• Title/Summary/Keyword: Volatile organic compounds (VOCs)

Search Result 686, Processing Time 0.029 seconds

Mechanical Performance Evaluation in Concrete Impregnated with Silicate for TiO2 Utilization (광촉매 활용을 위한 실리케이트 기반 표면 침투제를 적용한 콘크리트의 역학적 성능 평가)

  • Kim, Hyeok-Jung;Kim, Young-Kee;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.108-114
    • /
    • 2018
  • Degradations of durability and aesthetic performance in concrete happen during service life due to surface deterioration and dirt stains. Recently, many researches have been performed on self-cleaning and surface enhancement through surface impregnant using photocatalytic reaction with VOCs(Volatile Organic Compounds) removal. This paper is for preliminary study on surface impregnation with silicate and photocatalysis - $TiO_2$. For the work, two types of silicate based impregnants(CS - Coloidal Silica and SC - Sodium Alumina Silicate) are considered. Several tests for viscosity and surface tension are performed, and pull-off test on impregnated concrete is performed. For the surface impregnated concrete, $TiO_2$ is absorbed through submerging and spraying conditions. Through compressive strength test and SEM analysis, it is evaluated that spraying $TiO_2$ on surface impregnated concrete after 30min. of drying period is very effective both for strength enhancement and surface densification.

Adsorption/Desorption Properties of ACF on Toluene and MEK with Operation Condition (공정 조건에 따른 톨루엔 및 MEK에 대한 ACF의 흡·탈착 특성)

  • Baek, Geun-Ho;Kim, Jung-Su;Jang, Hyun-Tae;Cha, Wang-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2898-2903
    • /
    • 2011
  • Adsorption/desorption characteristics of low concentration methylethylketone(MEK) and toluene vapors in beds packed with activated carbon fibers(ACF) was investigated. Performance of ACF adsorption was characterized by the equilibrium capacity, time to reach equilibrium and desorption efficiency. Experiments were carried out to define the effect of operation variables, such as feed concentration, flow rate, moisture content and bed height. The breakthrough time was shorten with the increase of temperature, flow rate and feed concentration. In addition, an increase of packed height of adsorbents lengthen the breakthrough time. The ACF loaded with MEK and toluene was satisfactorily regenerated by programed heating. It is observed that MEK is more easily removed than toluene at below temperature of $150^{\circ}C$.

Characterization of Atmospheric Concentrations of Volatile Organic Compounds in Industrial Areas of Pohang and Gumi Cities (포항과 구미의 대규모 산단지역 대기 중 휘발성 유기화합물 농도 분포 특성에 관한 연구)

  • Baek Sung-Ok;Kim Soo-Hyun;Kim Mi-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.2 s.49
    • /
    • pp.167-178
    • /
    • 2005
  • This study was carried out to evaluate the temporal, spatial, and seasonal variations of VOC, and to characterize the VOC concentrations in two large industrial complexes located in Pohang and Gumi cities. Twenty -four hours continuous sampling of selected VOC was made with STS 25 sequential tube samplers and double-bed adsorbent tubes. Air samples were collected every three hour interval for 7 consecutive days in each site during summer and winter. VOC were determined by thermal desorption coupled with GC/MS. A total of 27 VOCs of environmental concern were determined, including aliphatic, aromatic and halides. Generally. concentrations of toxic VOC were higher in Gumi than Pohang, and VOC levels in industrial areas were typically several-fold higher than those in residential areas. The most abundant VOC appeared to be toluene for both cities. However, chlorinated VOC were higher in Gumi than Pohang, while aromatic VOC were more abundant in Pohang than in Gumi. Two cities showed relatively different variations of VOC concentrations within a day. It is likely that traffic related sources are major factors affecting the VOC in Pohang, and industrial solvents usages are important sources in Gumi. These results imply that the occurrence and levels of atmospheric VOC are strongly dependent on the type of industries in each city. Therefore, in order to develop any control strategies or to establish the priority rankings for VOC in large industrial complexes, the type of industries and the occurrence of VOC in the atmosphere should be taken into consideration.

Expression pattern of floral scent genes in different flowering stages of Chrysanthemum cultivars

  • Mekapogu, Maniulatha;Ahn, Myung Suk;Yoo, Jong Hee;Jeong, Jae Ah;Park, Jong Taek;Kwon, Oh Keun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.114-114
    • /
    • 2018
  • Among the various volatile organic compounds (VOCs) emitted by the plant, floral scent plays a key role in attracting pollinators for reproduction and mediates ecological interactions. Floral scent is an important trait and industry drives the competition for flowers with novel scents. Chrysanthemum is one of the well-known ornamental plants and is a popular cut flower across the world. Floral scent and the genes responsible for the floral scent emission are poorly studied in chrysanthemum. In the present study, floral scent and the expression pattern of floral scent genes were analyzed in two chrysanthemum cultivars 'Golden Egg' and 'Gaya Glory'. Initially, intensity of the floral scent in five developing stages of flower including 'budding (B), bud developing (BD), initial blooming (IB), almost open (AO) and open flower (OF)' was analyzed using electronic nose (E-nose) with six metal oxide sensors. Based on the distance analysis, different stages of flower showed different relative intensity of scent according to the sensory evaluation. Although the scent pattern differed by stage, scent intensity was strongest in the OF stage in the completely opened flower in both the cultivars. Further, expression pattern of six genes in the floral scent pathway including FDS, IDI, ISPH, TPS2, TPS5 and TPS6 was observed in all the five stages of the flower in both the cultivars. The expression pattern of all the six genes differed by stage and the terpene synthase genes TPS2, TPS5 and TPS6 showed good expression levels in the $5^{th}$ flower stage compared to other stages. This study provides a preliminary data for understanding the regulation of floral scent in chrysanthemum.

