• Title/Summary/Keyword: Voltage gradient

Search Result 140, Processing Time 0.03 seconds

Proton Transport in Human Placental Microvillous Membrane Vesicles

  • Ri, Ok-Kyung;Jung, Jin-Sup;Kim, Won-Whe;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.25 no.1
    • /
    • pp.49-60
    • /
    • 1991
  • The change of the acridine orange absorbance was used to monitor the formation and/or dissipation of a pH gradient in microvillous membrane vesicles (MVV) isolated from human term placenta. Under $Na^+$ efflux conditions, an acidification of the intravesicular space occured and it was completely inhibited by 0.1 mM amiloride. Under $K^+$ efflux conditions, an acidification of the intravesicular space occured and it was potentiated by valinomycin or FCCP. An inwardly directed chloride gradient also induced a minor intravesicular acidification, but it was not observed in voltage-clampled MVV. The initial rate of the dissipation of a pH gradient was accelerated by pulse injections of $Na^+$ in a saturable manner and $Li^+$ could replace $Na^+$. The kinetic parameter of $Na^+$ in placental $Na^+/H^+$ exchange was similar to that of renal $Na^+/H^+$ exchange. Amiloride was a inhibitor of directly coupled $Na^+/H^+$ exchange and its $IC_{50}$ in placental MVV was about 14-fold higher than that in renal brush border membrane. These results indicate that $Na^+/H^+$ exchanger exists in human placental MVV and that its kinetic characteristics is similar to that of renal $Na^+/H^+$ exchanger but its pharmacological characteristics is different. In placental MVV $K^+,\;H^+$, and, relatively minor chloride conductances are present. The magnitude of $Cl^-/OH^-$ exchange, even though it exists, seems to be smaller than that of $Na^+/H^+$ exchange.

  • PDF

Ceramic Actuators with PLZT Functionally Gradient Material (PLZT 경사 기능 재료를 이용한 세라믹 엑튜에이터)

  • Choi, Seung-Chul;Kim, Han-Soo;Sohn, Jeong-Ho;Kim, Hyun-Jai;Jeong, Hyeong-Jin
    • Korean Journal of Materials Research
    • /
    • v.1 no.2
    • /
    • pp.105-112
    • /
    • 1991
  • In PLZT system, a new type of material for piezoelectric actuator was developed and its properties were investigated. This material consists of three layers : a piezoelectric ceramic layer, an interlayer which composition changes gradually, and another piezoelectric layer. This kind of materials is called functionally Gradient Materials(FGM). The composition of these layers were selected from the $(Pb,\;La)(Zr,\;TiO_3$ system through the concept of materials design. Sintered FGM at $1300^{\circ}C$, 2hr has an interlayer of about $20\mu\textrm{m}$ with no distorted damage. Dielectric and piezoelectic properties of FGM show intervalues of each side composition. The strain-voltage characteristics in FGM system was improved comparison with any single composition. Especially, the FGMs were fabricated which has high piezoelectric-low dielectric composition and low piezoelectric-high dielectric composition. The properties of both FGMs were significantly improved.

  • PDF

Thermal, electrical and mechanical buckling loads of sandwich nano-beams made of FG-CNTRC resting on Pasternak's foundation based on higher order shear deformation theory

  • Arani, Ali Ghorbanpour;Pourjamshidian, Mahmoud;Arefi, Mohammad;Arani, M.R. Ghorbanpour
    • Structural Engineering and Mechanics
    • /
    • v.69 no.4
    • /
    • pp.439-455
    • /
    • 2019
  • This research deals with thermo-electro-mechanical buckling analysis of the sandwich nano-beams with face-sheets made of functionally graded carbon nano-tubes reinforcement composite (FG-CNTRC) based on the nonlocal strain gradient elasticity theory (NSGET) considering various higher-order shear deformation beam theories (HSDBT). The sandwich nano-beam with FG-CNTRC face-sheets is subjected to thermal and electrical loads while is resting on Pasternak's foundation. It is assumed that the material properties of the face-sheets change continuously along the thickness direction according to different patterns for CNTs distribution. In order to include coupling of strain and electrical field in equation of motion, the nonlocal non-classical nano-beam model contains piezoelectric effect. The governing equations of motion are derived using Hamilton principle based on HSDBTs and NSGET. The differential quadrature method (DQM) is used to calculate the mechanical buckling loads of sandwich nano-beam as well as critical voltage and temperature rising. After verification with validated reference, comprehensive numerical results are presented to investigate the influence of important parameters such as various HSDBTs, length scale parameter (strain gradient parameter), the nonlocal parameter, the CNTs volume fraction, Pasternak's foundation coefficients, various boundary conditions, the CNTs efficiency parameter and geometric dimensions on the buckling behaviors of FG sandwich nano-beam. The numerical results indicate that, the amounts of the mechanical critical load calculated by PSDBT and TSDBT approximately have same values as well as ESDBT and ASDBT. Also, it is worthy noted that buckling load calculated by aforementioned theories is nearly smaller than buckling load estimated by FSDBT. Also, similar aforementioned structure is used to building the nano/micro oscillators.

