• 제목/요약/키워드: Volume determination

검색결과 531건 처리시간 0.037초

Improvement and Verification of the Wear Volume Calculation

  • 김형규;이용호
    • KSTLE International Journal
    • /
    • 제6권1호
    • /
    • pp.21-27
    • /
    • 2005
  • A technique for a wear volume calculation is improved and verified in this research. The wear profile data measured by a surface roughness tester is used. The present technique uses a data flattening, the FFT and the windowing procedure, which is used for a general signal processing. The measured value of an average roughness of an unworn surfnce is used for the baseline of the integration for the volume calculation. The improvements from the previous technique are the procedures of the data flattening and the determination of a baseline. It is found that the flattening procedure efnciently manipulates the raw data when the levels of it are not horizontal, which enables us to calculate the volume reasonably well and readily. By comparing it with the weight loss method by using artificial dents, the present method reveals more volume by aroung 3~10%. It is attributed to the protruded region of the specimen and the inaccuracy and data averaging during the weght loss measurement. From a thorough investigation, it is concluded that the present technique can provide an accurate wear volume.

DTM 보간기법별 토공량 산정과 지형분석에 관한 연구 (A Study on the Earthwork Volume Computation and Topographic Analysis using DTM Interpolations)

  • 박운용;김천영;이현우
    • 대한공간정보학회지
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 2001
  • 지형의 특성을 공간상에 수치적으로 표현하는 수치지형모형(DTM)은 전산기의 발달과 더불어 최근 건설 분야의 계획 단계에서 광범위하게 적용이 되고 있으며, 특히 도로설계와 도시계획에 있어서 DTM을 이용한 토공량과 정지표고 및 면적 산정은 대표적인 적용 분야들이다. 따라서, 본 연구에서는 DTM을 이용한 토공량 계산에 정확도에 관련된 요소를 고려하여 최적 토공량 산정을 연구하는데 있어서, 부산광역시 15개 구를 연구 대상지역으로 선정하여 국립지리원 발행 1:5,000 지형도를 수치화하였다. 또한, 토공량과 높이별 정지면적 및 정지표고를 결정하여 향후 절 성토 등으로 인하여 발생 가능한 지형의 변화를 추정할 수 있는 정지표고 산정 모형을 제시하였으며, 그리고 토공량 계산시 사용되는 보간 기법별 토공량의 차이를 분석하였다. 분석결과 역거리보간법이 면적과 표면적 그리고 토공량에서 가장 큰 값을 보였고, 최근린기법이 가장 적을 값이 분포를 나타내었다. 최종적으로 본 연구에서 산정된 토공량은 부산광역시에서 추정한 값들과 매우 근사한 값을 보였다.

  • PDF

LiDAR 데이터를 이용한 토공량 산정 (The Determination of Earthwork Volume using LiDAR Data)

  • 강준묵;윤희천;민관식;위광재
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.533-540
    • /
    • 2006
  • In recent years, civil-engineering work is desired the terrain information to be more efficient in earthwork volume calculation. One method for collecting elevation data is LiDAR. Lidar data was used to produce rapidly an accurate digital elevation model of the terrain, compared with the conventional ground surveys, photogrammetty, and remote sensing. Raw Lidar data is combined with GPS positional data to georeference the data sets. Lidar data is edited and processed to generate surface models, elevation models, and contours. Here we can either create a Tin Volume Surface or a Gird Volume Surface. Triangulated Irregular Network(TIN) has complex data structure, but it can describe well terrain surface features. As we have seen, we search the efficiency for earthwork volume calculation using Lidar data. One conclusion we can draw from this study is that Lidar data is more accurate result than digital map in the calculation of earthwork volume.

  • PDF

파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

부피법을 이용한 고압·극저온 수소 흡착량 측정 방식의 기본 원리 (Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols)

  • 오현철
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.349-356
    • /
    • 2016
  • Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as 'volume correction using a non-porous material', showing a reliable cold volume correction.

