • 2002
  • An experimental study of heat transfer from hot flat surface to water sprays was conducted in high temperature region. Heat transfer measurements for hot flat surface were made by 4 sheathed C-A thermocouples. Droplets volume flux were also measured-independently at a position in spray field. The test conditions included variations in droplets volume flux, subcooling of cooling water of $1.565\times10^{-3} to 14.089\times10^{-3}m^3/m^2s and 80 to $20^{\circ}C$ respectively. The effects of inclination angle on heat transfer were investigated and changes in inclination angle of hot flat surface affected heat transfer coefficients of high temperature region.

평판 분무냉각 시의 고온역 열전달계수에 관한 연구 (A Study on the High Temperature Region Heat Transfer Coefficients for the Spray Cooling of Hot Flat Plates)

  • 윤두호;오철;윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.25-32
    • /
    • 2000
  • In this paper, experiments investigating the high-temperature region heat transfer coefficients for the spray cooling of hot flat plates were performed by down spray water using flat spray nozzles. The heat transfer surface is made of copper and is 100mm in length and 40mm in width and 15mm in thickness. The experimental condition of spray are as follows: temperatures of the water droplets are T=20~$80^{\circ}C$ and droplets volume fluxes are D=0.001565~0.010438$m^3/m^2s$. Next, correlating equations for the heat transfer characteristics of spray cooling in the high temperature region are developed from the effects of droplets volume flux and the surface temperature of heat transfer plate.

  • PDF

축 자속 영구자석 발전기의 체적에 따른 성능 비교 (Performance Comparison of Axial Flux Permanent Magnet Generator according to Volume)

  • 장석명;구민모;박유섭;최장영;이용복;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1071-1072
    • /
    • 2011
  • The axial flux machine has higher power density than conventional radial flux machine, so it is widely applied to various industrial area, for instance, low speed wind power generator. For the conventional radial flux machine, 2D finite element method (FEM) is generally applied, but axial flux machine has to employ 3D FEM with long analysis time due to its own structural characteristic. This paper deals with the performance comparison of axial flux machine according to volume.

  • PDF

횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성 (Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number)

  • 김종현;이봉수;구자예
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.