The Protection Method against the Operation under Unbalance Voltage in 3-phase Squirrel-Cage Induction Motor (3상절형유도전동기의 불평형운전에 대한 보호 방안)

  • 이은욱;박윤호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.281-288
    • /
    • 1984
  • A new method of protecting 3-phase squirrel-cage induction motor aginst burning-out by unbalance operation is proposed. This paper studied various kinds of situations occurred by unbalance operating in 3-phase induction motor, and we provided the search coils in the slots of stator and rotor for the purpose of detecting electrical phenpmena during unbalance operation. Through experiments, we find that search coils in the slots of stator is effective method for protecting the induction motor from unbalance operating.

  • PDF

The Measurement & Analysis of Voltage Unbalance Factor at LV Customer of Three-Phase Four-Wire System (3상 4선식 저압 수용가의 전압 불평형률 측정 분석)

  • Kim, Jong-Gyeoum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.91-99
    • /
    • 2004
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase at 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But once in a while uneven load unbalance or unclean power quality lead some problems such as do-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with intermationally allowable voltage unbalance limits.

A Current Controller with the Compensation of the Input Voltage Unbalance and Distortion for Three Phase PWM Rectifier (전원전압의 불평형 및 왜곡 보상기능을 갖는 3상 PWM 정류기의 전류제어기)

  • Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.594-601
    • /
    • 2011
  • In this paper, a new current controller with the compensation of an unbalance and distorted grid voltages has been proposed. Generally, in the three-phase power system, single phase or nonlinear loads can be connected with the 3 phase linear load simultaneously on the same point of common coupling. Therefore, The source voltage unbalance and distortion problem can be occurred. Under these unbalance and distorted grid voltage conditions, the input current of 3 phase PWM rectifiers also have unbalance and distortion. In this paper, a current controller with the simple Model Reference Adaptive System based unbalance and distorted voltages observer is proposed to get a sinusoidal input current. The performance of the proposed algorithm is verified through the simulation and the experiment.

A New Control Algorithm for Instantaneous Voltage Sag Corrector (순시전압강하 보상기의 새로운 제어 기법)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation (불평형 부하 운전시 3상 유도발전기 특성 해석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

The measurement & Analysis of Voltage Unbalance Factor at Three Phase Four Wire Load System (3상 4선식 부하설비의 전압 불평형율 측정 및 분석)

  • Kim, Jong-Gyeum;Park, Young-Jin;Lee, Dong-Ju;Lee, Hwa-Su;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.15-17
    • /
    • 2004
  • Most of LV customer has been composed the 3-phase four wire system distribution system which is supplying simultaneously at the 1-phase & 3-phase load. In this system, the composition of the power apparatus system is simple rather than conventional separation mode of the 1-phase & 3-phase, But due to uneven load unbalance or unclean power quality, various kinds such as derating or power losses become an issue. In this paper, we measured and analyzed voltage and current waveform in the field, compared with internationally allowable voltage unbalance limits.

  • PDF

Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction (전원 불평형과 역률을 보상하는 직렬형 능동전력필터)

  • Jang, Jeong-Ik;Lee, Dong-Choon;Seok, Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.498-500
    • /
    • 2005
  • This paper presents a unified control scheme for series-type active power filters combined with shunt passive filters for the source voltage unbalance compensation and the power factor correction simultaneously. The power factor correction is achieved by controlling the amplitude of reactive power current in a series filter as zero in a synchronously rotating reference frame. The proposed algorithm successfully compensates the source voltage unbalance and the power factor. The validity of the proposed scheme has been verified by simulation for a 3-kVA hybrid active power filter system.

  • PDF

The measurement & Analysis of Voltage Unbalance Factor at LV Customer of Three-Phase Four-Wire System (3상 4선식 저압 수용가의 전압 불평형율 측정분석)

  • Kim, Jong-Gyeum;Park, Young-Jin;Lee, Eun-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.43-47
    • /
    • 2004
  • Most of LV customer has been composed the 3-phase four wire system distribution system which is supplying simultaneously at the 1-phase & 3-phase load. In this system, the composition of the power apparatus system is simple rather than conventional separation mode of the 1-phase & 3-phase, But due to uneven load unbalance or unclean power quality, various kinds such as do-rating or power losses become an issue. In this paper, we measured and analyzed voltage and current waveform in the field, compared with internationally allowable voltage unbalance limits.

  • PDF

Analysis on the Harmonic Characteristics of Nonlinear Load operated by Unbalance Voltage (불평형 전압 공급시 비선형 부하의 고조파 특성 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Lee, Dong-Ju;Lee, Hwa-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.696-698
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF