• Title/Summary/Keyword: Volume Efficiency

Search Result 2,126, Processing Time 0.023 seconds

Second law thermodynamic analysis of nanofluid turbulent flow in heat exchanger

  • K. Manjunath
    • Advances in Energy Research
    • /
    • v.8 no.3
    • /
    • pp.125-136
    • /
    • 2022
  • Entropy generation along with exergetic analysis is carried out using turbulent nanofluid flow in the heat exchanger. To obtain the optimized percentage constituent of nanofluid, the nanofluid volume concentrations is varied for the given input conditions. For different Reynolds number of the fluid and heat capacity rate ratio between the streams, the heat transfer improvements are studied in terms of nano particles diameter. Parametric analysis is carried out for a counterflow heat exchanger using turbulent nanofluid flow with exergetic efficiency along with entropy generation number as performance parameters. The exergetic efficiency provides realistic approach in the design of nanofluid applications in heat exchanger leading to conservation of energy.

Analysis of Permeation Efficiency in Soil for OPC and Non-Pollution MIS Grouts by Laboratory Model Test (실내모형시험을 통한 OPC와 친환경 MIS 그라우트의 지반 침투성능 분석)

  • Ahn, Jung-Ho;Lim, Heui-Dae;Choi, Dong-Nam;Song, Young-Su
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • In this paper, a laboratory model test was conducted to evaluate grouting efficiency of ordinary portland cement(OPC) and micro cement used in MIS(Micro-Injection Process System). For this research, a injection equipment was developed for pressure permeation which can evenly simulate various grouting tests in a laboratory and suggested a standard for the production of the test specimen. Using the injection device, the laboratory injection tests of grouts were prepared with water/cement ratio of 1:1, 2:1, 3:1, 4:1, and 5:1. The analysis of injection test for pressure permeation showed that the efficiency of injection increases linearly as the water/cement ratio increases. Comparison of efficiency of the injection indicates that MIS with a relatively smaller average diameter shows more efficient injection than the OPC. In the low ratio of water/cement as 2:1~1:1, the injection efficiency of OPC was especially poor. Also, a nonlinear grout volume-injection time is represented by a hyperbolic model and grout volume predicted by hyperbolic model was compared with the value measured. From the comparison, it shows that the hyperbolic model has the potential of evaluating the efficiency of grouting.

Study on the Improvement of Nitrate Removal Efficiency in Multi-Step Electro-chemical Process (전기화학적공정에서 질산성질소 제거효율 향상에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.155-160
    • /
    • 2008
  • In this study, the nitrate removal efficiency was examined under a variety of operating conditions, such as different doses of the reducing agent, different electrode types, different HRTs(hydraulic retention times), and different current densities, using the multistep electrochemical process. The nitrate removal efficiency increased and the input energy decreased when the reducing agent was used, and almost no difference was found between the electrode types in terms of their nitrate removal efficiency and current efficiency. So that the Zn reducing agent could be recovered, though, the B-type electrode was chosen(step 1: Pt-Zn; step 2: Pt-Zn; step 3: Pt-Zn; step 4: Pt-Zn). HRT experiments were carried out on constant electric current density unrelated HRTs and various electric current density related HRTs: the constant amount of electric current per unit volume. As a result, HRT and the electric current density caused concentration polarization and the lack of an applied current. That is to say,the lower the HRT, the greater the decrease in concentration polarization and in the amount of applied current per unit volume. Therefore, optimal conditions were found through the experiments that were conducted on HRT and electric current density. When a spacer was installed in the process, the nitrate removal efficiency and energy efficiency increased even more because the diffusion likewise increased.

A Study on Automatic Calculation of Earth-volume Using 3D Model of B-Rep Solid Structure (B-Rep Solid 구조의 3차원 모델을 이용한 토공량 자동 산정에 관한 연구)

  • Kim, Jong Nam;Um, Dae Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.5
    • /
    • pp.403-412
    • /
    • 2022
  • As the 4th industrial revolution is in full swing and next-generation ICT(Information & Communications Technology) convergence technology is being developed, various smart construction technologies are being rapidly introduced in the construction field to respond to technological changes. In particular, since the earth-volume calculation process for site design accounts for a large part of the design cost at the construction site, related researches are being actively conducted to improve the efficiency of the process and accurately calculate the earth-volume. The purpose of this study is to present a method for quickly constructing the topography of a construction site in 3D and efficiently calculating earth-volume using the results. For this purpose, the construction site was constructed as a 3D realistic model using large-scale aerial photos obtained from UAV(Unmanned Aerial Vehicle). At this time, since the constructed 3D realistic model has a surface model structure in which volume calculation is impossible, the structure was converted into a 3D solid model to enable volume calculation. And we devised a methodology to calculate earth-volume based on CAD(Computer-Aided Design and Drafting) using the converted solid model. Automatically calculating earth-volume from the solid model by applying the method. As a result, It was possible to confirm a relative deviation of 1.52% from the calculated earth-volume from the existing survey results. In addition, as a result of comparative analysis of the process time required for each method, it was confirmed that the time required is reduced of 60%. The technique presented in this study is expected to be utilized as a technology for smart construction management, such as periodic site monitoring throughout the entire construction process, as well as cost reduction for earth-volume calculation.

