• Title/Summary/Keyword: Volume Reduction

Search Result 1,771, Processing Time 0.041 seconds

A Study of Energy Dependency in Intensity Modulated Radiation Therapy of Lung Cancer (폐암환자의 세기조절방사선치료에서 에너지에 따른 선량분포 특성 비교)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.191-199
    • /
    • 2008
  • PTV considered for the energy, dose distribution exposed to lung and spinal cord, and the characteristic of DVH(Dose Volume Histogram) were compared and investigated by planning the intensity modulated radiation therapy (IMRT) using the photon energies of 6 MV and 10 MV according to tumor location like as the anterior, middle, and posterior regions of lung, and the mediastinum region in lung cancer patients. Our institution installed the linear accelerator (Varian 21 EX-s, USA) equipped with 120 multileaf collimator for lung cancer patients, which is producing the photon energies of 6 MV and 10 MV, and radiation therapy planning was performed with ECLIPSE system (Varian, SomaVision 6.5, USA), which support inverse treatment planning. The tomographic images of 3 mm slice thickness for lung cancer patients were acquired using planning CT, and acquired tomographic images were sent to the Varis system, and then treatment planning was performed in the ECLIPSE system. The radiation treatment planning of the IMRT was processed from various angles according to the regions of the tumor, and using various beam lines according to the size and location of the tumor. The investigation of the characteristic of dose distributions for the energy of 6 MV and 10 MV according to tumor locations in lung cancer patients resulted that the maximum dose of 10 MV energy was 1.2% less than that of 6 MV energy without depending on the tumor location of lung cancer, and the reduction effects of MU were occurred from 10 to 25 MU. Radiation dose exposed to the lung satisfied the less 30% of V20, however radiation dose in 6 MV energy was from 0.1% to 0.5% less than that in 10 MV energy. Radiation dose exposed to the spinal cord for 6 MV energy was from 0.6% to 2.1% less than that for 6 MV energy.

  • PDF

Cardiovascular Effects of Free Movement of Abdominal Muscle in Prone Positioning during General Anesthesia (전신마취동안에 복와위시 자유로운 복근 움직임이 심혈관계에 미치는 영향)

  • Kim, Ji-Yoon;Lee, Dong-Won;Seo, Il-Sook;Kim, Sae-Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.206-215
    • /
    • 2007
  • Background : The prone position is often used for operations involving the spine and provides excellent surgical access. The complications associated with the prone position include ocular and auricular injuries, and musculoskeletal injuries. In particular, the prone position during general anesthesia causes hemodynamic changes. To evaluate the cardiovascular effects of the prone position in surgical patients during general anesthesia, we investigated the effects on hemodynamic change of the prone position with the Jackson spinal surgery table. Materials and Methods : Thirty patients undergoing spine surgery in the prone position were randomly selected. After induction of general anesthesia, intra-arterial and central venous pressures (CVP) were monitored and cardiac output was measured by $NICO^{(R)}$. We measured stroke volume, cardiac index, cardiac output, mean arterial pressure, heart rate, CVP and systemic vascular resistance (SVR) before changing the position. The same measurements were performed after changing to the prone position with the patient on the Jackson spinal surgery table. Results : In the prone position, there was a significant reduction in stroke volume, cardiac index and cardiac output. The heart rate, mean arterial pressure and CVP were also decreased in the prone position but not significantly. However, the SVR was increased significantly. Conclusion : The degree of a reduced cardiac index was less on the Jackson spinal surgery table than other conditions of the prone position. The reduced epidural pressure caused by free abdominal movement may decrease intraoperative blood loss. Therefore, the Jackson spinal surgery table provides a convenient and stable method for maintaining patients in the prone position during spinal surgery.

