• 제목/요약/키워드: Volume Efficiency

검색결과 2,126건 처리시간 0.031초

모터 구동형 인공심장의 설계 및 해석(II) 해석 (Design and Analysis of Motor-Driven Artificial Heart ( II );Analysis)

  • 천길정;한동철;민병구
    • 대한기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.855-868
    • /
    • 1991
  • 본 연구에서는 위에서 언급한바와 같은 제반사항들에 대해 이론적인 해석을 행하고, 그 결과를 이용하여 설계된 모델이 생체내에 이식될 수 있는 가능성의 여부를 판단하며 생체내에 이식 되었을 때의 성능과 생체에 미치는 영향등을 예측하고자 한다.

인공폐(산화기) 제작과 실험 (Design & Animal Experiment of Artificial Oxygenator)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제15권2호
    • /
    • pp.259-265
    • /
    • 1982
  • We have designed a new type of bubble oxygenator (KOREA-KIM VENOTHERM OXYGENATOR) made of PVC sheet and deforming mesh incorporated in the heat exchanger, and evaluated in experimental animal for the analysis of it`s efficiency. The Oxygenator has low priming volume with high flow rate up to 6 L/rain, and efficiency of heat exchanger was excellent as 1-$1.5^{\circ}C.$ using total cardiopulmonary bypass method under moderate to deep hypothermia. Average priming volume of 1317 ml with 30% hemodilution method was perfused with an average of 1.1-3.0 L/min.$M^2$of arterial blood and pure oxygen at a rate of 2-3.4 L/min for 49.6 minutes continuously in average. During total cardiopulmonary bypass, average $PaO_2$ was $159.8{\pm}60$mmHg, $PaCO_2$ $41.0{\pm}3$mmHg respectively under $SaO_2$ over 96% with systolic arterial pressure of 70 mmHg and CVP of 5-10 cm$H_2O$. Plasma free Hemoglobin was $7.0{\pm}4$ mg/dl with 25% drop of hemoglobin and hematocrit at the end of cardiopulmonary bypass. This KKV Oxygenator was observed to have excellent capabillty of oxygen and carbon dioxide gas transfer with small amount of blood trauma, and the efficiency of heat exchanger was satisfactory during cooling and rewarming of the bubbled blood. Disadvantages have included the somewhat poor deforming effect due to loose PVC fiber mesh, the extracompact character of Teflon filters, and the rough inner surface of the heat exchanger copper pipes.

  • PDF

개가식 도서관의 공간효율 제고 방안 -지역 대학도서관 서고 공간을 중심으로- (Space Efficiency Improvement for Open Access Library -Focused on Book-storage Space of Academic Libraries in Province Area-)

  • 안준석
    • 한국농촌건축학회논문집
    • /
    • 제17권4호
    • /
    • pp.67-74
    • /
    • 2015
  • Due to an inability to accommodate for the rapidly increasing number of printed materials, Korean academic libraries are facing serious space shortage problems. Very few academic institutions have the funds to expand existing libraries or construct new facilities in order to accommodate the influx of printed materials. Despite not having the luxury to create new space, many establishments continue to implement the open access system. Seeing that such a system is only user friendly when used in a spacious facility, the maintenance of the open access system is unreasonable. Only few libraries consider the space efficient closed access system which helps to resolve storage space shortage. In the current state of the problem, improving the efficiency to which books are stored in existing storage areas within a library facility is the only appropriate solution. Enacting methods to improve physical space utilization within a fixed volume library facility will undoubtedly diminish the space shortage issue at hand. In this article, several space efficiency improvement approaches are discussed. Methods of book storage plan re-layout (floor, plan, ceiling, height, bookshelf design), book arrangement possibilities, and the reduction of the physical volume of reserved materials are each examined.