Enhancement of Dye-Sensitized Solar Cell Efficiency by Spherical Voids in Nanocrystalline ZnO Electrodes

  • Hieu, Hoang Nhat;Dao, Van-Duong;Vuong, Nguyen Minh;Kim, Dojin;Choi, Ho-Suk
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.458-464
    • /
    • 2014
  • Light scattering enhancement is widely used to enhance the optical absorption efficiency of dye-sensitized solar cells. In this work, we systematically analyzed the effects of spherical voids distributed as light-scattering centers in photoanode films made of an assembly of zinc oxide nanoparticles. Spherical voids in electrode films were formed using a sacrificial template of polystyrene (PS) spheres. The diameter and volume concentration of these spheres was varied to optimize the efficiency of dye-sensitized solar cells. The effects of film thickness on this efficiency was also examined. Electrochemical impedance spectroscopy was performed to study electron transport in the electrodes. The highest power conversion efficiency of 4.07 % was observed with $12{\mu}m$ film thickness. This relatively low optimum thickness of the electrode film is due to the enhanced light absorption caused by the light scattering centers of voids distributed in the film.

Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells (폐굴껍질에 의한 합성폐수 중의 인 제거)

  • 정경훈;정오진;최형일
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

Analysis of Industry Growth and Employment Effect in the Korean Manufacturing Sector by Regions (제조업종의 지역별 산업성장 및 고용효과 분석)

  • Koo, Hoonyoung;Min, Daiki
    • Korean Management Science Review
    • /
    • v.34 no.1
    • /
    • pp.15-25
    • /
    • 2017
  • We evaluated industry growth and employment effects of every possible pairs of 22 manufacturing sectors and 16 regions (i.e, 352 region-sectors). We used annual data of manufacturing sectors from 2008 to 2014 for the evaluation. The evaluation comprises of two steps; We first find several region-sectors that outperform others with respect to the effects of industry growth and employment, which are measured by location quotient analysis, shift share method, employment to GDP ratio and employment elasticity. In addition, cross-efficiency analysis follows to classify region-sector pairs into two sub-categories : efficient region-sectors that deserve to hold the current level of investments and inefficient region-sectors where we should consider efficiency improvements. To examine the efficiency, R&D investment, employment size, and capital investment were used as input factors and production volume, added value, changes in employment size, changes in annual salary per capita were used as output factors. For region-sector pairs that have outstanding growth and employment effects but are inefficient, we employed a CCR DEA model and analyzed how much to adjust the values of input and output factors to improve the efficiency scores. The analysis results showed that inefficiency is mainly due to several factors such as R&D investment, changes in employment size and changes in annual salary per capita.

Estimation of Cattle Wastewater Treatment using Singang Advance Biology Reactor (SAB) (SAB 고율미생물반응기를 이용한 축산폐수처리의 성능 평가)

  • Lim, Bongsu;Kim, Doyoung;Park, Sungsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.727-734
    • /
    • 2009
  • This study was carried out to evaluate the high rate biological reactor such as lab scale reactor before the application in site, and to get the basic data for possibility using liquid fertilizer with the effluent from biological reactor when the centrifugal machine was applied. The total volume of this reactor in 6 L, in composted of anoxic reactor (2 L), aerobic reactor (2 L), and nitification reactor (2 L). BOD removal efficiency rates when centrifugal machine was applied after effluent from biological reactor are over than 95%. This biological reactor was required post process to satisfy the effluent standards, and was need centrifugal machine to control the washout of microbes in the reactor. T-N removal efficiency rate in HRT 24 hr with centrifugation is 80.0%, and it is desirable to operate less than $1.3kgN/m^3{\cdot}d$ for 70% of T-N removal efficiency rate. T-P removal efficiency rate in HRT 24 hr is 68.2%, and become higher 71.3% after centrifugation. Considering in the 28.6% T-N removal efficiency rate, the nitrogen contents of the effluent from reactor is 0.34% to satisfy the liquid fertilizer.

Measuring Efficiency of Recycling Food Wastes Facilities using DEA (DEA 모형을 이용한 음식물류 폐기물 자원화 시설의 효율성 분석)

  • Kim, Dae-Hwan;Moon, Jong-Beom;Yoo, Wang-Jin;Lee, Dong-Myung
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.2
    • /
    • pp.212-224
    • /
    • 2010
  • After the introduction of Volume-based Waste Fee System for municipal wastes, the disposal of food wastes became an issue in society. As this reason, recycling food wastes facilities play an important role such as converting of food waste into animal feed or composting of food waste. Therefore, there is need of efficiency measurement of the facilities to reduce the inefficiency of factors. The purpose of this paper is to make a reasonable suggestion for the improvement of inefficient recycling food wastes facilities. This paper assesses the relative efficiency of recycling food wastes facilities by examining the relationship between inputs and outputs in 41 facilities using data envelopment analysis(DEA). The result shows that 4 facilities whose values of CCR efficiency are 1, and 10 facilities whose values of BCC efficiency are 1, RTS indicates IRS of 17 facilities and CRS of 6 facilities.

Development of Genetically Modified Tumor Cell Containing Co-stimulatory Molecule

  • Kim, Hong Sung
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.398-406
    • /
    • 2019
  • Cancer immunotherapy using gene-modified tumor cells is safe and customized cancer treatment method. In this study, we made gene-modified tumor cells by transferring costimulatory molecules, 4-1BBL and OX40L, into tumor cells using lentivirus vector, and identified anti-cancer effect of gene-modified tumor cells in CT26 mouse colorectal tumor model. We construct pLVX-puro-4-1BBL, -OX40L vector for lentivirus production and optimized the transfection efficiency and transduction efficiency. The transfection efficiency is maximal at DNA:cationic polymer = 1:0.5 and DNA 2 ㎍ for lentivirus production. Then, the lentiviral including 4-1BBL and OX40L was used to deliver CT26 mouse tumor cells to establish optimal delivery conditions according to the amount of virus. The transduction efficiency is maximal at 500 μL volume of lentiviral stock without change in cell shape or growth rate. CT26-4-1BBL, CT26-OX40L significantly inhibited the tumor growth compare with CT26-WT or CT26-β-gal cell line. These data showed the possibility the use of genetically modified tumor cells with costimulatory molecule as cancer immunotherapy agent.