A study on the way on energy efficiency of regenerative braking (전력회생 브레이크의 에너지 효율화 방안 연구)

  • Park, Young-Jin;Moon, Kwan-Il;Shin, Min-Sik;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.204-212
    • /
    • 2010
  • Currents which are generated at both ends of drive motor by operating brake pedal when subway train is driving, will generate the reviltalization actual effect if they are not used immediately. So there exist rolling stock established Dynamic braking annex for the purpose of stable brake performance in case there are no retrogress train around or no stable wiring voltage.Therefore 55% of entered energy are consumed in subway train. 45% are used in down gradient section or for regeneration energy and among them 25% are used for another train's retrogression through the wiring. So to reduce reviltalization method keeping the existing system, substation's service voltage should be declined about 5%. And then it will ease off excessive wiring voltage rise. And there need energy reduction by flexible service voltage adjustment and study for energy consumption efficiency in the subway.

  • PDF

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

Wet Flashover Characteristics and Reform Measure of a Conventional Lightning Rod against Lightning Impulse Voltages (뇌임펄스전압에 대한 돌침형 피뢰침의 주수섬락특성과 개선 방안)

  • 이복희;강석만;엄주홍;이승칠;김승지
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.93-100
    • /
    • 2002
  • In this paper, in ordor to examine the relevant technical facts which are very instructive to revise the domestic standard for lightning protection systems, standards and technical guideline for the protection of structure against lightning were reviewed, and several issues of the domestic standards were experimentally investigated. As a consequence, the insulator of relatively low implse voltage and a large percentage of lighting rods is flashovered by relatively low impulse voltage and a lage percentage of lighting current flows through supporting mast. Thus the potential gradient in the vicinity of supporter for lighting rods is extremely increased and the role of lighting propection systems is nullified. It seems obvious that the flashover of insular supporting lighting rod can range from erratic operation of microelectronic devices to minor physical ham or even death, or costly damage electrical equipment.

Microstructure and Electrical Properties of ZPCCYT Varistor Ceramics

  • Nahm, Choon-Woo;Lee, Sun-Kwon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.262-265
    • /
    • 2012
  • The Microstructure and nonlinear electrical properties of the ZPCCYT (ZnO-$Pr_6O_{11}$-CoO-$Cr_2O_3$-$Y_2O_3$-$Tb_4O_7$) varistors were investigated for different amounts of $Tb_4O_7$. The addition of $Tb_4O_7$ has a significant effect on microstructure and electrical properties. Analysis of the microstructure indicated that the ceramics consisted of ZnO grain as a main phase and a few secondary phases as a mix of $Pr_6O_{11}$, $Y_2O_3$, and $Tb_4O_7$. As the amount of $Tb_4O_7$ increased, the sintered densities of pellets increased from $\rho$ = 5.70 to $5.78g/cm^3$ and the average grain size decreased from d = 4.8 to $3.6{\mu}m$. The increase in the amount of $Tb_4O_7$ increased from $E_B$ = 7,473 to 10,035 V/cm and from ${\alpha}$ = 39.7 to 52.2. In particular, it was found that the ceramics modified with 1.0 mol% in the amount of $Tb_4O_7$ are suited for the varistors for high voltage in the light of a high sintered density and a high voltage gradient.

An RMRAC Controller for Permanent Magnet Synchronous Motor Based On Modified Current Dynamics (보정된 전류동역학에 기반한 영구자석 전동기의 참조모델 강인적응제어기)

  • Jin, Hong-Zhe;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.10
    • /
    • pp.991-997
    • /
    • 2008
  • A new RMRAC scheme far the PMSM current regulation is proposed in a synchronous frame, which is completely free from the parameter's uncertainty. A current regulator of PMSM is the inner most loop of electromechanical driving systems and plays a foundation role in the control hierarchy. When the PMSM runs in high speed, the cross-coupling terms must be compensated precisely for large system BW. In the proposed RMRAC, the input signal is composed of a calculated voltage defined by MRAC law and an output of the disturbance compensator. The gains of feed forward and feedback controller are estimated by the proposed modified gradient method, where the system disturbances are assumed as filtered current regulation errors. After the compensation of the system disturbance from error information, the corresponding voltage is fed forward to control input to compensate for real disturbances. The proposed method robustly compensates the system disturbance and cross-coupling terms. It also shows a good realtime performance due to the simplicity of control structure. Through real experiments, the efficiency of the proposed method is verified.

A Numerical Algorithm for Fault Location Estimation and Arc Faults Detection for Auto-Reclosure (자동 재폐로기의 동작책무를 위한 아크전압 판정 및 사고거리 표정 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Zheng, Tai-Ying;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1294-1303
    • /
    • 2009
  • This paper presents a new numerical algorithm for fault discrimination and fault location estimation when occur to arcing ground and arcing line to line on transmission lines. The object of this paper is developed from new numerical algorithm to calculate the fault distance and simultaneously to make a distinction between transient and permanent faults. so the first of object for propose algorithm would be distinguish the permanent from the transient faults. This arcing fault discrimination algorithm is used if calculated value of arc voltage amplitude is greater than product of arc voltage gradient and the length of the arc path, which is equal or greater than the flashover length of a suspension insulator string[1-3]. Also, each algorithm is separated from short distance and long distance. This is difference to with/without capacitance between short to long distance. To test the validity of the proposed algorithms, the results of algorithm testing through various computer simulations are given. The test was simulated in EMTP/ATP simulator under a number of scenarios and calculate of algorithm was used to MATLAB.

Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System (분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choe, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF