• Title/Summary/Keyword: Volume Duration

검색결과 464건 처리시간 0.03초

정적연소기에서의 메탄-공기 혼합기의 연소특성(2) : 비균질급기 (Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(2) : Inhomogeneous Charge)

  • 최승환;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제11권4호
    • /
    • pp.29-36
    • /
    • 2003
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at spark plug and the combustion characteristics of inhomogeneous charge methane-air mixture under several parameters. The flow characteristics such as mean velocity and turbulence intensity was analyzed by hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer was used to investigate the effect of initial charge pressure, excess air ratio and ignition times on combustion pressure and combustion duration. Mean velocity and turbulence intensity had the maximum value at 200 or 300ms and then decreased to beneath 0.05m/s gradually at 3 seconds. Second mixture is accompanied by an increase in the combustion rate, and that the higher the mass which is added in the second stage injection, the faster the burn rate.

Volume change pattern of decompression of mandibular odontogenic keratocyst

  • Park, Jin Hoo;Kwak, Eun-Jung;You, Ki Sung;Jung, Young-Soo;Jung, Hwi-Dong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.2.1-2.6
    • /
    • 2019
  • Objectives: This study was aimed to analyze the reducing pattern of decompression on mandibular odontogenic keratocyst and to determine the proper time for secondary enucleation. Materials and methods: Seventeen patients with OKC of the mandible were treated by decompression. Forty-five series of CT data were taken during decompression and measured by using InVivo software (Anatomage, San Jose, Calif) and were analyzed. Results: The expected relative volume during decompression is calculated using the following formula: V(t) = Vinitial × exp.(at + 1/2bt2) (t = duration after decompression (day)). There was no significant directional indicator in the rate of reduction between buccolingual and mesiodistal widths. Conclusion: The volume reduction rate gradually decreased, and 270 days were required for 50% volume reduction following decompression of OKC. The surgeon should be aware of this pattern to determine the timing for definitive enucleation. Clinical relevance: The volume reduction rate and pattern of decompression of the OKC can be predicted and clinicians should be considered when treating OKC via decompression.

정적연소기에서 토치의 체적 변화에 따른 메탄의 연소특성 파악 (A Study on Combustion Characteristic Methane Fuel according to Torch Volume Variation in a Constant Volume Combustion Chamber)

  • 권순태;박찬준;엄인용
    • 한국가시화정보학회지
    • /
    • 제9권1호
    • /
    • pp.42-48
    • /
    • 2011
  • Six different size of torch-ignition device were applied in a constant volume combustion chamber for evaluating the effects of torch-ignition on combustion. The torch-ignition device was designed for six different volumes and same orifice size. The combustion pressures were measured to calculate the mass burn fraction and combustion enhancement rate. In addition, the flame propagations were visualized by shadowgraph method for the qualitative comparison. The result showed that the combustion pressure and mass burn fraction were increased when using the torch ignition device. And the combustion duration were decreased. The combustion enhancement rates of torch-ignition cases were improved in comparison with conventional spark ignition. Finally, the visualization results showed that the torch-ignition induced faster burn than conventional spark ignition due to the earlier transition to turbulent flame and larger flame surface, during the initial stage. Finally, the initial flame propagation was affected by torch-ignition volume.

5052-H32 알루미늄 합금의 통전 소성에 미치는 에너지밀도의 영향 검증 (Evaluation of Effect of Electric Energy Density on the Electroplasticity of 5052-H32 Aluminum Alloys)

  • 염경호;홍성태;정용하;한경식;한흥남;김문조
    • 대한기계학회논문집A
    • /
    • 제39권7호
    • /
    • pp.659-663
    • /
    • 2015
  • 본 연구에서는 다른 게이지 체적을 가지는 시편들의 동일한 에너지밀도 하에서의 통전소성 인장 거동을 실험을 통하여 비교하였다. 5052-H32 알루미늄 합금의 통전소성 인장실험의 결과는 시편의 게이지 길이나 폭 혹은 체적에 상관없이 동일한 에너지밀도가 가해질 때 거의 유사한 통전소성 특성을 보여준다. 특히 통전소성 인장시험의 전형적인 현상인 stress-drop 의 크기를 비교할 때, 소재의 통전소성이 개별적인 전류밀도와 통전시간이 아닌 에너지밀도에 의해서 영향을 받는다는 것을 확인할 수 있다. 본 논문의 결과는 통전소성 현상을 응용한 제조공정의 개발 시 공정설계변수들 중 전류밀도와 통전시간 두 가지를 에너지밀도 하나로 줄일 수 있다는 것을 의미하며 이는 향 후 다양한 통전소성 기반 제조기술의 개발에 이바지 할 것으로 예상된다.

Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction

  • Kim, Ki Jae;Chung, Jae Ho;Lee, Hyung Chul;Lee, Byung Il;Park, Seung Ha;Yoon, Eul Sik
    • Archives of Plastic Surgery
    • /
    • 제47권2호
    • /
    • pp.140-145
    • /
    • 2020
  • Background Capsular contracture is a common complication of two-stage expander/implant breast reconstruction. To minimize the risk of this complication, capsulectomy is performed using monopolar cautery or ultrasonic surgical instrumentation, the latter of which can be conducted with a Harmonic scalpel. To date, there is disagreement regarding which of the two methods is superior. The purpose of this study was to compare postoperative outcomes between a group of patients who underwent surgery using a Harmonic scalpel and another group treated with monopolar cautery. Methods A retrospective chart review was conducted of patients who underwent capsulectomy as part of two-stage breast reconstruction between January 2018 and February 2019 and who received at least 1 month of follow-up after surgery. Operative time and postoperative outcomes, including drainage duration, were analyzed. Results In total, 36 female patients underwent capsulectomy. The monopolar group consisted of 18 patients and 22 breasts, while the Harmonic scalpel group consisted of 18 patients and 21 breasts. There was no statistically significant difference in demographics between the two groups. The Harmonic scalpel group had a significantly shorter mean drainage duration (6.65 days vs. 7.36 days) and a smaller mean total drainage volume (334.69 mL vs. 433.54 mL) than the monopolar cautery group (P<0.05). No statistically significant difference was observed with regard to seroma or hematoma formation. Conclusions The Harmonic scalpel approach for capsulectomy reduced the total drainage volume and drainage duration compared to the monopolar cautery approach. Therefore, this approach could serve as a good alternative to electrocautery.

부하지속곡선(Load Duration Curve; LDC)을 이용한 한강수계 오염총량관리 목표수질 평가방법 적용 방안 (Application of the Load Duration Curve (LDC) to Evaluate the Achievement Rate of Target Water Quality in the Han-River Watersheds)

  • 김은경;류지철;김홍태;김용석;신동석
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.732-738
    • /
    • 2015
  • Water quality in four major river basin in Korea was managed with Total Maximum Daily Load (TMDL) System. The unit watershed in TMDL system has been evaluated with Target Water Quality (TWQ) assessment using average water quality, without considering its volume of water quantity. As results, although unit watershed are obtained its TWQ, its allocated loads were not satisfied and vice versa. To solve these problems, a number of TWQ assessments with using Load Duration Curve (LDC) have been studied at other watersheds. The purpose of this study was to evaluate achievement of TWQ with Flow Duration Curve (FDC) and Load Duration Curve(LDC) at 26 unit watersheds in Han river basin. The results showed that achievement rates in TWQ assessment with current method and with LDC were 50~56 % and 69~73%, respectively. Because of increasing about 20% of achievement rates with using LDC, the number of exceeded unit watershed at Han river Basin was decreased about 4~6 unit watersheds.

Use of a Temporary Shunt as a Salvage Technique for Distal Extremity Amputations Requiring Repair by Vessel Grafting during Critical Ischemia

  • Ince, Bilsev;Dadaci, Mehmet;Altuntas, Zeynep
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.544-550
    • /
    • 2016
  • Background Although the use of temporary shunts in proximal extremity amputations has been reported, no study has described the use of temporary shunts in distal extremity amputations that require vein grafting. Moreover, the total volume of blood loss when temporary shunts are used has not been reported. The aim of this study was to investigate the applicability of a temporary shunt for distal extremity amputations requiring repair by vessel grafting with an ischemia time of >6 hours. This study also aimed to determine the total volume of blood loss when temporary shunts were used. Methods Patients who underwent distal major extremity replantation and/or revascularization with a vessel graft and who experienced ischemia for 6-8 hours between 2013 and 2014 were included in the study. A 6-Fr suction catheter was cut to 5 cm in length after the infusion of heparin, and secured with a 5-0 silk suture between the distal and the proximal ends of the artery. While bleeding continued, the bones were shortened and fixed. After the complete restoration of circulation, the arterial shunt created using the catheter was also repaired with a vein graft. Results Six patients were included in this study. The mean duration of ischemia was 7.25 hours. The mean duration of suction catheter use during limb revascularization was 7 minutes. The mean transfusion volume was 7.5 units. No losses of the extremity were observed. Conclusions This procedure should be considered in distal extremity amputations requiring repair by vessel grafting during critical ischemia.

