• Title/Summary/Keyword: Visual range

Search Result 1,345, Processing Time 0.036 seconds

Clinical Results of Surgical Treatment with Minimally Invasive Percutaneous Plate Osteosynthesis for Displaced Intra-articular Fractures of Calcaneus (최소침습적 금속판 내고정술을 이용한 전위된 관절 내 종골 골절의 임상적 치료결과)

  • Suh, Jae Wan;Yang, Jong Heon;Park, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • Purpose: This study evaluated the clinical results of surgical treatment with minimally invasive plate osteosynthesis for treating displaced intra-articular fractures of the calcaneus in comparison with conventional lateral extensile approach plate osteosynthesis. Materials and Methods: Of 79 cases of Sanders type II or III calcaneus fractures, 15 cases treated with the minimally invasive calcaneal plate (group M) and 64 cases treated with lateral extensile approach calcaneal plate (group E) were identified. After successful propensity score matching considering age, sex, diabetes mellitus history, and Sanders type (1:3 ratio), 15 cases (group M) and 45 cases (group E) were matched and the demographic, radiologic, and clinical outcomes were compared between the two groups. Results: The median time of surgery from injury was 2.0 days in group M and 6.0 days in group E (p=0.014). At the six months follow-up, group M showed results comparable with those of group E in radiographic outcomes. In the clinical outcomes, group M showed better postoperative American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores than did group E (p=0.001, p=0.008). A greater range of subtalar motion was achieved at the six months follow-up in group M (inversion 20.0° vs. 10.0°, p=0.002; eversion 10.0° vs. 5.0°, p=0.025). Although there were no significant differences in complications between the two groups (1 [6.7%] vs. 7 [15.6%], group M vs. group E; p=0.661), there was only one sural nerve injury and no wound dehiscence and deep infection in group M. Conclusion: Minimally invasive plate osteosynthesis showed superior clinical outcomes compared with that of the conventional lateral extensile approach plate osteosynthesis in Sanders type II or III calcaneus fractures. We suggest applying minimally invasive plate osteosynthesis in Sanders type II or III calcaneus fractures.

Surgical Outcome of Cervical Arthroplasty Using $Bryan^{(R)}$

  • Kim, Hong-Ki;Kim, Myung-Hyun;Cho, Do-Sang;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.532-537
    • /
    • 2009
  • Objective : Recently, motion preservation has come to the forefront of emerging technologies in spine surgery. This is the important background information of the emergence of cervical arthroplasty as an alternative to arthrodesis that offers the promise of restoring normal spinal movement and reduces a kinematic strain on adjacent segments. The study was designed to evaluate early surgical outcome and radiological effects of $Bryan^{(R)}$ cervical disc prosthesis. Methods : The authors retrospectively reviewed radiographic and clinical outcomes in 52 patients who received the $Bryan^{(R)}$ Cervical Disc prosthesis, for whom follow-up data were available. Static and dynamic radiographs were measured by computer to determine the angles formed by the endplates of the natural disc preoperatively, those formed by the shells of the implanted prosthesis, the angle of functional spine unit (FSU), and the C2-7 Cobb angle. The range of motion (ROM) was also determined radiographically, whereas clinical outcomes were assessed using Odom's criteria, visual analogue pain scale (VAS) and neck disability index (NDI). Results : A total of 71 $Bryan^{(R)}$ disc were placed in 52 patients. A single-level procedure was performed in 36 patients, a two-level procedure in 13 patients, and a three-level procedure in 3. Radiographic and clinical assessments were made preoperatively. Mean follow-up duration was 29.2 months, ranging from 6 to 36 months. All of the patients were satisfied with the surgical results by Odom's criteria, and showed significant improvement by VAS and NDI score (p < 0.05). The postoperative ROM of the implanted level was preserved without significant difference from preoperative ROM of the operated level (p < 0.05). 97% of patients with a preoperative lordotic sagittal orientation of the FSU were able to maintain lordosis. The overall sagittal alignment of the cervical spine was preserved in 88.5% of cases at the final follow up. Interestingly, preoperatively kyphotic FSU resulted in lordotic FSU in 70% of patients during the late follow up, and preoperatively kyphotic overall cervical alignment resulted in lordosis in 66.6% of the patients postoperatively. Conclusion : Arthroplasty using the $Bryan^{(R)}$ disc seemed to be safe and provided encouraging clinical and radiologic outcome in our study. Although the early results are promising, this is a relatively new approach, therefore long-term follow up studies are required to prove its efficacy and its ability to prevent adjacent segment disease.

A Study On Context Sensitive Highway Design Based On Improved Operating Speed Prediction Methods in National Roads (환경 친화적 도로 설계를 위한 기초 연구 (노선대 지형 및 지역 요소를 고려한 일반국도 주행속도 예측 모형))

  • Kim, Sang-Youp;Choi, Jai-Sung
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.17-33
    • /
    • 2005
  • Highway design speed is a very important design element which determines highway design level. When determining highway design speed, one would estimate it utilizing the most likelihood of design speed and vehicle operating speed relationship. Existing operating speed prediction models only include highway geometric characteristics and their impacts on speed, which usually can not consider the impact of highway design speed on surrounding roadway environment and land use pattern. If this happens, excessive highway construction cost and huge environmental impact can occur. In this research project, a new vehicle operating speed prediction model was developed which can reflect the effect of surrounding roadway environment into vehicle speed prediction. The followings are the research findings : Firstly, highway terrain types and land use pattern on national roads were classified and integrated into drivers' visual recognition pattern. This was performed using a data management software. Secondly, the developed highway terrain types and land use pattern were related to vehicle speeds and it was found that there were significant statistical differences among vehicle speed for each different terrain and land use pattern. Thirdly. the General Linear Model analysis was employed to analyze the effects of highway geometric features, terrain types, and land use patterns. For two-lane highway and four-lane highway tested in this research project, it was found that R squares were 0.67 and 0.85, respectively. Additionally an optimal highway design speed range table, based on this research project. was proposed for practical use. This table can be reliably used on South Korean national road design, but discretion is required for applying this table to other types of highways including provincial roads and municipal roads.

Study on the Development of Program for Measuring Preference of Portrait based on Sensibility (감성기반 인물사진 선호도 측정 프로그램 개발 연구)

  • Lee, Chang-Seop;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • This study aimed to develop a model of the program for automation measuring the preference of the portraits based on the relationship between the image quality factors and the preferences in the portraits for manufacturers aiming at high utilization of the users. in order to proceed with the evaluation, the image quality measurement was divided into objective and subjective items, and the evaluation was done through image processing and statistical methods. the image quality measurement items can be divided into objective evaluation items and subjective evaluation items. RSC Contrast, Dynamic Range and Noise were selected for the objective evaluation items, and the numerical values were statistically analyzed and evaluated through the program. Exposure, Color Tone, composition of person, position of person, and out of focus were selected for subjective evaluation items and evaluated by image processing method. By applying objective and subjective assessment items, the results were very accurate, with the results obtained by the developed program and the results of the actual visual inspection. but since the currently developed program can be evalua ted only after facial recognition of the person, future research will need to develop a program that can evaluate all kinds of portraits.

Preference and Readability of Hangul Fonts in the Presbyopic Age (노안 연령에서 한글서체의 선호도와 가독성 평가)

  • Jeung, Shinhae;Son, Jeong-Sik;Hwang, Hae-Young;Kim, Seong Kun;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.149-156
    • /
    • 2013
  • Purpose: The aim of this study was to determine a suitable type and size of Hangul fonts for printed materials in the presbyopic age. Methods: Based on the most common Hangul fonts used today, three types of fonts were used Hamchrombatang, Sinmoonmyungjo and Sinmyungjo at small font sizes in the range 9-11 point (pt). Subjects were 101 volunteers aged 41 through 85 years. Near visual acuity (VA) was corrected to read VA 0.5 at 40 cm after distance correction. The subjects were asked to read words containing 88 characters in 10 pt after a question about preference. Readability was assessed by reading rate that was calculated as the number of words read correctly in one minute (words per minute, wpm). Results: The most preferred font type was Simmyungjo at small font sizes. Although preferred font sizes were different in each font type, Sinmyungjo was generally preferred at 10 pt more than other fonts. Hamchrombatang and Sinmyungjo were read significantly faster than Sinmoonmyungjo. There was a weak negative relationship between readability and age in Sinmyungjo. In comparing between the top 10% and the bottom 10% group sorted by reading rate, the top group showed lower average age and addition than the bottom group, however there were no significant differences in reading rate among the fonts. Conclusions: Although increasing age tends to be low in readability for Sinmyungjo, in the light of preferred font and readability, it is recommended to use a 10 pt Sinmyungjo font in printed materials for the presbyopic age.

A Research regarding the Figuration Comparison of 3D Printing using the Radiation DICOM Images (방사선 DICOM 영상을 이용한 3차원 프린팅 출력물의 형상 비교에 관한 연구)

  • Kim, Hyeong-Gyun;Choi, Jun-Gu;Kim, Gha-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.558-565
    • /
    • 2016
  • Recent 3D printing technology has been grafting onto various medical practices. In light of this trend, this research is intended to examine the figuration surface's accuracy of 3D images made by using DICOM images after printing by 3D printing. The medical images were obtained from animal bone objects, while the objects were printed after undergoing STL file conversion for 3D printing purposes. Ultimately, after the 3D figuration, which was obtained by the original animal bones and 3D printing, was scanned by 3D scanner, 3D modeling was merged each other and the differences were compared. The result analysis was conducted by visual figuration comparison, color comparison of modeling's scale value, and numerical figuration comparison. The shape surface was not visually distinguished; the numerical figuration comparison was made from the values measured from the four different points on the X, Y and Z coordinates. The shape surface of the merged modeling was smaller than the original object (the animal bone) by average of -0.49 mm in the 3D printed figuration. However, not all of the shape surface was uniformly reduced in size and the differences was within range of -0.83 mm on the experiment.

Electromyography Triggered Training System for Wrist Rehabilitation (근전도 트리거 손목 재활 훈련 시스템 개발)

  • Kim, Younghoon;Le, DuyKhoa;Chee, Youngjoon;Ahn, Kyoungkwan;Hwang, Changho
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.148-155
    • /
    • 2013
  • This study is about the development of the wrist rehabilitation system for the patient who has limited capability of movement after stroke. Electromyography triggered training system (ETTS) can play the role between complete passive training and patient activating training system. Surface EMG was measured on pronator teres muscle and biceps brachii muscle for wrist pronation and supination. Our system detects whether the subject makes muscular effort for pronation or supination or nothing in every 50 ms. When the effort level exceeds the preset percentage of maximal voluntary contraction, the motor rotates according to the direction of the intention of the subject. EMG triggers the motor rotation for the wrist rehabilitation training until the preset angle. To evaluate its performance, the maximum voluntary contraction level was measured for 4 subjects at first. With the audio-visual instruction to rotate the wrist (pronation or supination) the subjects made effort to follow the instruction. After calculating root mean square (RMS) for 50 ms, the controller determines whether there was muscular effort to rotate while holding the motor. When there was an effort to rotate, the controller rotates the motor 0.8 degree. By comparing the RMS values from two channels of EMG, the controller determines the rotational direction. The onset delay is $0.76{\pm}0.24$ s and offset delay is $0.65{\pm}0.22$ s for pronation. For supination the onset delay is $1.24{\pm}0.41$ s and offset delay is $0.77{\pm}0.22$ s. The system responded fast enough to be used for rehabilitation training. The controller perceived the direction of rotation 100% correctly for the pronation and 97.5% correctly for supination. ETTS was developed and the fundamental functions were validated for normal subjects. The clinical validation should be done with patients for real world application. With ETTS, the subjects can train voluntarily over the limitation of the range of motion which increases the effectiveness of the rehabilitation training.

A Study on the Color Conversion Application of Digital Image in Proof Printer Device (교정 인쇄 장치에서 디지털 이미지의 색변환 적용에 관한 연구)

