• 제목/요약/키워드: Voltage restoration

검색결과 60건 처리시간 0.02초

DVR(Dynamic Voltage Restorer)에서의 직류에너지 제어 방법 (The DC Link Energy Control Method of Dynamic Voltage Restorer System)

  • 정일엽;박상영;원동준;문승일;박종근;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.575-583
    • /
    • 2001
  • Dynamic Voltage Restorer(DVR) which is installed between the supply and a critical load can restore voltage disturbances in distribution system. The restoration is based on injecting the same voltages as voltage sags. The ideal restoration is compensation to make the load voltages be unchanged. But voltage restoration involves real power or energy injection and the capability of energy storage is limited. So it must be considered how injection energy can be minimized and voltages can be made close to the voltages before fault. This paper describes conventional restoration techniques, which draw minimum energy from the DVR in order to correct a given voltage sag or swell. And this paper proposes a new concept of restoration technique to inject minimum energy. The proposed method is based on the definition of voltage tolerance in load side. Hence using the proposed method a particular disturbance can be corrected with less amount of storage energy compared to those of conventional methods.

  • PDF

시송전계통의 고조파 공진현상에 대한 분석 (Analysis of the Harmonic Resonance during Restoration of Primary Restorative Transmission System)

  • 이경섭;이흥재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권5호
    • /
    • pp.191-194
    • /
    • 2006
  • Power system restoration following a wide area or complete blackout starts with energizing primary restorative transmission systems. During this primary restoration process, unexpected over-voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. Since the harmonic resonance originates from the nonlinear characteristics, it is very difficult to predict the occurrence of this phenomenon. This paper reports the analyses of the harmonic resonance occurred in domestic power system. Various analyses and results of the harmonic over-voltage is presented based on the PSCAD/EMTDC simulations.

P-채널 MOSFET에서 게이트와 기판 전류의 시간에 따른 복원 특성 (Restoration Characteristics along to Time of the Gate and Substrate Current in p-channel MOSFETS)

  • 조상운;장원수;배지철;이용재
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1101-1104
    • /
    • 2003
  • In this paper, we analyzed the gate current and substrate current by the hot carrier effects and restoration phenomenon of characteristics by time in the p-channel MOSFETs. The Stress voltage condition is a voltage in maximum gate current and time is 3s, 10s, 30s, l00s, 1000s, 2000s and 3000s. As results of analysis, the gate current and substrate current were decreased by stress time, and the restoration time of characteristics were shown the results that were decreased by the exponential times.

  • PDF

시송전계통 탁구과정에서의 고조파 공진 현상에 대한 고찰 (Analysis of the Harmonic Resonance during Restoration of Primary Restorative Transmission System)

  • 이홍재;이경섭;박성민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2005
  • Power system restoration following a wide area or complete blackout starts with energizing primary restorative transmission systems. During this primary restoration process, unexpected over-voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. Since the harmonic resonance originates from the nonlinear characteristics, it is very difficult to predict the occurrence of this phenomenon. This paper reports the possible existence of the harmonic resonance in Korean power system. Analysis of the harmonic over-voltage is presented based on the various simulations using PSCAD/EMTDC.

  • PDF

이더넷 통신기반의 자율적 고장 판단 및 복구 방법론 연구 (The Self-Fault Determination and Restoration Methodology based on the Ethernet Communication)

  • 고윤석;이서한;최현철;신재현
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1674-1680
    • /
    • 2009
  • This paper proposes an autonomous fault determination, fault zone isolation and fault restoration strategy based on the ethernet communication as a new attempt to solve the problem the of the existing central control method. In proposed method, The FRTU(Feeder Remote Terminal Unit)s on the feeder determines autonomously where the faulted zone is by exchanging the voltage and current information with neighbor FRTUs based on the network communication, and then separates the faulted zone in an nil-voltage status to make the protective device to reclose successively. In particular, the minimization of outage time and relational load balancing is archived by each interconnection switch which determines autonomously the load zone to be allocated among those zones after the sound outage zones was separated individually. Finally, to show effectiveness of the proposed fault restoration strategy, the several fault cases are simulated for the test distribution system, and the load balancing index of the proposed solution is compared with all of feasible solutions.

자기여자(Self-Excitation) 방지를 고려한 시송전 선로에 관한 연구 (Analysis Of The Primary Restorative Transmission System To Prevent Self-excitation)

  • 이흥재;김상섭;박성민;황봉환;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.44-46
    • /
    • 2002
  • Service restoration following a complete or partial collapse starts with reenergize a transmission line from black-start generators. Voltage problems can arise by Ferranti effect as unloaded transmission line is reenergized. This paper presents analytical results on the primary restorative transmission system focused on the voltage problem during the early restoration process. Methodologies to handle load pick-up compensating Ferranti effect. and terminal voltage and reactive capability limitation of black-start generators about self-excitation are presented. An algorithm for static analysis about these methodologies is developed, and EMTDC simulation for verifying the efficiency of the algorithm is performed.

  • PDF

고조파 공진 억제를 위한 완충부하 투입량 분석에 관한 연구 (A Study on the Analysis of Damping Loads to Prevent Harmonic Resonance)

  • 임찬호;이경섭;유원근;이흥재
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.262-266
    • /
    • 2010
  • During the restoration process of primary restorative transmission system, the over voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This over voltage is caused by harmonic resonance and can be prevented by damping loads that are connected before restoration process of primary restorative transmission system. But it is very difficult to predict the occurrence possibility of the harmonic resonance previously. This paper analyzes the relationship between the harmonic resonance and the amount of damping loads to prevent the harmonic resonance. This paper calculates the minimum amount of damping loads to prevent harmonic resonance while changing the length of primary restorative transmission line. And this paper confirmed that the amount of damping loads is not proportional to length of transmission line. The result of this paper will be used as important experiment data to predict the occurrence possibility of harmonic resonance previously.

배전계통 사고복구 문제에 갠선된 유전 알고리즘 적용 (An Application of Enhanced Genetic Algorithm to solve the Distribution System Restoration Problem)

  • 이정관;문경준;황기현;서정일;이화석;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1123-1125
    • /
    • 1999
  • This paper proposes an optimization technique using Genetic Algorithm(GA) for service restoration in the distribution system. Restoration planning problem can be treated as a combinatorial optimization problem. So GA is appropriate to solve the service restoration problem in the distribution network. But searching capabilities of the GA can be enhanced by developing relevant repairing operation and modifying GA operations. In this paper, we aimed at finding appropriate open sectionalizing switch position for the restoration of distribution networks after disturbances using enhanced GA with repairing operation and modified mutation. Simulation results show that proposed method found the open sectionalizing switches with less out of service area and minimize transmission line losses and voltage drop.

  • PDF

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

배전 계통에서의 사고 복구를 위한 전문가 시스템 (An Expert System for Fault Restoration in Distribution System)

  • 최병윤;김세호;이윤섭;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.171-174
    • /
    • 1990
  • When load areas on a feeder are deenergized due to faults,operaters need to identify nelghboring feeders, try to restore customers and minimize out-of-service areas. These cases include knowledge of system states and various constraints such as voltage drop. This paper concerns the load transfer infault restoration. Also, it is considered the operating constraints such as line current capacity, relay trip current, transformer capacity, voltage drop and line loss. The expert system is able to propose the optimal load transfer method by anallzing system states and considering constraints.

  • PDF