• 제목/요약/키워드: Voltage Sensitivity

검색결과 651건 처리시간 0.028초

동적 시뮬레이션을 이용한 Voltage Sensitivity 지수 계산 (Voltage Sensitivity Index Calculation using Dynamic Simulation)

  • 정성원;박인덕;이근준;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.453-454
    • /
    • 2007
  • This paper proposes the calculation method of voltage sensitivity index using CBEMA power acceptability curves and the voltage curves of the load bus to which momentary events occur. Voltage sensitivity index is represented by areas between two curves. Voltage sensitivity index is a parameter that depicts the ratio of a load disruption. The correlation between the installation cost of compensation devices and the voltage sag index on the bus can be used the validity of compensation.

  • PDF

전력 계통 정적 전압 안정도 해석법의 동일 근거에 관한 연구 (A Study on the identical basis of static voltage stability analysis methods in power systems)

  • 문영현;김백;이응혁
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.457-466
    • /
    • 1996
  • The Voltage stability problem has recently been dealt with in the literature from various points of view. The diverse theories have been established in voltage stability analysis because of the complicates of power systems and diverse phenomena of voltage collapse. Through rigorous mathematical operations, this paper shows that all the major methods used in static voltage stability, i.e - Jacobian method, voltage sensitivity method, real and reactive power loss sensitivity method and energy function method - have an identical background in theory. The results from the test in sample systems have shown the validity of this verification. (author). refs., figs., tabs.

  • PDF

디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화 (Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis)

  • 김상현
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.541-547
    • /
    • 2018
  • 흉부 디지털 단층합성(chest digital tomosynthesis, CDT) 검사 시 관전압 및 감도(sensitivity) 변화에 의한 선량감소 효과와 정량적 평가로 선량 최적화 조건을 평가하고자 한다. 관전압 125 kV, 135 kV 설정에 따른 sensitivity 200, 320, 400 변화하여 팬텀의 CDT 영상을 획득하였다. 감도와 관전압 변화 따른 선량과 면적선량(DAP)을 평가하였다. 화질평가는 최대신호 대 잡음비(PSNR), 대조도 대 잡음비(CNR), 신호 대 잡음비(SNR)를 image J를 이용하여 분석하였다. 선량은 14~23%, 면적선량은 13~26% 정도 sensitivity 200, 125 kV에 비해 측정치가 낮아졌고, sensitivity 가 높아짐에 따라 감소율 커짐을 알 수 있었다. PSNR은 27dB 이상으로 모두 의미 있는 수치였고, CNR, SNR은 sensitivity가 낮을수록 우수했으나, 항목마다 통계의 유의성은 달랐다. CNR과 SNR 모두 sensitivity 320, 135 kV가 sensitivity 200, 125 kV와 통계적으로 유의하지 않았다(p>0.05). CDT는 감도, 관전압과 디지털 촬영의 장비의 장점인 보정능력을 이용하여 더 작은 선량으로 화질을 유지 시킬 수 있다.

직류 마이크로그리드의 전력 공유 정확도 및 전압 제어 성능 향상을 위한 전압 민감도 행렬 기반의 분산 제어 방법 (A Distributed Control Method based on Voltage Sensitivity Matrix in DC Microgrids for Improvement of Power Sharing Accuracy and Voltage Regulation Performance)

  • 이기영;고병선;이재석;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.345-351
    • /
    • 2018
  • A distributed control method is proposed to improve the power sharing performance of bidirectional distributed generators and the voltage regulation performance of a DC bus in a DC microgrid. Voltage sensitivity analysis based on power flow analysis is conducted to analyze the structural characteristics of a DC microgrid. A distributed control method using a voltage sensitivity matrix is proposed on the basis of this analysis. The proposed method uses information received through the communication system and performs the droop gain variation method and voltage shift method without additional PI controllers. This approach achieves improved power sharing and voltage regulation performance without output transient states. The proposed method is implemented through a laboratory-scaled experimental system consisting of two bidirectional distributed generators, namely, a load and a non-dispatchable distributed generator in a four-bus ring-type model. The experimental results show improved power sharing accuracy and voltage regulation performance.

A Positioning Method of Distributed Power System by Considering Characteristics of Droop Control in a DC Microgrid

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Sang-Il;Kim, Rae-Young;Cho, Jin-Tae;Kim, Ju-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.620-630
    • /
    • 2018
  • In this paper, a positioning method of distributed power system is proposed to minimize the average voltage variation of a DC microgrid through voltage sensitivity analysis. The voltage sensitivity under a droop control depends on the position of the distributed power system. In order to acquire a precise voltage sensitivity under a droop control, we analyzed the power flow by introducing a droop bus with the considerations of the droop characteristics. The results of the positioning method are verified through PSCAD/EMTDC simulation.