Phase Identification of Nano-Phase Materials using Convergent Beam Electron Diffraction (CBED) Technique

  • Kim, Gyeung-Ho;Ahn, Jae-Pyoung
    • Applied Microscopy
    • /
    • 제36권spc1호
    • /
    • pp.47-56
    • /
    • 2006
  • Improvements are made to existing primitive cell volume measurement method to provide a real-time analysis capability for the phase analysis of nanocrystalline materials. Simplification is introduced in the primitive cell volume calculation leading to fast and reliable method for nano-phase identification and is applied to the phase analysis of Mo-Si-N nanocoating layer. In addition, comparison is made between real-time and film measurements for their accuracy of calculated primitive cell volume values and factors governing the accuracy of the method are determined. About 5% accuracy in primitive cell determination is obtained from camera length calibration and this technique is used to investigate the cell volume variation in WC-TiC core-shell microstructure. In addition to chemical compositional variation in core-shell type structure, primitive cell volume variation reveals additional information on lattice coherency strain across the interface.

메조다공성 유기-실리카를 이용한 구리(II)의 예비농축과 불꽃원자 흡수분광법으로의 정량 (Preconcentration of Copper(II) Using Mesoporous Organo-Silicas and Determination by Flame Atomic Absorption Spectrometry)

  • Moghimi, Ali
    • 대한화학회지
    • /
    • 제52권2호
    • /
    • pp.155-163
    • /
    • 2008
  • 유기-실리카 이용한 잔유 구리(II)의 양을 빠른 추출을 위한 간단하고 재현성을 가지는 방법과 불꽃원자 흡수분광법으로의 검출에 대해 연구하였다. 공통으로 존재하는 이온은 분리와 검출에 간섭받지 않았다. 예비농축인자는 100 ml시료 용량에 대해 100 (1 ml 추출용량) 이 였다.제안된 방법의 검출한계는 1.0 ng ml-1이다. 최적조건하에서 흡착제의 최고흡수용량은 5 mg 구리/g 흡착제 였다. 최적조건하에서 상대표준편차는 2.8% (n=10)을 얻었다. 다양한 양의 구리(II)이온은 스파이크한 자연수와 합성수를 시험 시료로 하여 정확도 등을 시험하였다.

황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정 (Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco)

  • 백순옥;장기철;이운철;한상빈
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

A Preliminary Study on the Determination of Road Maintenance for Each Region Using Multiple Regression Analysis

  • Kim, Kinam;Lee, Minjae
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.618-619
    • /
    • 2015
  • The costs due to the maintenance and its method of national road have increased every year, and the maintenance costs have become higher due to the maintenance method without considering the characteristics of each region. This study is a preliminary study regarding the determination of maintenance method according to the characteristics of each region by applying variables (e.g. serviced time, traffic volume, average temperature, maximum temperature, minimum temperature, rainfall, and snowfall) to decide the maintenance and its method through the correlation analysis of road maintenance and repair period for each regional agency using the maintenance history data of national road management agency.

  • PDF

Sorption of Thiocyanate Silver Complexes and Determination of Silver by Diffuse Reflectance Spectroscopy

  • Kononova, O.N.;Goryaeva, N.G.;Vorontsova, T.V.;Bulavskaya, T.A.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1832-1838
    • /
    • 2006
  • The present paper is focused on sorption concentration of silver (I) on some complex-forming ion exchangers in the initial thiocyanate form and subsequent determination of Ag(I) in the phase of anion exchanger AN-25 by diffuse reflectance spectroscopy. The sorption and kinetic characteristics of the sorbents were investigated. The apparent stability constants of thiocyanate silver complexes in the ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Ag(I) determination in aqueous solutions. The calibration curve is linear in the concentration range of 10-200 mg/L (sample volume is 10.0 mL) and the detection limit is 2 $\mu$g/mL. The presence of $Na^+,\;K^+,\;Mg^{2+}$ (macrocomponents) as well as of Ni (II), Co (II), Cu (II) do not hinder the determination of silver (I).