상시조사 교통량 자료의 결측 보정에 관한 연구 (A Study on Imputing the Missing Values of Continuous Traffic Counts)

  • 이상협;신재명
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.2009-2019
    • /
    • 2013
  • 교통량은 교통망 계획, 도로 설계, 도로 관리 등에 직접적으로 활용되는 중요한 기초자료이다. 교통량은 고정식 교통량조사 장비를 설치하여 연속적인 자료를 수집하는 상시조사와 특정일을 조사하는 수시조사로 구분되어 조사되고 있다. 상시조사의 경우 조사 지점에 설치되어 있는 장비의 고장이나 오작동 등으로 인하여 교통량 자료의 결측이 발생하며, 이러한 결측을 보정하기 위하여 다양한 방법이 적용되어 왔다. 본 연구에서는 결측 발생일 전 후의 자료를 활용하는 응용 지수평활화법을 제안하였으며, 평가 결과 교통량 변동계수가 낮은 경우 보정의 정확성이 제고됨을 알 수 있었다. 게다가 지점의 교통량 변동성이 결측 보정의 정확성에 영향을 미치는 중요한 요인으로 작용한다는 것을 확인하였다. 따라서 교통량 결측 보정의 신뢰성을 높이기 위해서는 지점별-시기별 결측 보정 방법이 달리 적용되어야 할 것이다.

유방재건술에 사용된 식염수 보형물의 임상적 내구성과 누출 (Clinical Durability and Deflation of Saline-Filled Breast Implant in Breast Reconstruction)

  • 김일국;이준호;김용하;김태곤;이수정;강수환
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.808-814
    • /
    • 2011
  • Purpose: Despite wide clinical use of breast implants, there is continued concern about the lifespan of these devices. The causes of explantation were infection, deflation of implant and patient's want. The deflation of saline-filled breast implant was related to strength and durability of implant shell. The purpose of this study is to evaluate the clinical durability of saline-filled breast implant through the analysis of duration until deflation occurred, causes, incidence and influencing factors. Methods: Retrospective analyses were conducted on clinical records for 19 cases of deflation of saline-filled breast implant from 201 cases of breast reconstruction with saline-filled implant between May 1995 and June 2011. The authors had been analyzed the causes of deflation, survival duration, symptom, sign, nipple excision, volume of implant, saline filling, method of reoperation, breast cancer stage and combined capsular contracture. Results: The causes of deflation were attributed to the cases that cannot be evaluated the causes in 15 cases, fall down in 1 case, mammography in 2 cases, accidental needle injury in 1 case. Mean survival duration was 4 years and 5 months. The duration of survival was less than 1 year for 5 cases, 1 year to 10 years for 10 cases, more than 10 years for 4 cases. The volume between 201 and 250 cc of deflated breast implant was rated as high by 14.0 percent. The deflation rate of underfilled implants was 11.4 percent, adequate filled implants was 9.3 percent. None of overfilled implant was deflated. The deflation of smooth surface implant was 5 of 152 cases. Textured implant was 14 of 49 cases. The capsular contracture of non-deflated breast implant was 28 of 182 cases and that of deflated breast implant was 6 of 19 cases. Conclusion: The patients who underwent saline-filled breast implant implantation should be informed that their implant could deflate. The analysis of clinical durability and causes of deflation in breast implant was important for the prediction and prevention of reopeation. The authors could suppose the causes of deflation of saline-filled breast implant through history, duration of survival, inspection of the shell of implant.

한국의 통관서비스 효율성 분석에 관한 연구 (Efficiency Analysis on Customs Clearance Service of Korea)

  • 이기웅
    • 무역상무연구
    • /
    • 제53권
    • /
    • pp.315-336
    • /
    • 2012
  • In year 2011 export volume of South Korea surpassed 500billion USD and overall trade volume has exceeded one trillion USD. South Korea is ranked at 7th in the world by its export volume. Such an expansion of the trade volume leads to growth in customs clearance service demand. However, there are only handfuls of studies on the efficiency of customs clearance service which customs broker provide. If the efficiency in this study is not absolute, it shows relative efficiency to decision making unit. In this research survey was conducted targeting members of Korea Customs Brokers Association. Based on the survey improvement plans to enhance efficiency of customs clearances are as follows. First, rationalize the customs broker fee. Second, setup batch processing system to improve efficiency of the work process. Third, develop new area of task such as FTA and AEO certification. Forth, raise service quality by improving professionalism of customs brokers. Fifth, work efficiency of the office in the capital area will increase. Sixth, when inspecting import export cargo, customs broker should attend at the scene by their choice. Meanwhile, difference analysis on competent customs, type of office, and duration of the business was done but all the aspects were rejected. Such aspects does not influence on its effectiveness.

  • PDF