인공습지 기본형상에서 전산유체역학을 이용한 사류구간 및 입자제거율 평가 (Evaluation of hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland using computational fluid dynamics)

  • 최영균;박민철
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.495-502
    • /
    • 2013
  • Hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland was evaluated with computational fluid dynamics (CFD). The fraction of hydraulic dead-zone was estimated to be 1.2-2.1 % (v/v) and it was attributed to the artificial islands developed in the constructed wetland. Solids deposition rate could be increased with higher hydraulic retention time (HRT, ranged from 2.2 to 4.2 hr) of the wetland and larger particle size (ranged from 10 to $50{\mu}m$) in the influent. Experimental results showed that the volume concentration of the particles smaller than $10{\mu}m$ in diameter was varied from $1.99{\times}10^3{\mu}m^3/ml$ (HRT 12.8 hr) to $3.92{\times}10^3{\mu}m^3/ml$(HRT 2.2 hr) in the influent of the constructed wetland. With the effluent volume concentration data, removal efficiency of those particles was calculated to be 71.2 and 24.7 % when the HRT was 12.8 and 2.2 hr, respectively. Similar trend with the HRT variation could be identified with CFD analysis.

유기물부하가 낮은 하수의 전달탈질공법에 의한 탈질방안 (The Study on denitrification of low organic loading sewage by pre-denitrification process)

  • 이철승;서종환;김진우
    • 한국환경과학회지
    • /
    • 제13권9호
    • /
    • pp.779-878
    • /
    • 2004
  • This study was conducted to analyze the operating conditions of predenitrification process to improve the treatment efficiency in low organic loading sewage plant in use today, and to investigate the treatment efficiency of pilot plant added night soil as well as the nitrogen removal characteristics of pilot plant added carbon sources. In the operation under the condition of $BOD_{5}$ sludge load 0.03-0.28kg $BOD_{5}$/kg VSS/d and oxic ammoniac nitrogen sludge load 0.02-0.24 $kgNH_{4}^{+}$-N/kg MLVSS/d, nitrification efficiency is higher than 95%. In order to achieve 70% nitrogen removal at the T-N sludge loading 0.06kg T-N/kg VSSㆍd and the SRT 6~11 days, optimum operating factors were revealed to $CODc_{r}$/T-N ratio 9, recycle ratio 2.6, and denitrification volume ratio 0.33. At this time, denitrification capacity was approximately 0.09 kg $NO_{3}^{-}$-N/kg $CODc_{r}$; specific nitrification rate was 3.4mg $NH_{4}^{+}$-N/g MLVSS/hr; and specific denitrification rate was 4.8mg $NO_{3}^{-}$-N/g MLVSS/hr.

Emulsion liquid membranes for cadmium removal: Studies of extraction efficiency

  • Ahmad, A.L.;Kusumastuti, Adhi;Derek, C.J.C.;Ooi, B.S.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.11-25
    • /
    • 2013
  • Emulsion liquid membrane (ELM) process suffers from emulsion instability problem. So far, emulsion produced by mechanical methods such as stirrer and homogenizer has big size and high emulsion breakage. This paper discussed the application of emulsion produced by sonicator to extract cadmium in a batch ELM system. The emulsions consist of N,N-Dioctyl-1-octanamine (trioctylamine/TOA), nitrogen trihydride (ammonia/NH4OH), sorbitan monooleate (Span 80), and kerosene as carrier, stripping solution, emulsifying agent, and organic diluent, respectively. Effects of comprehensive parameters on extraction efficiency of Cd(II) such as emulsification time, extraction time, stirring speed, surfactant concentration, initial feed phase concentration, carrier concentration, volume ratio of the emulsion to feed phase, and pH of initial feed phase were evaluated. The results showed that extraction efficiencies of Cd(II) greater than 98% could be obtained under the following conditions: 15 minutes of emulsification time, 4 wt.% of Span 80 concentration, 4 wt.% of TOA concentration, 15 minutes of extraction time, 250 rpm of stirring speed, 100 ppm of initial feed concentration, volume ratio of emulsion to feed phase of 1:5, and initial feed pH of 1.53.