  • PDF

The Analysis of Predictive Factors for the Identification of Patients Who Could Benefit from Respiratory-Gated Radiotherapy in Non-Small Cell Lung Cancer (비소세포성 폐암에서 호흡동기방사선치료 적용 환자군의 선택을 위한 예측인자들의 분석)

  • Jang, Seong-Soon;Park, Ji-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.228-239
    • /
    • 2009
  • Purpose: 4DCT scans performed for radiotherapy were retrospectively analyzed to assess the possible benefits of respiratory gating in non-small cell lung cancer (NSCLC) and established the predictive factors for identifying patients who could benefit from this approach. Materials and Methods: Three treatment planning was performed for 15 patients with stage I~III NSCLC using different planning target volumes (PTVs) as follows: 1) PTVroutine, derived from the addition of conventional uniform margins to gross tumor volume (GTV) of a single bin, 2) PTVall phases (patient-specific PTV), derived from the composite GTV of all 6 bins of the 4DCT, and 3) PTVgating, derived from the composite GTV of 3 consecutive bins at end-exhalation. Results: The reductions in PTV were 43.2% and 9.5%, respectively, for the PTVall phases vs. PTVroutine and PTVgating vs. PTVall phases. Compared to PTVroutine, the use of PTVall phases and PTVgating reduced the mean lung dose (MLD) by 18.1% and 21.6%, and $V_{20}$ by 18.2% and 22.0%, respectively. Significant correlations were seen between certain predictive factors selected from the tumor mobility and volume analysis, such as the 3D mobility vector, the reduction in 3D mobility and PTV with gating, and the ratio of GTV overlap between 2 extreme bins and additional reductions in both MLD and $V_{20}$ with gating. Conclusion: The additional benefits with gating compared to the use of patient-specific PTV were modest; however, there were distinct correlations and differences according to the predictive factors. Therefore, these predictive factors might be useful for identifying patients who could benefit from respiratory-gated radiotherapy.

Incidence and Prognostic Factors of Radiation Pneumonitis in NSCLC Treated with Intensity Modulated Radiation Therapy(IMRT) (세기조절방사선치료(IMRT)로 치료한 비소세포폐암 환자에서의 방사선 폐렴)

  • Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.35-44
    • /
    • 2008
  • Purpose: To evaluate the incidence and prognostic factors of treatment-related pneumonitis in non-small-cell lung cancer(NSCLC) patients treated with intensity modulated radiation therapy(IMRT). Materials and Methods: One-hundred-five patients with NSCLC treated with IMRT between 1 August 2004 and 30 November 2006 were analyzed retrospectively. The mean age of patients was 62.9 years, and squamous carcinomas were confirmed in 81 patients(77%). Sixty-six patients(62.9%) were classified as stage III, and 59 patients had lesions in the right lung. Twenty-seven patients were treated with a dose of 3,060 cGy preoperatively, and 10 patients were given a dose of 5,040 cGy postoperatively. Sixty-eight patients received a dose of 7,020 cGy for curative intent. Sixty-eight patients were treated with the use of the CORVUS planning system and 37 patients were treated with the use of the ECLIPSE planning system. Results: Of 105 patients, 21 patients(20%) had abnormal radiological findings, but only seven patients(6.7%) required treatment for radiation pneumonitis. Six of the seven patients had other serious lesions, including a bronchioesophageal fistula(one patient), recurrence in the treatment field(two patients), brain metastasis(one patient) and lung-to-lung metastasis(two patients); all of these patients died within 19 months after radiation treatment. Sixteen patients(23.5%) that received planning with the CORVUS system had abnormal lung findings. Five patients(13.5%) had abnormal lung findings with the use of the ECLIPSE planning system. Other prognostic factors such as perioperative radiation therapy, a volume over 10% of the V20 volume in the right lung, were also statistically significant. Conclusion: This retrospective analysis suggests that IMRT could be a beneficial treatment modality for the reduction of radiation pneumonitis in NSCLC patients. However, the higher incidence of abnormal radiological findings in perioperative patients treated with relatively lower doses($3,060{\sim}5,040$ cGy) suggest the need for judicious treatment planning in preoperative or postoperative treatment.

