• 제목/요약/키워드: Volume Pulse

검색결과 303건 처리시간 0.028초

연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성 (The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain)

  • 박재윤;고용술;이재동;송원섭;박상현;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구 (A study for its Characteristics with Electric Variation in an Electrical Discharge Machining)

  • 신근하
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 춘계학술대회 논문집
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

전기방전소결에 의해 제조된 다공성 및 다공성 표면을 갖는 Ti-6Al-4V 임플란트 : (1) 제조방법 및 기본적 특성 (Fully Porous and Porous Surfaced Ti-6Al-4V Implants Fabricated by Electro-Discharge-Sintering: (1) Fabrication Method and Fundamental Characteristics)

  • 현창용;허재근;이원희
    • 한국분말재료학회지
    • /
    • 제12권5호
    • /
    • pp.325-331
    • /
    • 2005
  • Implant prototypes with various porosities were fabricated by electro-discharge-sintering of atomized spherical Ti-6Al-4V powders. Single pulse of 0.75 to 2.0 kJ/0.7 g-powder, using 150, 300, and $450{\mu}F$ capacitors was applied to produce a fully porous and porous surfaced implant compact. The solid core formed in the center of the compact after discharge was composed of acicular ${\alpha}+{\beta}$ grains and porous layer consisted of particles connected in three dimensions by necks. The solid core and neck sizes increased with an increase in input energy and capacitance. On the other hand, pore volume decreased with increased capacitance and input energy due to the formation of solid core. Capacitance and input energy are the only controllable discharge parameters even though the heat generated during a discharge is the unique parameter that determines the porosity of compact. It is known that electro-discharge-sintering of spherical Ti-6Al-4V powders can efficiently produce fully-porous and porous surfaced Ti-6Al-4V implants with various porosities in a short time less then 400 isec by manipulating the discharging condition such as input energy and capacitance including powder size.

연료레일 압력과 엔진 속도가 가스연료 시스템에 미치는 영향에 관한 연구 (A Study on the Effects of Fuel Rail Pressure and Engine Speed on Gas Fuel System)

  • 곽윤기
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.579-585
    • /
    • 2018
  • 이번 연구는 가스 연료의 연료 공급 시스템에서 분사 압력과 엔진 속도에 따른 연료 분사 특성을 확인하였다. 이번 실험에서 연료 레일 압력은 1.5에서 6.0 bar까지 1.5 bar 단위로 증가시키고, 엔진 속도는 1,000 에서 6,000 RPM으로 1000 RPM 간격으로 설정하였다. 실제 엔진 작동을 고려하여 분사 펄스폭은 각각 2.5 ms, 5.0 ms 및 13.0 ms로 설정하였으며, 이는 각각 엔진 주행상태에서 저, 중 및 고 부하 운전조건에 해당한다. 결론적으로 100cc 연료레일의 경우, 분사 압력 4.5bar에서 가장 우수한 성능을 보였고, 1000 ~ 6000RPM의 엔진 속도에서 엔진 출력을 보장하는 최소 요구 분사량 53 cc을 얻을 수 있다.

Relationship between Thoracic Kyphosis and Selected Cardiopulmonary Parameters and Respiratory Symptoms of Patients with Chronic Obstructive Pulmonary Disease and Asthma

  • Aweto, Happiness Anulika;Adodo, Rachel Ilojegbe
    • The Journal of Korean Physical Therapy
    • /
    • 제33권4호
    • /
    • pp.179-186
    • /
    • 2021
  • Background: Patients with advanced asthma and chronic obstructive pulmonary disease (COPD) have postural deviations such as thoracic hyperkyphosis, forward shoulder posture (FSP) due to an increase in head and cervical protraction, reduced shoulder range of motion and a corresponding increase in scapula elevation and upward rotation. Unlike congenital vertebral kyphosis that are permanent and rigid deformities with bony and other structural deformations which cause respiratory impairment, these deformities in these patients may be more flexible. Since the thoracic hyperkyphosis has been implicated as having adverse health consequences it is necessary to evaluated the relationship between thoracic kyphosis and cardiopulmonary functions of patients with COPD and asthma. Methods: It was a cross-sectional analytical study. Eighty-four eligible patients with COPD and asthma were recruited from the Respiratory Unit, Department of Medicine, Lagos University Teaching Hospital (LUTH), and basic anthropometric parameters, pulmonary parameters, cardiovascular parameters, thoracic kyphosis (Cobb) angle and presence of respiratory symptoms of participants were assessed. Data was analyzed using SPSS version 20. Results: There was no significant correlation between the thoracic kyphosis and selected pulmonary parameters (Forced Expiratory Volume in one second (FEV1, p=0.36), Forced Vital Capacity (FVC, p=0.95), Peak Expiratory Flow Rate (PEFR, p=0.16), Thoracic expansion (TE, p=0.27)/cardiovascular parameters (Systolic Blood Pressure (SBP, p=0.108), Diastolic Blood Pressure (DBP, p=0.17) and Pulse Rate (PR, p=0.93) as well as the respiratory symptoms (SGRQ scores, p=0.11) in all subjects. Conclusion: There was no relationship between thoracic kyphosis and selected pulmonary/cardiovascular parameters as well as respiratory symptoms in patients with COPD and asthma.

근적외선 형광 영상시스템의 PWM 제어에 관한 연구 (A Study on PWM Control of Near-Infrared Fluorescence Imaging System)

  • 이병호;반성범
    • 한국정보기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.115-121
    • /
    • 2018
  • 근적외선을 이용한 형광 영상은 방사능에 대한 걱정이 없고 수술 중 실시간으로 영상 확인이 가능한 장점이 있다. 따라서 감시림프절 생검에 형광 영상을 이용하는 실험이 활발히 진행되고 있다. 형광 영상장비는 LED, 카메라와 같은 고발열 부품이 사용되어 안정적인 발열 억제 수단으로 수랭 방식의 쿨링 시스템을 사용하고 있다. 형광 영상장비에서 수랭 쿨링 시스템은 큰 부피를 차지하여 장비의 소형화 측면에서는 단점이 된다. 장비의 소형화를 위해 공랭 쿨링 방식을 이용할 경우 발열이 문제가 된다. 본 논문에서는 장비의 소형화를 위해 PWM 제어를 이용한 공랭 방식을 적용하여 실험을 했고, 장비를 장시간 사용해도 문제가 없는 일정한 품질의 형광 영상과 발열 억제 성능을 확인했다.

Influence of palm oil fuel ash on behaviour of green high-performance fine-grained cement mortar

  • Sagr, Salem Giuma Ibrahim;Johari, M.A. Megat;Mijarsh, M.J.A.
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.121-146
    • /
    • 2022
  • In the recent years, the use of agricultural waste in green cement mortar and concrete production has attracted considerable attention because of potential saving in the large areas of landfills and potential enhancement on the performance of mortar. In this research, microparticles of palm oil fuel ash (POFA) obtained from a multistage thermal and mechanical treatment processes of raw POFA originating from palm oil mill was utilized as a pozzolanic material to produce high-performance cement mortar (HPCM). POFA was used as a partial replacement material to ordinary Portland cement (OPC) at replacement levels of 0, 5, 10, 15, 20, 25, 30, 35, 40% by volume. Sand with particle size smaller than 300 ㎛ was used to enhance the performance of the HPCM. The HPCM mixes were tested for workability, compressive strength, ultrasonic pulse velocity (UPV), porosity and absorption. The results portray that the incorporation of micro POFA in HPCMs led to a slight reduction in the compressive strength. At 40% replacement level, the compressive strength was 87.4 MPa at 28 days which is suitable for many high strength applications. Although adding POFA to the cement mixtures harmed the absorption and porosity, those properties were very low at 3.4% and 11.5% respectively at a 40% POFA replacement ratio and after 28 days of curing. The HPCM mixtures containing POFA exhibited greater increase in strength and UPV as well as greater reduction in absorption and porosity than the control OPC mortar from 7 to 28 days of curing age, as a result of the pozzolanic reaction of POFA. Micro POFA with finely graded sand resulted in a dense and high strength cement mortar due to the pozzolanic reaction and increased packing effect. Therefore, it is demonstrated that the POFA could be used with high replacement ratios as a pozzolanic material to produce HPCM.

무창돈사를 위한 컨트롤러 일체형 환기팬 개발 (Development of Exhaust Fan with an Embedded Controller for Windowless Swine Housing)

  • 김웅
    • 농업생명과학연구
    • /
    • 제50권2호
    • /
    • pp.187-194
    • /
    • 2016
  • 본 연구는 무창돈사에서 최적 환경조절이 가능한 시스템을 구축하고자 환경조절이 가능한 모형돈사를 제작하여 온도분포특성을 분석하고 ICT 융합기술을 활용한 온도센서 위치 최적화 및 컨트롤 일체형 환기팬을 개발하고자 하였다. 팬 상부에 부착된 센서에 의해 측정된 온도는 다른 측점온도보다 1℃ 내의 낮은 온도차를 나타내어 측정오차를 고려할 때 온도센서가 팬 상부에 위치하여도 문제가 없을 것으로 판단되었다. 환기팬 성능은 최대 출력일 때 회전수 1920rpm, 송풍량 125㎥/min로 나타났으며, 최대 효율은 개방면적비 약 70%를 고려할 경우 사용된 환기팬의 적정 송풍량은 75㎥/min에 60pa로 나타났다. 댐퍼의 개방면적비가 약 70%일 때 환기팬의 동력과 상관없이 최대효율을 나타내었다. 팬의 출력별 회전수는 출력 100%일 때 최대 1,920rpm으로 나타났으며, 컨트롤러의 펄스 듀티비를 변화시킴에 따라 AC 출력 위상이 지연 없이 변화하는 것으로 나타나 빠른 응답속도로 팬 속도조절이 가능한 것으로 판단되었다.

Attention-Based Heart Rate Estimation using MobilenetV3

  • Yeo-Chan Yoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권12호
    • /
    • pp.1-7
    • /
    • 2023
  • 딥러닝의 발전은 의료 분야에서도 다양한 응용을 가능하게 하고 있으며 이러한 애플리케이션 중에 심박수 측정은 개인의 건강을 관리하기 위한 필수적인 아이템이라 할 수 있다. 광혈류 측정을 이용한 기존 방법의 경우 스마트워치 같은 장비의 착용이 필수적이다. 그러나 최근 딥러닝 기술의 발전은 비침습식으로 원격에서 사용자의 얼굴 이미지를 분석하여 심박수를 높은 성능으로 측정가능하게 한다. 본 연구에서는 모바일 환경에서 사용 가능한 경량화된 심박수 추정 방법론을 제안한다. 이 방법론은 2D 컨볼루션에 기반한 특화된 2채널 네트워크 구조를 사용하여, 혈류와 근육 수축으로 인한 얼굴의 미세한 움직임과 색상 변화를 고려한다. 제안하는 네트워크 구조는 이미지 특성을 분석하는 인코더와 혈류량 파동을 예측하는 회귀 레이어로 구성되어있다. 이러한 복합적인 특성을 동시에 분석함으로써, 제한된 컴퓨팅 리소스를 가진 환경에서도 심박수를 정확하게 추정할 수 있다. 이 연구의 접근 방식은 침습적인 기술 없이도 심박수를 효과적으로 모니터링 할 수 있는 새로운 경로를 제공할 것으로 예상한다.

HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계 (The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters)

  • 최은경;최영희;김도형;김용호;윤세영;박재석;김건열;이계영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권4호
    • /
    • pp.415-425
    • /
    • 2001
  • 배 경 : 폐기종의 중증도 판정에 있어서 병리학적 기준은 기강(air space)의 확장 정도에 있으며, 이는 고해상도 전산화 촬영 (high resolution computed tomography, HRCT)에 의해 결정되는 폐기종 점수(emphysema scoring)와 좋은 상관성을 보인다는 것은 주지의 사실이다. 한편 폐기종의 주증상은 운동성 호흡곤란이므로 폐기종에 대한 임상적 평가는 운동능력의 감소를 측정하는 것이 타당하다고 알려져 있다. 그러나 대개의 경우 폐기종의 중증도 판정은 안정시 폐기능 검사에 의존하는 경우가 흔하며, 병리학적 중증도 판정과 상관성이 높다고 알려져 있는 고해상도 전산화 촬영에 의한 폐기종 점수와 운동부하 폐기능검사 지표들과의 상관성 여부에 대한 연구는 드문 실정이다. 이에 본 연구에서는 폐기종의 중증도 판정에 있어서 HRCT와 안정시 폐기능 검사 및 운동부하 폐기능 검사간에 상호 관련성을 확인하여 보았다. 방 법 : 평균 연령 $60.6{\pm}10.3$세인 14명의 폐기종 환자들을 대상으로 HRCT, 안정시 폐기능 검사(forced expiratory flow volume curve, lung volumes by He dilution method, DLco, ABGA), 그리고 점진적운동부하폐 기능검사(incremental cycle ergometer)를 시행하였으며 HRCT는 GE highlight를 이용하여 조영증강 없이 최대흡기시에 1.5mm collimation, 10mm 간격으로 폐전체를 스캔하였고, 환자마다 모든 스캔에서 density mask를 이용하여 -400 HU를 기준으로 한 총폐면적과 -900 HU를 기준으로 한 폐기종 면적을 각각 구하여 백분율로 환산하여 폐기종 점수를 구하였다. 결 과 : 평균 폐기종 점수는 $37.4{\pm}14.9%$ 이었다. 폐기종 점수와 안정시 폐기능 검사의 DLco(r=-0.75)와 $PaO_2$(r=-0.66) 사이에서만 유의한(p<0.05) 상관성이 관찰되었다. 반면 폐기종 점수와 운동부하폐기능 지표들간의 상관성은 최대 산소섭취량(r=-0.68), 혐기성 역치(V-slope method, r=-0.690), 최대운동부하(r=-0.74), 최대운동시 $O_2$ pulse(r=-0.73), 최대운동시의 생리적 사강비율 (r=0.80) 등과 높은 유의성 (p<0.01)을 나타내었다. 그러나 호흡예비율과 심박수 예비율간에서는 유의한 상관성이 없었고, pulse oxymeter로 측정한 산소포화도와의 상관성도 유의하지 않았다. 결 론 : 이상의 결과에서 폐기종의 병리학적 중증도를 잘반영한다고 알려진 HRCT 폐기종 접수는 폐기종에 의한 생리학적 장애를 잘 반영하는 운동부하 폐기능 검사의 주요 지표들과 유의한 상관성이 있음을 확인할 수 있었다.

  • PDF