• 제목/요약/키워드: Voltage transformer

검색결과 1,683건 처리시간 0.04초

결합계수형 등가회로에 의한 변압기의 특성해석 (Analysis of Characteristics in Transformer by using Coupling Coefficient Type Equivalent Circuit)

  • 이광직;김주홍
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.86-92
    • /
    • 1995
  • In the analysis of characteristic behaviors of a real transformer with coupling coefficient K is less than 1, this paper presents the more accurate and practical profits than the traditional analysis of the transformer treated as K∼1. This results from the use of the coupling coefficient type equivalent circuit of the transformer which includes K as positive parameter. Furthermore, a leakage transformer is analyzed in a unified method and the results of analysis are consistent with the practical measurements of the transformer. By using the above equivalent circuit, the characteristics referred to the load side are expressed as Thevenin voltage source and the leakage inductor (1-K2)L2. Therefore, these analysis about the output voltage and the damping factor in the transient state which are affected by the leakage inductor are confirmed to be an effective method.

  • PDF

저온소결 PCW-PMN-PZT 세라믹스를 적용한 압전변압기의 전기적 특성 (Electrical Characteristics of Piezoelectric Transformer using Low Temperature Sintering PCW-PMN-PZT Ceramics)

  • 정광현;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.350-356
    • /
    • 2006
  • In this study, piezoelectric transformer was manufactured at the sintering temperature of $950^{\circ}C$, and then the feasibility of application to low temperature sintering piezoelectric transformers was investigated by evaluating the electrical characteristics of it. The voltage ratio of piezoelectric transformer showed the maximum value at the resonant frequency of input part, and increased according to the increase of load resistance. The output power and efficiency of piezoelectric transformer showed the superior properties when the output impedance of it coincides with the load resistance. Piezoelectric transformer manufactured at the low temperature of $950^{\circ}C$ showed the heat generation less than $20^{\circ}C$ at the output power of 30 W, and stable driving characteristics.

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

LCD 백라이트용 트랜스포머 없는 냉음극관(CCFL) 구동 회로 (Transformer-less CCFL Driver for LCD Backlight)

  • 최은석;윤현기;문건우;윤명중;강문식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.81-83
    • /
    • 2006
  • The conventional cold cathode fluorescent lamp (CCFL) driver for LCD TV has a transformer for each lamp to step up the high sinusoidal waveform from the low input voltage. The transformer used in the conventional topology causes the driver to have bulky size and high cost. This paper proposes a new transformer-less CCFL driver for LCD backlight that is based on the parallel-loaded resonant inverter topology. This resonant topology enables the circuit to supply enough high voltage for CCFL without a transformer. Also, with current-balancing technique, this transformer-less inverter drives 16 CCFL lamps.

  • PDF

변압기 용량을 고려한 수용률 산출 시뮬레이터 개발에 관한 연구 (A Study on Simulator for Computing Demand Rate Considering a Transformer Capacity)

  • 김영일
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.179-185
    • /
    • 2007
  • In this paper, the method of computing demand rate with respect to a transformer capacity is proposed and addressed to predict a future demand rate. The simulation data are taken from switchgears of a real medium voltage transformer. Data taken from the electrical instrument at 22.9 kVY power receiving panels are employed to evaluate the correlation between demand rate and power usage of transformer. It is verified a usefulness with respect to an proposed index of demand rate for transformer by using a least square error of regressive modeling, As a result of investigation and simulation on the spot to a few buildings, it is considered that there is necessity to make a partial amendment of demand rate being applicable currently for electrical energy saving in domestic.