Clinical Parameters Predicting Responsiveness to Treatment in Enuresis Patients (야뇨증 치료반응 예측에 관계하는 평가지표)

  • Lee, Kang-Gyoon;Lee, Hyun-Jung;Lim, Yun-Ju;Kwon, Duck-Geun;Kim, Eun-Jin;Pai, Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.272-279
    • /
    • 2007
  • Purpose : We tried to find out the clinical parameters which predict the outcome of treatment in children with enuresis. Methods : Enuresis patients who visited our hospital during 2003-2007 were included. Parameters such as age, gender, height, weight, minimal voided volume, maximal voided volume, maximum functional bladder capacity, frequency of voiding, urine S,G. before and after sleep were measured and an enuresis diary was also recorded. The reduction in wetting frequencies were classified into three groups; none(<50%), partial(50-90%) and complete(90%) response groups. We also compared the 'initial responders' who showed improvement(${\ge}50%$) during the 2 weeks of evaluation and behavioral therapy to the 'initial non-responders'. Results : Parameters mentioned above showed no significant relation to the treatment out-come. The response rate during the 2 weeks of the evaluation period was 32%(49/151) [complete in 1.3% (2/151), partial in 29.6% (47/151)]. Two-months' treatment responses were complete in 14(40%), partial in 19(54.3%) and none in 2(5.9%) responders(n=35), while they were 10(13.5%), 46(62.2%) and 18(24.3%), respectively in the non-responders(n=73) (P<0.05). Conclusion : We suggest that initial 'responsiveness' can be used as a predictor for good treatment outcome in patients with enuresis.

  • PDF

The Relation between Collateral Circulation and $^{99m}Tc$-MIBI Heart SPECT (심근경색에서 측부순환 유무에 따른 $^{99m}Tc$-MIBI 심근 SPECT 소견)

  • Kim, Jae-Man;Na, Deug-Young;Park, Eun-Kyung;Yang, Hyung-In;Kim, Deog-Yoon;Kang, Heung-Sun;Choue, Chung-Whee;Kim, Kwon-Sam;Kim, Myung-Shick;Song, Jung-Sang;Bae, Jong-Hoa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 1994
  • The coronary collateral vessels have revealed their significance in terms of reduction of infarct size, preservation left ventricular function, and prevention of left ventricular aneurysm in patients with myocardial infarction. The purpose of this study were to evaluated the relation between collateral circulation and $^{99m}Tc$-MIBI Heart SPECT in patient with acute myocardial infarction and their clinical significance. The fifty six MI patients with antegrade TIMI perfusion grade 0 and 1 were studied. The patients were classified into two groups; Group I inclueded 30 patients with grade 2, 3 Collateral flow. Group II inclueded 26 patients with grade 0, 1 Collateral flow. Collateral filling were graded from 0 to 3: 0- none, 1- Filling of side branch only, 2- Partial filling of the epicardial segment, 3- Complete filling of epicardial segment. Clinical variables, left ventricular function, $^{99m}Tc$-MIBI Heart SPECT were analyzed with angiographic finding. Results were following: 1) Collateral visualization was found to be greater in patient with involvement of right coronary artery (RCA). The collateral development site of infarct related artery was RCA 15 cases, left anterior descending artery (LAD) 10 cases, left circumflex artery (LCX) 5 cases, and the collateral circulation from LAD to RCA was 13 cases (40.6%). 2) There was a tendency to be decreased in peak CK activity with group I. 3) The presence of good collateral channels was more frequently $^{99m}Tc$-MIBI reversible perfusion defect (83.4% vs 15.3%, p<0.05). 4) No differences of left ventricular end diastolic volume (LVEDV), left ventricular end systolic volume (LVESV), ejection fraction (EF) were noted between group I and group II. The presence of good collateral channels did affect the frequency of occurrence of $^{99m}Tc$-MIBI reversible perfusion defect.