  • Kim, Joeng-Eun;Cho, Ga-Ram;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.27 no.1
    • /
    • pp.29-47
    • /
    • 2009
  • Generally, if RGB image is sent to the printer when we print a digital photograph, the printer will convert RGB to CMYK by the inner built-in drive. Because the difference between color domain of RGB and CMYK will cause that change and difference. The most common way to solve the problem is to convert colors by using ICC profile at RIP software or to adapt automatic color converting from the software of the original printer. So we intended to study show which way is most efficient to the digital output and which color mode device is the best based on the printer's own drive in this paper. we tried to observe and check the extended range of color space such as AdobeRGB as well as CMYK and sRGB. Then we made sure which is the suitable color space. Besides, When we convert RGB mode into CMYK mode by utilizing RIP software and adapt the printer's ICC profile made by our selves, we evaluated the output we get and compared the result with extended RGB image. The results are as follows. In case of RGB mode, the printer requests RGB, and that makes the color space more efficient than CMYK's. Converted to CMYK by utilizing RIP software, the chroma is more linearized than the one produced with its' own driver. Compared with sRGB mode's color gamut, AdobeRGB mode's color gamut and CMYK mode's color, CMYK mode's color gamut is the smallest among 3 of them. CMYK mode's color gamut by utilizing RIP software can be changeable. that can be small and narrow or wide and broad. In other words, the volume of color gamut depends on how CMYK is linearized. The color space of sRGB is more advantageous than the one of AdobeRGB in color-reproduction printed. But in the group $-b^*$, the chroma leaves behind in terms of reproduction, In the group of $-a^*$, the chroma is excellent relatively. Visual evaluation of the image, AdobeRGB image has not many reproduction colors. Specially, according to printers' characteristics, Group B of AdobeRGB and sRGB color space is a long way behind In terms of reproduction but Group Y is excellent relatively.

  • PDF

Correlation between Anterior and Posterior Corneal Astigmatism in Total Corneal Astigmatism (전체 각막난시에서 전면과 후면 각막난시의 상관성)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.377-382
    • /
    • 2014
  • Purpose: To investigate the effect of anterior, posterior corneal astigmatism and total corneal astigmatism on posterior corneal astigmatism by analyzing correlation. Methods: Participants were 31 patients (31 eyes) without corneal disease at the age range of 22 to 28 who had visited hospital to receive corneal refractive surgery. The total corneal astigmatism and anterior and posterior corneal astigmatism were measured using a rotating scheimpflug camera before surgery. The magnitude of astigmatism was calculated with the difference between the meridian of the steep refractive power and the flat, and With-The-Rule and inverse astigmatism were divided according to the direction of the meridian that was the steepest. Results: The averages of total corneal astigmatism and anterior and posterior astigmatism were found to be $1.13{\pm}0.76D$, $1.51{\pm}0.84D$, and $-0.59{\pm}0.17D$. The magnitude of posterior corneal astigmatism was distributed between -1.0 D and -0.25 D in all the subjects, and when the magnitude of total corneal astigmatism was set as 100, the magnitude of anterior corneal astigmatism was $142.9{\pm}29.9%$. Total corneal astigmatism indicated the highest correlation with the magnitude of anterior astigmatism (y = 0.871x-0.184, $R^2=0.982$) and high negative correlation with posterior astigmatism (y = -2.974x-0.184, $R^2=0.698$). All the subjects' anterior and posterior corneal astigmatism was classified into With-The-Rule. Conclusions: Anterior and posterior corneal astigmatism in the subjects in their 20's showed the magnitude of -3.8 D in 0.2 D and -0.25 D in -1.0 D separately, and both anterior and posterior astigmatism indicated a high percentage of With-The-Rule.

Reusable Multi-story 3D Animation (재구성이 가능한 멀티스토리 3D 애니메이션)

  • Kim, Sungrae;Kim, Ho Sung;Tak, Ji-young;Park, Ji-en;Lim, Sun-hyuk;Kim, Soosanna;Lee, Kyu-seon;Lee, Ji-hyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.238-242
    • /
    • 2007
  • The existent UCC sites display only finalized contents by publisher. It dose not provide any platform for resources of UCC that public users could reorganize. This paper has developed a platform to be able to produce reusable content using the scenes of the contents and produced a 3D animation with multiple story. It is necessary for user to search the provided contents for easy reorganization of the contents. The scene is classified by the description and information of the scene for handy search. It is obscure for a movie clip to be represent with only one word. Therefore, the proposed platform provides the search technique with a overlapping choice for the specific categories that include most of elements for the scene. Then the user can choose a specific range of the selected movie clip, make a new story with reorganizing the order, and put a caption or BGM on the movie clip. The complete movie clip has the search preferences as a category, new clips, and top favorites. With the Multi-Story line concept, we made a 3D animation about episodes of thermal dolls in the Doll World. This attempt will come to the new marketing way for a field of the visual media like as Music Video, Drama, Feature Film, Commercial Film.

  • PDF