  • PDF

Characteristics of Volatile Organic Compounds (VOCs) Concentration by Type of Urban Green Space - focused on Dongdaemun-gu, Seoul, Korea - (도시녹지 유형에 따른 휘발성유기화합물 농도 특성 - 서울시 동대문구를 중심으로 -)

  • Jo, Yeseul;Park, Sujin;Roh, Gwan Pyeong
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.330-339
    • /
    • 2018
  • Objectives: The occurrence characteristics of BTEXS and phytoncides were investigated by type of urban forest. Methods: Four types of urban green space (Hongneung Forest, Mt. Chunjang, residential park, and traffic island) and Gwangneung Forest were selected. Monitoring of phytoncides and BTEXS was conducted considering the activity times of urban residents (five times per day) using a Tenax TA tube and suction pump in June 2017 (one day). Results: Phytoncide concentrations were ranked as Gwangneung Forest>Hongneung Forest>Mt. Cheonjang>traffic island>residential park. Relatively high concentrations of phytoncides were also identified in the urban forest. There was no significant difference between Gwangneung Forest and the urban forest. BTEXS concentrations were ranked as traffic island>residential park>Hongneung Forest>Gwangneung Forest>Mt. Cheonjang. Traffic island and residential park showed high levels of BTEXS depending on the inflow of vehicles. The difference in concentration by time was significant for the traffic island in particular. Pollutant levels in Hongneung Forest were as low as in Gwangneung Forest. Conclusion: The concentrations of phytoncides and BTEXS were different by types of urban green space, and the potential for health and hygiene of urban forests were able to be investigated. This study is expected to provide as basic data for the creation of urban forest spaces in the future.

Adsorption Characteristics of Toluene Vapor in Fixed-bed Activated Carbon Column (고정층 활성탄 흡착반응기에서 기상 톨루엔의 흡착특성)

  • Lim Jin-Kwan;Lee Song-Woo;Kam Sang-Kyu;Lee Dong-Whan;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • Adsorption characteristics of toluene vapor, which is one of important source of volatile organic compounds (VOCs), by activated carbon were investigated using a fixed bed adsorption column. The operating parameters such as breakthrough curve, adsorption capacity, mass transfer zone (MTZ), and length of unused bed (LUB) were studied. The experimental results showed that the breakthrough time decreased with increasing inlet toluene concentration and gas flow rate. MTZ and LUB increased with the increase of inlet concentration, gas flow rate, and particle size of activated carbon. The adsorption capacity increased with the increase of inlet toluene concentration, while it decreased with increasing particle size. However, it was kept at constant value regardless of the increase of gas flow rate. Adsorption isotherm of toluene vapor could be represented by the Freundlich adsorption equation fairly well. From the adsorption experiments using some VOC gases such as toluene, xylene, butyl acetate. butanol and acetone, it was also found that the adsorption capacity was higher in the case of gas with higher boiling point and lower vapor pressure.

A Study of Environment Monitoring System based on Sensor Network (센서 네트워크를 이용한 실내 공기질 관리 및 제어에 관한 연구)

  • Kim, Ki-Tae;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.389-392
    • /
    • 2010
  • The problem for the air pollution in the office or the indoor except a specific working area is the continuously issue since the human beings have lived in the dwelling facilities. Measures for that problem are urgently needed. It's possible to solve for the freshair of outside with enough ventilation but that is the awkward situation to be managed by person. It's feasible to supervison and control easily if you use to sensor network under the network. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study compose a IAQM(Indoor Air Quality Management) under the network, suggest the application of supervision and control.

  • PDF

A Study of Environment Monitoring System based on USN (유비쿼터스 센서 네트워크 기반 환경 모니터링 시스템에 관한 연구)

  • Choi, Sam-Gil;Kim, Ki-Tael;Kim, Dong-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1488-1492
    • /
    • 2010
  • USN(Ubiquitous Sensor Network) is the network that widely applies for life of human being. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study realize a IAQM(Indoor Air Quility Management) sensing mechanism composition under the network and suggest the application of Environment monitoring system outlook to measure an Environment element.

The Field Survey of Indoor Environment of the Office Building (오피스 건물의 실내 환경 실태 조사)

  • Yang, Young Kwon;Kang, In Sung;Chung, Min Hee;Moon, Jin Woo;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

Ecotoxicological effects of ballast water effluent teated by an electrolytic method on marine environment

  • Kim, Tae Won;Kim, Keun-Yong;Shon, Myung-Baek;Kim, Young-Soo;Lee, Ji Hyun;Moon, Chang Ho;Son, Min Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.1010-1020
    • /
    • 2014
  • Ballast water effluent treated by an electrolytic method contains reactive chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on marine environment. WET testing was carried out for three marine pelagic organisms, i.e., diatom Skeletonema costatum, rotifer Brachionus plicatilis and fish Paralichthys olivaceus. The biological toxicity test revealed that S. costatum was the only organism that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50% (EC50) values of 12.5%, 25.0% and 83.3%, respectively, at brackish water condition. In contrast, it showed insignificant toxicity at seawater condition. B. plicatilis and P. olivaceus also showed no toxicities to the effluent at the both salinity conditions. Meanwhile, chemical analysis revealed that the ballast water effluent contained total residual oxidants (TROs) below $0.03{\mu}g/L$ and a total of 20 DBPs including bromate, volatile halogenated organic compounds (VOCs), halogenated acetonitriles (HANs), halogenated acetic acids (HAAs) and chloropicrin. Based on ERA, the 20 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. Except monobromoacetic acid, the ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the other 19 DBPs did not exceed 1. Thus, our results of WET testing and ERA indicated that the ballast water effluent treated by electrolysis and subsequently neutralization was considered to have no adverse impacts on marine environment.