• Title/Summary/Keyword: Voltage dip

Search Result 51, Processing Time 0.026 seconds

An Acquisition and Analysis Equipment of Dynamic/Static Data on a Rotating Vibration (회전체 진동 데이터의 AC/DC 성분 데이터 획득 및 분석 장치)

  • Lee, Jung Suk;Ryu, Deung Ryeol;Lee, Cheol
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.127-137
    • /
    • 2009
  • This paper is proposed that in-output Digital module is acquired a vibration signal of a rotating machinery by Data Acquisition System. The module is designed to get ride of nose through low pass filter on the vibration signal from sensors and set the gain value for being able to sampling AC to DC, and also the sampled data by sampler and the conversed data by DIP/FPGA is supplied to the analyzer for analysis at a software tool. The DIP(Digital Signal Processor) of the Digital input/output Board makes Average voltage, Peak to Peak voltage, RMS(Root Mean Square) and Gap voltage, also FFT(Fast Fourier Transform) for rotating vibration diagnosis.

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

A Peak Detector for Variable Frequency Three-Phase Sinusoidal Signals (가변주파수 3상 정현파 신호의 최대전압 검출기)

  • 김홍렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.210-215
    • /
    • 1999
  • The proposed detector is consists of three-phase sinusoidal signal generator and peak detector. This peak detector can detect the peak voltage value at the state of variable frequency. In experi-ment three-phase sinusoidal signals are generated from D/A converter using IBM PC and deliv-ered to the peak detector. Each signals are squared by multiplier and summed up Peak value is the square root of summed value extracted by square root circuit.

  • PDF

Fabrications and Properties of Al/$VF_2$/$n^+$-Si(100) Structures by Dip Coating Methode (Dip Coating 법에 의한 Al/$VF_2$-TrFE/Si(100) 구조의 제작 특성)

  • Kim, Ka-Lam;Jeong, Sang-Hyun;Yun, Hyeong-Seon;Lee, Woo-Seok;Kwak, No-Won;Kim, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.20-21
    • /
    • 2008
  • Ferroelectric vinylidene fluoride-trifluoroethylene ($VF_2$-TrFE) copolymer films were directly deposited on degenerated Si ($n^+$, 0.002 $\Omega{\cdot}cm$) using by dip coating method. A 1 ~ 3 wt% diluted solution of purified vinylidene fluoride-trifluoroethylene ($VF_2$:TrFE=70:30) in a dimethylformamide (DMF) solvent were prepared and deposited on silicon wafers using dip coating method for 10 seconds. After Post-Annealing in a vacuum ambient at 100~200 $^{\circ}C$ for 60 min, upper aluminum electrodes were deposited by thermal evaporation through the shadow mask to complete the MFS structure. The ferroelectric $\beta$-phase peak of films, depending on the annealing temperature, started to show up around $125^{\circ}C$, and the intensity of the peak increased with increasing annealing temperature. Above $175^{\circ}C$, the peak started to decrease. The C-V characteristics were measured using a Precision LCR meter (HP 4284A) with frequency of 1MHz and a signal amplitude of 20 mV. The leakage-current versus electric-field characteristics was measured by mean of a pA meter/DC voltage source (HP 4140B).

  • PDF

Electrochemical Characteristics of EDLC Fabricated by Different Preparation Processes of Activated Carbon Electrode (활성탄소 전극의 제조공정에 따른 EDLC의 전기화학적 특성)

  • Yang Chun-Mo;Kim H.J.;Cho W.I.;Cho B.W.;Yun K.S.;Rim Byung-O
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.98-103
    • /
    • 2001
  • The electrochemical characteristics and specific capacitance were investigated by preparation processes (dip coating method, doctor blade coating method and paste rolling method) of activated carbon electrode for an EDLC(electric double layer capacitor). The EDLC using $LiPF_6$ salts and PC-DEC solvents showed good specific capacitance, 130F/g and small IR-drop at linear time-voltage curve. 0.11V, Cyclic voltammetry analysis using the activated carbon electrode prepared by dip coating method was shown closer to ideal EDLC characterization.

