• 제목/요약/키워드: Voltage sag detection

검색결과 48건 처리시간 0.028초

An Improved Detection Technique for Voltage Sag using the Wavelet Transform

  • Kim, Chul-Hwan;Lee, Jong-Po;Ahn, Sang-Pil;Kim, Byung-Chun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.1-8
    • /
    • 2001
  • This paper presents a discrete wavelet transform approach for detecting voltage sags initialized by fault conditions and starting of larger motors. The proposed technique is based on utilizing the summation value of D1(at scale 1) coefficients in multiresolution analysis(MRA) based on the discrete wavelet transform. In this paper, the proposed technique is tested under various cases of voltage sags. It is shown that the voltage sag detection technique based on the wavelet transform is a satisfactory and reliable method for detecting voltage sags in power quality disturbance analysis.

  • PDF

Voltage sag의 특성과 dq좌표변환을 이용한 검출법에 대한 연구 (The Characteristics of Voltage Sag and a Study about Detection Algorithm Using the DQ Transformation)

  • 김용상;김도훈;임상욱;이교성;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1114-1116
    • /
    • 2003
  • Voltage sags are known as a serious problem causing mal-operation of equipment like computers, process controllers and adjustable-speed drives. In this paper, characterization of voltage sag and an overview of methods used in the mitigation of voltage sags are presented. Moreover a fast detection method for voltage disturbances is explored. The algorithm is based on the theory that allows a set of three-phase voltages be converted the d-q value. The utility input voltages are sensed and then converted to some quantities in the d-q transformation. And the difference between reference value and input value are showed that some disturbances happened in the system.

  • PDF

전력선 계통의 순시 전압 강하 제어기 설계 (Instantaneous Voltage Sag Corrector Controller Design of Power Line System)

  • 이상훈;홍현문
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.6-11
    • /
    • 2006
  • 본 논문은 전력품질 향상을 목적으로 VSC의 새로운 제어 기법의 디자인에 대하여 기술하였다. 전압강하의 빠른 검출 기술은 동기 회전 d q-기준축에서 순시값의 검출을 통해서 구현되었다. 1차 디지털 필터는 노이즈에 대하여 둔감한 특성을 막을 수 있는 검출 알고리즘을 부가하였다. 필터의 전체 검출과 컷오프 주파수 사이에서 관계에 대하여 기술하였다. 에너지 저장 요소로서 사용되는 캐패시터 뱅크의 사이즈는 회로 해석으로서 입 출력 에너지의 관점에서 디자인 되었다. 마지막으로, 제안된 기법의 유효성은 모의실험을 통하여 증명되었다.

전압강하 검출을 이용한 동적전압보상기의 실계통 적용 (Dynamic Voltage Restorer Applied to Real Power System using Voltage Sag Detection)

  • 이현우;박정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.203-204
    • /
    • 2015
  • 본 논문은 실제 전력계통을 모의한 A계통에서 3상 지락 사고가 발생하였을 때, 순시 전압강하를 보상하기 위한 동적전압보상기(Dynamic Voltage Restorer)의 동작에 따른 해당 부하의 영향성을 연구하였다. 동적전압보상기의 동작을 위한 전압강하 검출은 RMS Detection 기법을 통해 구현하였으며, IEEE Standard 1159-1995의 기술된 Voltage Sag의 정의에 따라 동적전압보상기의 on/off 제어를 수행하였다. A계통 모델링을 포함한 모든 시뮬레이션은 PSCAD/EMTDC 상에서 구현하였으며, RMS 전압 측정 및 Voltage Sag 검출 신호, 그리고 동적전압보상기의 동작 전 후에 따른 순시 부하전압 파형을 결과로 다룰 것이다.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Detection of Voltage Sag using An Adaptive Extended Kalman Filter Based on Maximum Likelihood

  • Xi, Yanhui;Li, Zewen;Zeng, Xiangjun;Tang, Xin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1016-1026
    • /
    • 2017
  • An adaptive extended Kalman filter based on the maximum likelihood (EKF-ML) is proposed for detecting voltage sag in this paper. Considering that the choice of the process and measurement error covariance matrices affects seriously the performance of the extended Kalman filter (EKF), the EKF-ML method uses the maximum likelihood method to adaptively optimize the error covariance matrices and the initial conditions. This can ensure that the EKF has better accuracy and faster convergence for estimating the voltage amplitude (states). Moreover, without more complexity, the EKF-ML algorithm is almost as simple as the conventional EKF, but it has better anti-disturbance performance and more accuracy in detection of the voltage sag. More importantly, the EKF-ML algorithm is capable of accurately estimating the noise parameters and is robust against various noise levels. Simulation results show that the proposed method performs with a fast dynamic and tracking response, when voltage signals contain harmonics or a pulse and are jointly embedded in an unknown measurement noise.

Fast Detection Algorithm for Voltage Sags and Swells Based on Delta Square Operation for a Single-Phase Inverter System

  • Lee, Woo-Cheol;Sung, Kook-Nam;Lee, Taeck-Kie
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.157-166
    • /
    • 2016
  • In this paper, a new sag and peak voltage detector is proposed for a single-phase inverter using delta square operation. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on d-q transformations using an all-pass filter (APF). The d-q transformation is typically used in the three-phase coordinate system. The APF generates a virtual q-axis voltage component with a 90° phase delay, but this virtual phase cannot reflect a sudden change in the grid voltage at the instant the voltage sag occurs. As a result, the peak value is drastically distorted, and it settles down slowly. A modified APF generates the virtual q-axis voltage component from the difference between the current and the previous values of the d-axis voltage component in the stationary reference frame. However, the modified APF cannot detect the voltage sag and peak value when the sag occurs around the zero crossing points such as 0° and 180°, because the difference voltage is not sufficient to detect the voltage sag. The proposed algorithm detects the sag voltage through all regions including the zero crossing voltage. Moreover, the exact voltage drop can be acquired by calculating the q-axis component that is proportional to the d-axis component. To verify the feasibility of the proposed system, the conventional and proposed methods are compared using simulations and experimental results.

3상 불평형 계통에서의 상 전압 보상을 통한 Sag 및 Swell 검출 (Sag & Swell Detection by Phase Voltage Compensation in 3-Phase Unbalanced Grid)

  • 김민기;김준구;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.258-259
    • /
    • 2013
  • Load connection or disconnection makes instantaneous sag & swell in 3-phase grid. When unbalance state occurs, between sensed phase voltage and actual phase voltage may have discrepancy. It makes difficult to detect accurate sag & swell, so it is hard to satisfy the standard for switching ESS system to UPS mode. In this paper, we analyzed unbalanced 3-phase voltage, and compensated the actual sag & swell magnitude.

  • PDF

단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구 (The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.

개선된 전압 Sag 및 위상 검출기법에 의한 동적전압보상시스템 (Dynamic Voltage Restorers using Improved Voltage Sag and Phase Detection Algorithm)

  • 이재영;한운동;송양회;손진근;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.185-188
    • /
    • 2005
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Dynamic voltage restorers(DVR) are known as the best effective and economic means to compensate for power quality problems(especially, voltage sag and swell). In this paper, we addresses the detecting algorithms of an voltage sag and phase for operating DVR. Experimental results are included to illustrate the efficacy of the proposed algorithm.

  • PDF