  • PDF

Lung Volumes and Diffusing Capacity in Bronchiectasis: Correlation with the Findings of High Resolutional CT (기관지확장증의 흉부고해상전산화단층촬영소견과 폐기량 및 폐확산능과의 관계)

  • Kim, Yeon-Jae;Park, Jae-Yong;Won, Jun-Hee;Kim, Chang-Ho;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.489-499
    • /
    • 1999
  • Background: The patient with bronchiectasis may have obstructive ventilatory impairment combined with mild restrictive ventilatory impairment due to fibrosis of surrounding lung parenchyme and pleural adhesions caused by chronic recurrent pulmonary infections. Since hyperinflation or emphysematous change can be occured in bronchiectasis, pulmonary functions such as lung volumes and diffusing capacity may also vary with associated emphysema. Methods: For the evaluation of lung volumes and diffusing capacity in bronchiectasis with respect to the anatomic types and severity of bronchiectasis, a total of 40 cases comprising 24 cases of tubular, and 16 cystic type of bronchiectasis were analyzed retrospectively. Correlation between lung functions and extent of bronchiectasis or associated emphysema detected in HRCT were also evaluated. Results: Vital capacity(VC) tended to decrease in cystic type than in tubular type. As the severity of bronchiectasis became serious, the VC were significantly reduced, whereas the total lung capacity(TLC), residual volume(RV) and its ratio to the total lung capacity(RV/TLC) had no significant difference. Lung clearance index(LCI) was significantly increased in cystic type than in tubular type, whereas the slope of phase III in single breath nitrogen curve($\triangle$N2/L) was not significantly changed regard to the type and severity of bronchiectasis. DLCO and DLCO/VA reflecting diffusing capacity were significantly decreased in cystic type and also as the severity of bronchiectasis became serious. The correlation coefficient of VC, DLCO and LCI with the extent of bronchiectasis were -0.322, -0.339 and 0.487, respectively, whereas other parameters were not significantly correlated with the extent of bronchiectasis. VC and DLCO correlated negatively with the extent of emphysema while RV, RV/TLC, LCI and $\triangle$N2/L correlated positively. Conclusion: These findings suggest that the reduction of VC and diffusing capacity or uneven distribution of inspired gas in bronchiectasis are related to both the extent of bronchiectasis and associated emphysema while increased residual volume be related to the extent of associated emphysema alone.

  • PDF

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

A Review on the Recycling of the Concrete Waste Generate from the Decommissioning of Nuclear Power Plants (원전 해체 콘크리트 폐기물의 재활용에 대한 고찰)

  • Jeon, Ji-Hun;Lee, Woo-Chun;Lee, Sang-Woo;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.285-297
    • /
    • 2021
  • Globally, nuclear-decommissioning facilities have been increased in number, and thereby hundreds of thousands of wastes, such as concrete, soil, and metal, have been generated. For this reason, there have been numerous efforts and researches on the development of technology for volume reduction and recycling of solid radioactive wastes, and this study reviewed and examined thoroughly such previous studies. The waste concrete powder is rehydrated by other processes such as grinding and sintering, and the processes rendered aluminate (C3A), C4AF, C3S, and ��-C2S, which are the significant compounds controlling the hydration reaction of concrete and the compressive strength of the solidified matrix. The review of the previous studies confirmed that waste concretes could be used as recycling cement, but there remain problems with the decreasing strength of solidified matrix due to mingling with aggregates. There have been further efforts to improve the performance of recycling concrete via mixing with reactive agents using industrial by-products, such as blast furnace slag and fly ash. As a result, the compressive strength of the solidified matrix was proved to be enhanced. On the contrary, there have been few kinds of researches on manufacturing recycled concretes using soil wastes. Illite and zeolite in soil waste show the high adsorption capacity on radioactive nuclides, and they can be recycled as solidification agents. If the soil wastes are recycled as much as possible, the volume of wastes generated from the decommissioning of nuclear power plants (NPPs) is not only significantly reduced, but collateral benefits also are received because radioactive wastes are safely disposed of by solidification agents made from such soil wastes. Thus, it is required to study the production of non-sintered cement using clay minerals in soil wastes. This paper reviewed related domestic and foreign researches to consider the sustainable recycling of concrete waste from NPPs as recycling cement and utilizing clay minerals in soil waste to produce unsintered cement.