• Title/Summary/Keyword: Voltage Disturbance

Search Result 248, Processing Time 0.024 seconds

외란관측기를 이용한 새로운 데드타임 보상법 (A New Dead-time Compensation Method using Disturbance Observer)

  • 김현수;문형태;김명복;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.252-255
    • /
    • 1999
  • A new dead-time compensation method using a disturbance observer is proposed. The dead-time causes the voltage distortion and it can be considered as the disturbance voltage. In this paper, the disturbance voltage is estimated by minimal order observer in the d-q frame and the estimated disturbance voltage is summed with voltage command by a feed-forward. The experiments are carried out for the DSP-based BLDC motor drive system and the results show the effectiveness of the proposed method.

  • PDF

Dynamics of electric system for electromechanical integrated toroidal drive under mechanical disturbance

  • Hao, Xiuhong;Xu, Lizhong
    • Interaction and multiscale mechanics
    • /
    • 제2권2호
    • /
    • pp.189-207
    • /
    • 2009
  • Dynamics of the electric system for the toroidal drive under mechanical disturbance is presented. Using the method of perturbation, free vibrations of the electric system under mechanical disturbance are studied. The forced responses of the electric system to voltage excitation under mechanical disturbance are also presented. We show that as the time grows, the resonance vibration caused by voltage excitation still exists and the vibrations caused by mechanical disturbance are enlarged. The coupled resonance vibration caused by mechanical disturbance and voltage excitation is discussed. The conditions of the occurrence of coupled resonance are studied.

시간지연 제어기법을 이용한 새로운 데드 타임 보상법 (A New Dead-Time Compenstion Method using Time Delay Control Approach)

  • 김현수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.425-428
    • /
    • 2000
  • A new dead time compensation method using time delay control approach is presented. The dead time in switching pattern cause the voltage distortion and it can be considered as the disturbance voltage. In this paper the disturbance voltage is estimated using time delay control and the estimated disturbance voltage is summed with voltage command in predictive current control by a feed-forward. The proposed scheme is implemented on a PMSM and the effectiveness is verified through comparative simulation.

  • PDF

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

전압 새그 및 스웰 발생 모드에서 부하역률에 따른 전압외란 발생기의 출력전압 변동 해석 (Analysis of Output Voltage Variation of a Voltage Disturbance Generator according to the Load Power Factor in Voltage Sag and Swell Mode)

  • 한흥수;정혜수;정재헌;노의철;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.80-87
    • /
    • 2016
  • This study investigates output voltage variation of a voltage disturbance generator in case of sag and swell modes. The generator uses series transformers and silicon-controlled rectifier thyristors to provide voltage disturbance; consequently, voltage drop at the output terminal is inevitable. On the basis of the analysis, voltage drop increases as the power factor decreases in lagging. Voltage drop is 3.7 [%] at a power factor (lagging) of 0.8. Simulation and experimental results show the validity of the analysis.

함수제어 기법을 이용한 Buck 컨버터 제어 (Control of the Buck Converter using the Function Control Law)

  • 이성백;원영진;김태웅
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.81-89
    • /
    • 1997
  • In order to achieve the zero voltage regulation of the output voltage, the function control law will be used. In the previous function control law, only the proportional controller is used and the stability of the closed loop system was not analyzed. In this paper, for the realization of the control law, a new method to retrieve the low frequency component of the inductor voltage is proposed and analyzed. The large signal closed loop characteristics are alos analyzed to ensure the stable operation of the system disturbances. By using the function control law in the control system, the effect of the disturbance of the supply voltage is reduced in 93.3% for the direct dusty ration method. Also, in the effect of the disturbance of the load current, the output voltage has a logn recovery-time and is changed proportionally in the direct duty ratio method, but has stable in the function control law. Finally, the analysis shows that the disturbance of the output voltage being due to the supply voltage variation can be eliminated completely and the closed loop output voltage is insensitive to the disturbance of the load current. Therefore, it is proved that by using the function control law, the switching power supply with zero-voltage regulation output voltage can be realized.

  • PDF

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어 (A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter)

  • 강대욱;현동석;이우철
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

변압기 기반 3상 전압변동발생기의 전압강하 특성해석 (Analysis of Voltage Drop Characteristics of Transformer-based 3-phase Voltage Disturbance Generator)

  • 한흥수;이영호;송웅협;노의철;김인동;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제15권5호
    • /
    • pp.411-416
    • /
    • 2010
  • 본 논문에서는 변압기 기반 전압변동 발생기의 직렬변압기에 의한 전압강하 특성을 분석하였다. 전압변동 발생기의 회로구성 방식에는 여러 가지가 있으나 본 논문에서는 비교적 비용이 저렴하고 신뢰도가 높은 직렬변압기를 사용한 방식에 대해 다루고자 한다. 직렬변압기에 의한 전압강하는 변압기의 %Z와 부하용량 및 부하역률에 의해 결정된다. 직렬변압기의 설계가 잘못되면 전압강하가 심각하게 발생하여 제대로 된 성능을 확보할 수 없다. 본 논문에서는 10kVA급 전압변동 발생기에 대해 %Z가 4%인 직렬변압기를 사용한 경우 부하역률에 따른 전압강하를 분석하였으며 지상 부하일수록 전압강하가 증가하고 역률이 0.85 지상인 경우 전압강하가 4% 발생함을 시뮬레이션 및 실험을 통하여 확인하였다.

Active Disturbance Rejection Control for Single-Phase PWM Rectifier with Current Decoupling Control

  • Yan, Ruitao;Wang, Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2354-2363
    • /
    • 2018
  • This paper proposed a novel double closed control strategy for single-phase voltage source pulse width modulation (PWM) rectifier based on active disturbance rejection control (ADRC) and dq current decoupling control. First, the mathematical model of the single-phase PWM rectifier in the d-q axis synchronous rotating reference frame is established by constructing a virtual component using a second-order generalized integrator (SOGI). Then, the mathematical model is simplified according to the active power conservation, and the first-order equation of single-phase PWM rectifier voltage outer loop is acquired. A linear auto-disturbance rejection controller is used to design the voltage outer loop according to the first-order equation. Finally, the proposed control strategy and the traditional PI control are compared and verified by simulation and physical experiments. Both simulation and experimental results confirm that the proposed control strategy has excellent dynamic performance and strong rejection ability to disturbances.