• Title/Summary/Keyword: Voltage utilization rate

Search Result 27, Processing Time 0.021 seconds

Analysis of Flow Rate Inducing Voltage Loss in a 100 cm2 Class Molten Carbonate Fuel Cell

  • Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • This work focuses on the behavior of the overpotential increase due to a utilization rise in a molten carbonate fuel cell. The behavior is generally explained by Nernst loss, which is a kind of voltage loss due to the thermodynamic potential gradients in a polarization state due to the concentration distribution of reactant species through the gas flow direction. The evaluation of Nernst loss is carried out with a traditional experimental method of constant gas utilization (CU). On the other hand, overpotential due to the gas-phase mass-transport resistance at the anode and cathode shows dependence on the utilization, which can be measured using the inert gas step addition (ISA) method. Since the Nernst loss is assumed to be due to the thermodynamic reasons, the voltage loss can be calculated by the Nernst equation, referred to as a simple calculation (SC) in this work. The three values of voltage loss due to CU, ISA, and SC are compared, showing that these values rise with increases in the utilization within acceptable deviations. When we consider that the anode and cathode reactions are significantly affected by the gas-phase mass transfer, the behavior strongly implies that the voltage loss is attributable not to thermodynamic reasons, namely Nernst loss, but to the kinetic reason of mass-transfer resistance in the gas phase.

Distributed Secondary Voltage Control of Islanded Microgrids with Event-Triggered Scheme

  • Guo, Qian;Cai, Hui;Wang, Ying;Chen, Weimin
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1650-1657
    • /
    • 2017
  • In this study, the distributed secondary voltage control of islanded microgrids with multi-agent consensus algorithm is investigated. As an alternative to a time-triggered approach, an event-triggered scheme is proposed to reduce the communication load among inverter-based distributed generators (DGs). The proposed aperiodic control scheme reduced unnecessary utilization of limited network bandwidth without degrading control performance. By properly establishing a distributed triggering condition in DG local controller, each inverter is only required to send voltage information when its own event occurs. The compensation of voltage amplitude deviation can be realized, and redundant data exchange related to fixed high sampling rate can be avoided. Therefore, an efficient use of communication infrastructure can be realized, particularly when the system is operating in steady state. The effectiveness of the proposed scheme is verified by simulations on a microgrid test system.

Characteristics of Nickel Oxide Thin Film Manufactured by Reactive Magnetron Sputtering Method (반응성 마그네트론 스퍼터링법에 의한 Nickel Oxide 박막 제작 특성에 관한 연구)

  • Kim, Gi-Bum;Hwang, Yun-Sik;Kim, Yeung-Shik;Park, Jang-Sick
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • In this paper, the DE(double erosion) cathode for the reactive magnetron sputtering system is developed for high deposition rate and high target utilization efficiency. The utilization efficiency of the developed DE cathode is 22% higher than that of normal SE(single erosion) cathode. Sputtering process for the nickel oxide thin films with the DE cathode is performed under the following conditions; power with $1kW{\sim}3kW$, pressure with 4mtorr and 8mtorr, oxygen flow ratio with $0%{\sim}80%$. As a result, the hysteresis phenomenon of discharge voltage in 4mtorr is lower than that in 8mtorr and the hysteresis phenomenon of discharge voltage is getting lower as the applied power is getting higher. The structure of cross section and surface roughness of the thin films are observed by FE-SEM and AFM. The structure of cross section of the thin films is columnar and the average surface roughness under oxygen flow ratio of 0%, 52.5% and 65.0% are $2.08{\AA}$, $2.20{\AA}$ and $0.854{\AA}$, respectively.

  • PDF

STUDIES ON PRODUCTION AND EFFICIENT UTILIZATION OF LIVESTOCK EMBRYOS BY IN VITRO FERTILIZATION AND MICROMANIPULATION IV. NUCLEAR TRANSPLANTATION AND ELECTROFUSION FOR CLONING IN BOVINE FOLLICULAR OOCYTES

  • Chung, Y.C.;Kim, C.K.;Song, X.X.;Yoon, J.T.;Choi, S.H.;Chung, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.6
    • /
    • pp.641-645
    • /
    • 1995
  • This study was conducted to develop a method for production of nuclear transplant bovine embryos using in vitro-matured (IVM) oocytes and to examine the effect of different conditions of electrofusion on fusion rate and developmental capacity of donor nucleus transplanted to enucleated oocytes. Eight- to sixteen-cell embryos derived from oocytes matured and fertilized in vitro used as donor blastomeres and IVM oocytes were used as recipient oocytes. Oocytes were enucleated immediately after 23-24 h IVM and then reconstituted with a donor blastomere in two different micromanipulation media. Fusion rate and subsequent development of the reconstituted oocytes was compared under the different electric stimuli and recipient oocyte ages. Success rate of enucleation was significantly higher in TCM-199 medium containing FCS than in DPBS. The high fusion rate(75-94%) and development (6.4-14.8%) to morulae and blastocyst (M + B) were obtained from 0.6-0.75 kV/cm DC voltage, although total cleavage was not different among the electric pulses. Most optimal condition of electric stimulation for fusion and development was 1 DC voltage of 0.75 kV/cm, in which 80.5% of oocytes were fused, 80.0% and 31.7% of which was cleaved and developed to M + B, respectively. No M + B was obtained from 1.2 kV/cm DC voltage regardless of pulse frequency. Recipint oocyte age at electrofusion greatly affected the cleavage and subsequent development to M + B, showing high rate at 40-41 h oocyte maturation. These results suggest that a suitable condition of electrofusion for donor nuclei derived from IVF may be 1-2 DC pulses of 0.7 kV/cm for $70{\mu}sec$ and that processing of a transplanted nucleus in IVM oocytes may be affected by maturation age of recipient oocytes.

