• Title/Summary/Keyword: Visual shade selection

Search Result 9, Processing Time 0.021 seconds

THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY (수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가)

  • Kim Lee-Kyoung;Cho In-Ho;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns (자연치와 도재관에 대한 색조선택의 동일성)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

Comparison of different digital shade selection methodologies in terms of accuracy

  • Nursen Sahin;Cagri Ural
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.38-47
    • /
    • 2024
  • PURPOSE. This study aims to evaluate the accuracy of different shade selection techniques and determine the matching success of crown restorations fabricated using digital shade selection techniques. MATERIALS AND METHODS. Teeth numbers 11 and 21 were prepared on a typodont model. For the #11 tooth, six different crowns were fabricated with randomly selected colors and set as the target crowns. The following four test groups were established: Group C, where the visual shade selection was performed using the Vita 3D Master Shade Guide and the group served as the control; Group Ph, where the shade selection was performed under the guidance of dental photography; Group S, where the shade selection was performed by measuring the target tooth color using a spectrophotometer; and Group I, where the shade selection was performed by scanning the test specimens and target crowns using an intraoral scanner. Based on the test groups, 24 crowns were fabricated using different shade selection techniques. The ΔE values were calculated according to the CIEDE2000 (2:1:1) formula. The collected data were analyzed by means of a one-way analysis of variance. RESULTS. For the four test groups (Groups C, Ph, S, and I), the following mean ΔE values were obtained: 2.74, 3.62, 2.13, and 3.5, respectively. No significant differences were found among the test groups. CONCLUSION. Although there was no statistically significant difference among the shade selection techniques, Group S had relatively lower ΔE values. Moreover, according to the test results, the spectrophotometer shade selection technique may provide more successful clinical results.

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

SHADE ANALYSIS OF ANTERIOR TEETH USING DIGITAL SHADE ANALYSIS SYSTEM (Digital Shade Analysis System을 이용한 전치부의 색조 특성에 관한 연구)

  • Kim Hee-Eun;Cho In-Ho;Lim Ju-Hwan;Lim Hun-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.565-581
    • /
    • 2003
  • Statement of problem : A scientific examination and understanding of overall aspects of the natural dentition is the first step involved in making a satisfactory selection in the shade of an aesthetic prosthesis. Proper natural shade selection of the prosthetic restoration that is in harmony with the remaining dentition is as important aesthetically, as harmony of form and function in the anterior dentition. Clinically, the most commonly applied method of shade selection has been visual, but because of the subjective nature inherent to this method, shade selection results are variable and can be influenced by such factors as the technician, the type of shade guide used, and the type and intensity of the lighting. Purpose : The purpose of this study was to develop a more objective and scientific approach to examining and understanding the shade of teeth, which has in turn lead to the development of a number of shade analysis devices that present a more objective method of shade analysis. Material and Method : In this study, the shades of healthy anterior teeth were examined and analyzed using the recently developed digital shade analysis of the $ShadeScan^{TM}$ System. The study examined 80 individuals in their twenties, 40 males and 40 females, presenting 6 healthy, unrestored maxillary anterior teeth. Tooth brushing and oral prophylaxis were performed prior to evaluation. The ShadeScan handpiece was used to acquire images of the 6 maxillary anterior teeth. These images were analyzed using the Vita/Classical mode of the $ShadeScan^{TM}$ Software, and shade maps of each tooth were acquired and divided into cervical, middle, and incisal thirds. The shade distribution of each third, left and right symmetry, and gender differences were investigated and analyzed. Results : The results of the study are as follows : 1. An overwhelming majority of the examined teeth were found to possess shades belong to Group A, with the greatest variations occurring at the middle and cervical thirds of the maxillary central and lateral incisors, in both male and female subjects. 2. Canines of both male and female subjects showed left and right symmetry with uniform shade distribution of A4 and C4, while the lateral and central incisors showed left-right symmetry of the incisal 1/3 with a uniform shade distribution of A2 and A3 shades 3. No significant differences in shade distribution were seen between genders in maxillary canines, whereas maxillary central and lateral incisors showed differences at the middle and cervical thirds between male and female subjects The results of this study show that with the exception of maxillary canines, maxillary anterior teeth display a diverse shade distribution as well as gender differences. Conclusion : Clinically, when making a shade selection using the existing shade guide, one must consider the fact that even a single tooth consists of a variety of shades. The results of this study show that when selecting a shade from a number of groups is difficult, shades from A group are the most consistent with the natural shade or maxillary anterior teeth.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

Comparison of Shade Changes According to Dry/Wet Condition of Tooth using Intra-Oral Colorimeter (건조정도에 따른 자연치아의 색조비교)

  • Choi, Mee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.265-271
    • /
    • 2010
  • One of the most important aspect of esthetic dentistry is shade selection. Alterations to perception of color can occur as a result of numerous factors, including light source, tooth surface texture, observer's ability, surrounding colors, the angle of observation, light and dark adaptation and others. During the clinical procedures, tooth might be in dry or semi-dry condition. The purpose of this study was to compare the shade changes in wet and dry conditions of natural tooth. Groups of measurement are an initial wet condition as control, dry in 10seconds, 1 minute, 5minutes and 30seconds air dry. Using Shadeeye, color difference(${\Delta}E$) between measurements were analyzed and there were significant differences between groups. But most of the differneces were <3.7 ${\Delta}E$ unit. Such differences are below the threshold for perceivable color mismathces in intraoral condition. Shade selection with an intraoral colorimeter could be changes in dry and wet condition but there might be no significant differences in visual color mathing.