A Study on Effective Enhancement of Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost

  • Lee Byung Ha;Kim Jung-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.252-259
    • /
    • 2005
  • Various problems such as increase of power loss and voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of generation cost is derived and it is used for effectively determining the locations of reactive power compensation devices and for enhancing the load power factor appropriately. In addition, voltage variation penalty cost is introduced and integrated costs including voltage variation penalty cost are used for determining the value of load power factor from the point of view of economic investment and voltage regulation. It is shown through application to a large-scale power system that the load power factor can be enhanced effectively using the load power factor sensitivity and the integrated cost.

스트레스 감도 향상을 위한 턴 온 직후의 조름 효과를 이용한 얇은 질화막 폴리실리콘 전계 효과 트랜지스터 압력센서 (A Polysilicon Field Effect Transistor Pressure Sensor of Thin Nitride Membrane Choking Effect of Right After Turn-on for Stress Sensitivity Improvement)

  • 정한영;이정훈
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.114-121
    • /
    • 2014
  • We report a polysilicon active area membrane field effect transistor (PSAFET) pressure sensor for low stress deflection of membrane. The PSAFET was produced in conventional FET semiconductor fabrication and backside wet etching. The PSAFET located at the front side measured pressure change using 300 nm thin-nitride membrane when a membrane was slightly strained by the small deflection of membrane shape from backside with any physical force. The PSAFET showed high sensitivity around threshold voltage, because threshold voltage variation was composed of fractional function form in sensitivity equation of current variation. When gate voltage was biased close to threshold voltage, a fractional function form had infinite value at $V_{tn}$, which increased the current variation of sensitivity. Threshold voltage effect was dominant right after the PSAFET was turned on. Narrow transistor channel established by small current flow was choked because electron could barely cross drain-source electrodes. When gate voltage was far from threshold voltage, threshold voltage effect converged to zero in fractional form of threshold voltage variations and drain current change was mostly determined by mobility changes. As the PSAFET fabrication was compatible with a polysilicon FET in CMOS fabrication, it could be adapted in low pressure sensor and bio molecular sensor.

손실 감도를 이용한 전압붕괴 근접도 지표 (Voltage Collapse Approximity Indeces Using The Loss Sensitivity)

  • 김용배;김건증;추진부;김원겸;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.218-221
    • /
    • 1992
  • Recent years voltage collapse phenomenon have a great attention to power system engineers. As the system size increases the voltage problem shows a very complicated and the reactive power contol problem becomes more difficult. This paper gives an efficient methods for calculating voltage collapse proximity index based on the reactive power loss sensitivity and real power loss sensitivity. The system voltages are tightly associated with the system reactive power, so the proposed voltage collapse proximity index is very usefull for the system voltage control problems. Numerical examples showed a good and reliable results.

  • PDF

실험계획법을 이용한 예인 음탐기용 음향패키지 형상 연구 (A study on configuration of acoustic package for towed array sonar using design of experiments)

  • 이정현;신증호;권오조;김군칠
    • 한국음향학회지
    • /
    • 제38권2호
    • /
    • pp.200-206
    • /
    • 2019
  • 본 연구에서는 예인 음탐기용 음향패키지에 대한 수신전압감도 특성을 분석하기 위해 수치해석과 실험계획법을 적용하였다. 수치해석 결과는 초기 설계된 음향패키지의 구조 공진 모드 특성으로 인한 수신전압감도 변화를 보여준다. 수신전압감도 편차를 줄이기 위해 도출된 음향패키지 설계 변수의 영향은 실험계획법을 통해 분석하였다. 수신전압감도 편차는 수중청음기 쉴드캔 두께(t)의 변화에 가장 민감한 것을 확인하였다. 수조시험 결과 실험계획법에 의해 도출된 음향패키지는 수신전압감도 편차가 감소됨을 확인하였다.

무효전력 손실감도를 이용한 정적 전압 안정도 해석 (Static Voltage Stability Analysis using Reactive Power Loss Sensitivity)

  • 김원겸;이복용;이상철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.52-55
    • /
    • 1999
  • In recent years, much attention has been paid to the voltage collapse phenomena. There has been reported many cases about the voltage collapse in many countries. These voltage collapse phenomena are known as the event that can occur due to reactive power deficits. This paper proposes an efficient method that can pursue the reactive power loss changes and gives the simple voltage collapse proximity indicator(VCPI) based on the reactive power loss sensitivities using optimal techniques. By comparing reactive power loss sensitivity with active power loss sensitivity, it is also proved that VCPI based on reactive power loss sensitivities is more effective. The developed VCPI is derived from the Jacobian matrix of Load Flow and the computational burden is very low and on-line implementation is possible. The proposed method is applied to a IEEE-14 bus test system and reliable and promising results are obtained.

  • PDF