Uncertainty Analysis in Potential Transformer Calibration Using a High Voltage Capacitance Bridge

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kwon, Sung-Won;Kim, Myung-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.401-407
    • /
    • 2007
  • Precise absolute measurement of the errors in a potential transformer (PT) can be achieved using high voltage capacitance bridge (HVCB) and capacitive divider. The uncertainty in a PT measurement using the HVCB system was evaluated by considering the overall factors affecting during the calibration of a PT. The expanded uncertainties are found to be not more than $30{\times}10^{-6}$ for ratio and $30{\mu}rad$ for phase up to the primary voltage of $V_p=22kV$. For same PTs, the measured errors in KRISS (Korea Research Institute of Standards and Science) using our bridge are well coincide with those in NMIA (National Measurement Institute of Australia) and PTB (Physikalisch-Technische Bundesanstalt) within the corresponding uncertainties.

240 kV 고전압 변성기 국가표준 시스템 구축 (Establishment of National Standard System for 240 kV High Voltage Transformer)

  • 정재갑;권성원;이상화;강전홍;김명수;한상길;김윤형;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.164-169
    • /
    • 2008
  • National standard system for calibrating voltage transformer(VT) up to primary voltage of 240 kV have been established in 2005. The system consists of voltage source, regulating unit, VT testing unit, standard VT, VT under test and VT burden. To verify and validate the performance for 240 kV VT calibration system, the comparison with the National Measurement Institute of Australia(NMIA) has been performed using same VTs. The comparison results of the VTs mesured at the Korea Research Institute of Stansdards and Science(KRISS) are consistent with those measured at NMIA within 0.002 % for ratio error and 0.14 min for phase displacement in the primary voltage ranges of Vp = 3300 V - 22000 V with a secondary voltage of Vs = 110 V.

132 kV 초정밀 전압변성기(PT) 개발 및 안정도 평가 (Development of 132 kV Standard Potential Transformer and Stability Test)

  • 권성원;이상화;정재갑;김문석;김재영;이성하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1387_1388
    • /
    • 2009
  • High accurate and stable 132 kV potential transformers (PTs) including 66 kV & 22 kV PT with stability of less than 0.0033 % for 13 month and with ratio error within $\pm$ 0.024 % at full rated voltage have been developed. The PTs are useful as the reference PT of the PT comparator system in the voltage range of 11 kV to 132 kV PT.

  • PDF