Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application (소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.64-72
    • /
    • 2002
  • Purpose : To introduce and demonstrate the advantages of the new hybrid two-dimensional (2D) proton spectroscopic imaging (SI) over the single voxel spectroscopy (SVS) and conventional 2D SI in the clinical application of spectroscopy for pediatric cerebral disease. Materials and Methods : Eighty-one hybrid 2D proton spectroscopic imaging was performed in 79 children (36 normal infants and children, 10 with hypoxic-ischemic injury, 20 with toxic-metabolic encephalopathy, seven with brain tumor, three with meningoencephalitis, one with neurofibromatosis, one with Sturge-Weber syndrome and one with lissencephaly) ranging in age from the third day of life to 15 years. In adult volunteers (n=5), all three techniques including hybrid 2D proton SI, SVS using PRESS sequence, and conventional 2D proton SI were performed. Both hybrid 2D proton SI and SVS using PRESS sequence were performed in clinical cases (n=). All measurements were performed with a 1.5-T scanner using standard head quadrature coil. The 16$\times$16 phase encoding steps were set on variable field of view (FOV) depending on the size of the brain. The hybrid volume of interest inside FOV was set as $75{\times}75{\times}15{\;}\textrm{mm}^3$ or smaller to get rid of unwanted fat signal. Point-resolved spectroscopy (TR/TE=1,500 msec/135 or 270msec) was employed with standard chemical shift selective saturation (CHESSI pulses for water suppression. The acquisition time and spectral quality of hybrid 2D proton SI were compared with those of SVS and conventional 2D proton SI. Results : The hybrid 2D proton SI was successfully conducted upon all patients.

  • PDF

Effect of Soy Milk and Sugar Addition to Jeungpyun on Physicochemical Property of Jeungpyun Batters and Textural Property of Jeungpyun (증편 제조시 콩물과 설탕의 첨가가 반죽의 이화학적 성질 및 저장 중 증편의 품질에 미치는 영향)

  • Na, Han-Na;Yoon, Sun;Park, Hea-Won;Oh, Hea-Sook
    • Korean journal of food and cookery science
    • /
    • v.13 no.4
    • /
    • pp.484-491
    • /
    • 1997
  • The study was attempted to investigate physicochemical and biological changes that would occur during preparation of Jeungpyun (rice cake prepared with rice wine). Furthermore, the effect of soy milk and suga. addition to Jeungpyun batters on textural changes of Jeungpyun during storage was studied in relation to physicochemical properties of Jeungpyun batters. 1. As fermentation continued, PH of Jeungpyun batters droped from 6.01 to 4.36. The addition of soy milk and 10% sugar to Jeungpyun batters resulted in significantly lower PH during fermentation. The volume of the batters with soy milk were significantly larger than those without soy milk. Jeungpyun batters with soy milk showed dramatic increase in viscosity after 2 hours of fermentation and the viscosity of other groups increased after 3 and half hours of fermentation. The reducing sugar contents of Jeungpyun batters containing 20% sugar increased rapidly during first fermentation and then decreased. The reducing sugar contents of Jeungpyun batters containing 10% sugar increased gradually during first fermentation and then rapidly increased after addition of 10% sugar during 3rd fermentation. 2. Sensory evaluation results demonstrated that hardness of Jeungpyuns increased and tenderness, springiness, moistureness, overall acceptability decreased during storage of 4 days at 4$^{\circ}C$. QTS data showed that hardness, gumminess, chewiness of all the groups increased and adhesiveness decreased during storage. Both of sensory evaluation and QTS data demonstrated that addition of soy milk and separate addition of sugar at first and furing 3rd fermentation period induced slower changes in textural properties in Jeungpyuns during storage.

  • PDF

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

SUITABILITY OF SHELLFISHES FOR PROCESSING 3. Suitability of Pacific oyster for processing (패류의 가공적성 3. 굴의 가공적성)

  • LEE Eung-Ho;CHUNG Seung-Yong;KIM Soo-Hyeun;RYU Byeong-Ho;HA Jin-Hwan;OH Hoo-Gyu;SUNG Nak-Ju;YANG Syng-Tack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.2
    • /
    • pp.90-100
    • /
    • 1975
  • The estimation of the pre-processing condition of oyster is of great importance for distributors and processors. This study was attempted to establish the basic data for evaluating the processing suitability of oyster, which is the most important shellfish for domestic use and export. The data were analysed by measuring the condition index, chemical composition and heavy metal content of oysters. In order to eliminate the manual work that has to be done on a tightly closed oyster shell and avoid shrinkage in the oyster meat which is attendant on the steaming process, chemical means to open oyster were examined. finding the method of pretreatment of polyphosphate for frozen oysters were attempted to improve the product quality. The prevention of undesirable color change of the canned oyster meat is another problem to solve. The important results are as follows : 1. The ratio of meat volume and meat weight to the holding capacity by shells may be useful as an index to measure the condition index of oysters. 2. As a whole, monthly changes of moisture and fat content in oysters were reversely correlated. Protein content slightly decreased from April and rapidly decreased in July, and again rapidly increased in August but from September to November decreased slightly. In April, the content of glycogen was 4 percent. From this period to September, glycogen was rapidly decreased. From July to September, it was only 0. 7 to 1 percent but increased from October. There were little seasonal changes in pH value. The pH value of oyster meat was 6.0 to 6.2. The crude ash content was slightly decreased from June to August. 3. The range of monthly change of heavy metal content are as follows: Total mercury was 0 to 0.019 ppm, cadmium was 0.026 to 0.053 ppm, copper was 0.111 to 0.594 ppm, and lead_was 0.061 to 0.581 ppm. 4. By the results of condition index, chemical composition and heavy metal content of oysters, the suitable harvest season as raw materials for processing was the end of December to the end of May of next year. 5. The pretreatment of 10 percent polyphosphate in 5 percent salt solution of oyster meat appeared effective to reduce thawing drip during cold storage. 6. The pretreatment of $Na_2EDTA$ and BHA did not show the color prevention effect to the canned oyster meat during storage. 7. Magnesium chloride affected to open the valves of oysters.

  • PDF

Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance (선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성)

  • Lee, Jeong-Woo;Hong, Se-Mie;Park, Byung-Moon;Kang, Min-Young;Kim, You-Hyun;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.183-188
    • /
    • 2008
  • Aim of this study is to investigate the feasibility of 2D ion chamber array as a substitute of the water phantom system in a periodic Linac QA. For the feasibility study, a commercial ion chamber matrix was used as a substitute of the water phantom in the measurement for a routine QA beam properties. The device used in this study was the I'm RT MatriXX (Wellhofer Dosimetrie, Germany). The MatriXX consists of a 1,020 vented ion chamber array, arranged in $24{\times}24\;cm^2$ matrix. Each ion chamber has a volume of $0.08\;cm^3$, spacing of 0.762 cm. We investigated dosimetric parameters such as dose symmetry, energy ($TPR_{20,10}$), and absolute dose for comparing with the water phantom data with a Farmer-type ionization chamber (FC65G, Wellhofer Dosimetrie, Germany). For the MatriXX measurements, we used the white polystyrene phantom (${\rho}:\;1.18\;g/cm^3$) and also considered the intrinsic layer (${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm) of MatriXX to be equivalent to water depth. In the preliminary study of geometrical QA using MatriXX, the rotation axis of collimator and half beam junction test were included and compared with film measurements. Regarding the dosimetrical QA, the MatriXX has shown good agreements within ${\pm}1%$ compared to the water phantom measurements. In the geometrical test, the data from MatriXX were comparable with those from the films. In conclusion, the MatriXX is a good substitute for water phantom system and film measurements. In addition, the results indicate that the MatriXX as a cost-effective novel QA tool to reduce time and personnel power.