Suppression of Circulating Current in Parallel Operation of Three-Level AC/DC Converters (병렬 3레벨 AC/DC 전력변환 시스템의 영상분 순환전류 억제)

  • Son, Young-Kwang;Chee, Seung-Jun;Lee, Younggii;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.312-319
    • /
    • 2016
  • Zero-sequence Circulating Current (ZSCC) flows inevitably in parallel converters that share common DC and AC sources. The ZSCC commonly flowing in all converters increases loss and decreases the overall capacity of parallel converters. This paper proposes a simple and effective ZSCC suppression method based on the Space Vector PWM (SVPWM) with the ZSCC controller. The zero-sequence voltage for the proposed SVPWM is calculated on the basis of the grid voltage and not on the phase voltage references. The limit of the linear modulation region of the converters with the proposed method is analyzed and compared with other methods, thereby proving that the limit of the region can be extended with the proposed method. The effectiveness of the proposed method has been verified through the experimental setup comprising four parallel three-level converters. The ZSCC is confirmed to be well suppressed, and the linear modulation region is extended simultaneously with the proposed method. Moreover, the proposed control method does not require any communication between the converters to suppress the ZSCC unlike other conventional methods.

Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance (전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.145-151
    • /
    • 2010
  • Voltage unbalance is regarded as a power quality problem of significant at the user application. Although the voltages are quite well balanced at the transmission system, the voltage level of utilization can be unbalanced due to the unequal system impedances and the unequal distribution of single phase loads. Capacitor is generally used for power-factor compensation and reducing harmonics of non linear load with reactor. If voltage unbalance exists, current unbalance is generated and it will be reflected in the capacity variance. When the reactor and condenser are used at the same location, generally its trouble rate is high. And it is very important checking out that how the variance of voltage, current and capacity of condenser is proceeded by the voltage unbalance. In this paper, we calculated that voltage, current and capacity of condenser are within the tolerance limit of official regulations in the event of voltage unbalance with/without reactor.

Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack (교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가)

  • Lim, H.C.;Seol, J.H.;Ryu, C.S.;Lee, C.W.;Hong, S.A.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 1995
  • A 100kW class stack consisting of 10 molten carbonate fuel cells has been fabricated. Internally manifold stack has been tested for endurance. Each cell in the stack had an electrode area of $100cm^2$ and reactant gases were distributed in each cells in a cross-flow configuration. Initial and long term operation performance of the stack was investgated as a function of gas utilization using a specially designed small scale stack test facility. It was possible to have a stack with an output of more than 100W using an anode gas of 72% $H_2/18%$ $CO_2/10%H_2O$ and cathode gas of 33% $O_2/67%$ $CO_2$ and 70% Air 30% $CO_2$. The output and voltage of the stack at a current 15A($150mA/cm^2$) and gas utilization of 0.4 showed 125.8W and 8.39V respectively by elapsed time of 310 hours operation. In long term operation characteristics, the voltage drop of 52.4mV/1000hour was observed after more than 1,840 hours operation. Among the voltage drop, the OCV loss was highest than other voltage loss such as internal resistance and electrode polarization. Non uniformity of 2voltages and degradation of cell voltage in the stack was observed in according to changing the utilization rate after a long term operation. Further work for increasing the performance prolonging the life of the stack are required.

  • PDF

Effect of Hydrogen Recirculation on the Performance of Polymer Electrolyte Membrane Fuel Cell with Dead Ended Mode (Dead ended 모드에서 수소 재순환이 고분자전해질연료전지의 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.531-538
    • /
    • 2019
  • As the performance of PEMFC has been improved, the water and heat generated by reaction have increased so, the water and heat management of PEMFC is becoming more important. In this study, hydrogen recirculation was applied as the water management technique and the effect of recirculation flow rate, purge interval and duration on the performance of PEMFC was investigated. Anode pressure, fuel humidity and utilization, water discharge amount was measured to check the effect of purge conditions on performance. As the recirculation flow rate has increased, the performance of PEMFC became lower due to decrease of anode outlet pressure. According to the purge conditions, instantaneous voltage drop has occurred because of accumulated water. In frequent purge conditions, the performance of PEMFC gradually decreased due to fuel humidity control failure. Stable performance and high fuel utilization was achieved on this work by analyzing the effect of purge conditions.

Operation Characteristics of 100W Class Molten Carbonate Fuel Cell Stack (100W 급 용융탄산염 연료전지 스택운전특성)

  • Lim, Hee-Chun;Lee, Chang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.94-96
    • /
    • 1994
  • To develop the 2kw class MCFC stack, preliminarly 3 cell and 10 cell stack having a $100cm^2$ effective electrode area were fabricated and tested. These stacks showed 30 W and 100 W of output respectively and average cell voltage of 0.734V at $150mA/cm^2$. The stack performance decreased with the increase of fuel utilization rate. In durability test of 10 cell stack, the performance was sharply decreased at the rate of 180mV/1000Hr during 720hours operation time.

  • PDF

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.