형광등을 점타용 압전트랜스포머의 특성에 관한 연구 (A study on the Characteristic of Piezoelectric Transformer for the Fluorescent Lamp ballast)

  • 이용우;윤광희;류주현;서성제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.621-625
    • /
    • 1999
  • Rosen type piezoelectric transformer for LCD backlight operated at high voltage and low current, may not be sucessfully used for illuminating general fluorescent lamps because low voltage and high current are required. In this study, the piezoelectric transformer with width vibration mode operated at low voyage and high current was designed for the application of fluorescent lasso ballast. The step-up ratio and efficiency as a function of the load resistance in the piezoelectric transformer indicated that the transformer can be effectively used for the electronic ballast for low profile fluorescent lamp.

  • PDF

Analysis and Design of Transformer Windings Schemes in Multiple-Output Flyback Auxiliary Power Supplies with High-Input Voltage

  • Meng, Xianzeng;Li, Chunyan;Meng, Tao;An, Yanhua
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1122-1132
    • /
    • 2019
  • In this paper, aiming at high-voltage applications, transformer windings schemes of multiple-output two-transistor flyback converters are investigated, which are mainly based on the stray capacitances effect. First, based on a transformer model including equivalent stray capacitors, the operational principle of the converter is presented, and the main influence of its stay capacitors is determined. Second, the windings structures of the transformer are analyzed and designed based on the stray capacitances effect. Third, the windings arrangements of the transformer are analyzed and designed through a coupling analysis of the secondary windings and a stray capacitance analysis between the primary and secondary windings. Finally, the analysis and design conclusions are verified by experimental results obtained from a 60W laboratory prototype of a multiple-output two-transistor flyback converter.

고출력 펄스응용을 위한 고전압 펄스변압기 최적설계 (Design Optimization of High-Voltage Pulse Transformer for High-Power Pulsed Application)

  • 장성덕;강흥식;박성주;한영진;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1297-1300
    • /
    • 2008
  • A conventional linear accelerator system requires a flat-topped pulse with less than ${\pm}$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A pulse transformer is one of main determinants on the output pulse voltage shape. The pulse transformer was investigated and analyzed with the pulse response characteristics using a simplified equivalent circuit model. The damping factor ${\sigma}$ must be >0.86 to limit the overshoot to less than 0.5% during the flat-top phase. The low leakage inductance and distributed capacitance are often limiting factors to obtain a fast rise time. These parameters are largely controlled by the physical geometry and winding configuration of the transformer. A rise time can be improved by reducing the number of turns, but it produces larger pulse droop and requires a larger core size. By tradeoffs among these parameters, the high-voltage pulse transformer with a pulse width of 10 ${\mu}s$, a rise time of 0.84 ${\mu}s$, and a pulse droop of 2.9% has been designed and fabricated to drive a klystron which has an output voltage of 284 kV, 30-MW peak and 60-kW average RF output power. This paper describes design optimization of a high-voltage pulse transformer for high-power pulsed applications. The experimental results were analyzed and compared with the design. The design and optimal tuning parameter of the system was identified using the model simulation.

  • PDF

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

A Simplified Unified Model for Predicting the Dielectrophoretic Aactivity of Magnetic Nanoparticles Aimed at Enhancing the Dielectric Characteristics of Transformer Oil

  • 이종철;전홍필
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.431.2-431.2
    • /
    • 2014
  • The dielectric breakdown voltage (DBV) is a measure of an insulating fluids ability to withstand a high electric field stress without breaking down. Conventionally, the presence of water or particulate matter in a dielectric fluid comprises the liquid's breakdown strength. However, the addition of magnetic nanoparticles (MNPs) in the base oil can increase the dielectric breakdown voltage of the fluid reversely, if the condition of the added particles in the fluid is in balance with that of keeping down the initiation and propagation of electrical streamers. In this study, we developed a mathematical model by a set of coupled, nonlinear equations using the COMSOL multiphysics finite element simulation suite and calculated the dielectrophoretic activity of magnetic nanoparticles suspended in the presence of electric field, which is the behavior responsible for enhancing the dielectric characteristics of transformer oil, in order to examine how the activity differ in a transformer oil-based magnetic fluid.

  • PDF