디젤엔진의 질소산화물 저감을 위한 Urea SCR 시스템 특성 분석 (II) (Characterization of SCR System for NOx Reduction of Diesel Engine (II))

  • 이준성;김남용
    • 한국정밀공학회지
    • /
    • 제25권11호
    • /
    • pp.83-89
    • /
    • 2008
  • The Effect of Space Velocity(SV) on NOx conversion rate was performed to develop NOx reduction after-treatment system. SV is calculated from engine exhaust gas volume and SCR catalyst volume. Found the Urea injection duty of maximum efficiency for NOx conversion if increase SV, NOx Conversion rate is down. Especially, when SV is more than $110,000h^{-1}$, NOx conversion rate decrease suddenly. Same case, if SV is lower than $40,000h^{-1}$, NOx conversion rate is down. Also, the characterization of Urea-SCR system was performed. Three candidate injectors for injecting Urea were tested in terms of 속 injection rate and NOx reduction rate. The performances of SCR catalytic converter on temperature were investigated. The performance of Urea-SCR system was estimated in the NEDC test cycle with and without EGR. It was found that nozzle type injector had high NOx conversion rate. SCR catalytic converter had the highest efficiency at the temperature of $350^{\circ}C$. EGR+Urea-SCR system achieved NOx reduction efficiency of 73% through the NEDC test cycle.

PDTF를 이용한 석탄가스화 특성 실험 (Pressurized Drop Tube Furnace Tests of Global Gasification Characteristics of Coal)

  • 신용승;최상민;안달홍
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.560-566
    • /
    • 1999
  • 가압 조건하에서의 석탄가스화 특성을 규명하기위해 , 온도 압력 , 산소/석탄비, 수증기/석탄비 등을 변화시켜가며 로토탄(sub A)에 대하여 PDTF(Pressuized drop tube furnace)실험을 수행하였다. 실험결과, 상압 조건에서보다 가압조건에서의 가스화가 탄소전환율과 냉가스효율의 측면에서 더 유리한 것으로 측정되었다. 최대의 냉가스효율을 보이는 산소/석탄비의 증가가 냉가스효율의 증가를 가져왔다. 압력이 증가할수록 열분해에 의한 탄소전환의 비중은 감소하고 대신 기고반응에 의한 탄소전환의 비중이 증가하였다.

  • PDF

PDTF를 이용한 석탄가스화 특성 실험 (Pressurized drop tube furnace tests of global gasification characteristics of coal)

  • 신용승;최상민;안달홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.23-31
    • /
    • 1999
  • 가압 조건하에서의 석탄가스화 특성을 규명하기 위해, 온도, 압력, 산소/석탄비, 수증기/석탄비 등을 변화시켜가며 로토탄(Sub A)에 대하여 PDTF(Pressurized drop tube furnace) 실험을 수행하였다. 실험결과, 상압 조건에서보다 가압조건에서의 가스화가 탄소 전환율과 냉가스효율의 측면에서 더 유리한 것으로 측정되었다. 최대의 냉가스효율을 보이는 산소/석탄비(무게기준)는 0.5∼0.7(g/g)로 측정되었고, 온도가 충분히 높은 경우에만 수증기/석탄비의 증가가 냉가스효율의 증가를 가져왔다. 압력이 증가할수록 열분해에 의한 탄소전환의 비중은 감소하고 대신 기고반응(heterogeneous reaction)에 의한 탄소전환의 비중이 증가하였다.

  • PDF

터빈과 압축기의 비단열 효율에 대한 열역학적 해석 (Thermodynamic Analysis of the Diabatic Efficiency of Turbines and Compressors)

  • 박경근
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.139-148
    • /
    • 2016
  • 터빈과 압축기의 1차 근사 모델을 대상으로 열역학적 해석을 하여 단열 효율의 특성을 파악하였다. 비단열 터빈과 압축기에 대해서는 엔트로피 평균 온도와 생성 엔트로피, 열원 온도, 열전달량 등의 값에 따라 단열 효율이 1보다 커질 수 있다. 즉, 단열 효율을 비단열 검사체적에 적용하면 실제보다 성능을 높게 평가하는 오류가 생길 수 있다. 이 문제를 해결하는 대안으로 실제 과정과 동일한 열이 전달되는 가역 비단열 과정을 이상 과정으로 채택하여 정의하는 비단열 효율을 제안한다. 이 비단열 효율은 항상 0과 1 사이에 있으며, 대부분의 경우 엑서지 효율보다 작음을 입증하였다. 비단열 효율은 단열 효율을 포함하는 더 일반적인 효율의 정의식으로 사용할 수 있다.