Output Control of Wind Farm Side Converter from DC Link for DC Voltage Stabilization with HVDC (해상풍력 연계용 HVDC의 DC전압 안정화를 위한 DC Link의 발전기측 컨버터 제어 전략)

  • Lee, Hyeong-Jin;Kang, Byoung-Wook;Huh, Jae-Sun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1479-1485
    • /
    • 2016
  • This paper presents DC voltage recovery time improvement method in DC link of High Voltage Direct Current (HVDC) with offshore wind farm. The wind farm should be satisfied Low Voltage Ride Through(LVRT) control strategy when grid faults occur. The LVRT control strategy indicates actions which have to be executed according to the voltage dip ratio and the fault duration. However, The LVRT control strategy makes between wind farm and power system through DC Link voltage when grid fault occurs. The de-loading scheme is one of the method to control the DC voltage. But de-loading scheme need to long DC voltage recovery time. Thus, this paper proposes an improved de-loading scheme and we analysis DC voltage and active power reference through a simulation.

A Study of Line-Interactive UPS with Voltage Compensator (Line-Interactive 전압보상기에 관한 연구)

  • Woo Sung-Min;Kang Dae-Wook;Lee Woo-Cheol;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.487-490
    • /
    • 2001
  • Power Quality and Reliability are becoming important issues for critical and sensitive loads. This paper describes the Line Interactive UPS with the function of Voltage Compensator that is 'Line interactive Dynamic Voltage Restorer(LIDVR). The main purpose of a LIDVR is to compensate for voltage sag(dip), outage and overvoltage. The overall system consists of three controller 1) current controller with prediction 2) voltage controller and 3) proposed variable DC LINK controller. The variable DC LINK control technique using the LIDVR protects DC LINK from overflowing the input current. The simulation results are depicted in this paper to show the effect of this proposed system.

  • PDF

NO and $SO_2$ Removal by Dielectric Barrier Discharge-Photocatalysts Hybrid Process (유전체 장벽 방전-광촉매 복합공정에 의한 NO와 $SO_2$ 제거)

  • Kim, Dong-Joo;Nasonova, Anna;Kim, Kyo-Seon
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.115-121
    • /
    • 2007
  • In this study, we analyzed experimently the NO and $SO_2$ removal by the dielectric barrier discharge-photocatalysts hybrid process. The glass spheres were used as a dielectric material for dielectric barrier discharge and the $TiO_2$ photocatalysts were coated onto those spheres by the dip-coating method. The $TiO_2$ particles were coated in the sponge-shape, which has the larger surface area. As the voltage applied to the plasma reactor, the pulse frequency of applied voltage, or the residence time increases, the NO and $SO_2$ removal efficiencies increase. The increase in the supplied concentrations of NO and $SO_2$ leads to the higher energy for NO and $SO_2$ removal and the NO and $SO_2$ removal efficiencies decrease. These experimental results can be used as a basis to design the dielectric barrier discharge-photocatalysts hybrid process to remove NO and $SO_2$.

  • PDF

Sol-gel Coating of ZrO2 Film in Aluminium Etch Pit and Anodizing Properties (알루미늄 에치피트에 ZrO2 막의 졸-겔 코팅 및 양극산화 특성)

  • Chen, Fei;Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.24 no.5
    • /
    • pp.259-265
    • /
    • 2014
  • $ZrO_2$ films were coated on aluminum etching foil by the sol-gel method to apply $ZrO_2$ as a dielectric material in an aluminum(Al) electrolytic capacitor. $ZrO_2$ films annealed above $450^{\circ}C$ appeared to have a tetragonal structure. The withdrawal speed during dip-coating, and the annealing temperature, influenced crack-growth in the films. The $ZrO_2$ films annealed at $500^{\circ}C$ exhibited a dielectric constant of 33 at 1 kHz. Also, uniform $ZrO_2$ tunnels formed in Al etch-pits $1{\mu}m$ in diameter. However, $ZrO_2$ film of 100-200 nm thickness showed the withstanding voltage of 15 V, which was unsuitable for a high-voltage capacitor. In order to improve the withstanding voltage, $ZrO_2$-coated Al etching foils were anodized at 300 V. After being anodized, the $Al_2O_3$ film grew in the directions of both the Al-metal matrix and the $ZrO_2$ film, and the $ZrO_2$-coated Al foil showed a withstanding voltage of 300 V. However, the capacitance of the $ZrO_2$-coated Al foil exhibited only a small increase because the thickness of the $Al_2O_3$ film was 4-5 times thicker than that of $ZrO_2$ film.

Operating Characteristic Analysis of the Induction Generator by the Reactor Starting (리액터 기동 유도발전기의 동작 특성 해석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.138-142
    • /
    • 2014
  • In general, the voltage stability of induction generator is lower than synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used little by little in small hydroelectric power station rather than 1000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the penetration of the induction generator, it is necessary to present a method of reducing inrush current. In this study, we suggested that it is possible to present a reactor startup method, by applying the parameter to reduce the voltage drop.