• Title/Summary/Keyword: Visual occlusion

Search Result 95, Processing Time 0.025 seconds

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

Comparison of Shade Changes According to Dry/Wet Condition of Tooth using Intra-Oral Colorimeter (건조정도에 따른 자연치아의 색조비교)

  • Choi, Mee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.265-271
    • /
    • 2010
  • One of the most important aspect of esthetic dentistry is shade selection. Alterations to perception of color can occur as a result of numerous factors, including light source, tooth surface texture, observer's ability, surrounding colors, the angle of observation, light and dark adaptation and others. During the clinical procedures, tooth might be in dry or semi-dry condition. The purpose of this study was to compare the shade changes in wet and dry conditions of natural tooth. Groups of measurement are an initial wet condition as control, dry in 10seconds, 1 minute, 5minutes and 30seconds air dry. Using Shadeeye, color difference(${\Delta}E$) between measurements were analyzed and there were significant differences between groups. But most of the differneces were <3.7 ${\Delta}E$ unit. Such differences are below the threshold for perceivable color mismathces in intraoral condition. Shade selection with an intraoral colorimeter could be changes in dry and wet condition but there might be no significant differences in visual color mathing.

Speech Stimuli on the Diagnostic Evaluation of Speech with Cleft Lip and Palate : Clinical Use and Literature Review (구개열 환자 말 평가 시 검사어에 대한 고찰 : 임상현장의 말 평가 어음자료와 문헌적 고찰을 중심으로)

  • Choi, Seong-Hee;Choi, Jae-Nam;Nam, Do-Hyun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.33-48
    • /
    • 2005
  • Differential diagnosis of articulation and resonance problems in the cleft lip and palate speech is required for evaluating various factors contribute to speech problems such as VPI, dental occlusion, palatal fistulae, learning. However, validity of speech stimuli is current issue to evaluate accurately each problem in cleft speech. This study was conducted to investigate speech stimuli using in the clinical setting and review the literatures and articles published 1990 to 2005 for helping develop standardized speech samples. The results were recommendation to evaluate properly velopharyngeal function when conducting a diagnostic evaluation as follows : 1) In identification hypernasality, the speech stimuli should be included low pressure consonants to eliminate effects of nasal emission, compensatory articulation. 2) Speech stimuli should be consist of visual, front sounds to eliminate compensatory articulation and to stimulate easily. 3) Regarding early diagnosis and treatment, speech stimuli need to develop for infants and preschooler. 4) Stimulus length on nasalance scores should be at least 6 syllables. 5) In phonetic context on nasalance scores, /i/ vowel should be take into consideration excluding paragraph. 6) Connected speech stimuli should be developed for evaluating intelligibility and VP function.

  • PDF

Automatic Virtual Camera Control Using Motion Area (모션 면적을 이용한 버추얼 카메라의 자동 제어 기법)

  • Kwon, Ji-Yong;Lee, In-Kwon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.2
    • /
    • pp.9-17
    • /
    • 2008
  • We propose a method to determine camera parameters for character motion, which confiders the motion by itself. The basic idea is to approximately compute the area swept by the motion of the character's links that are orthogonally projected onto the image plane, which we call "Motion Area". Using the motion area, we can determine good fixed camera parameters and camera paths for a given character motion in the off-line or real-time camera control. In our experimental results, we demonstrate that our camera path generation algorithms can compute a smooth moving camera path while the camera effectively displays the dynamic features of character motion. Our methods can be easily used in combination with the method for generating occlusion-free camera paths. We expect that our methods can also be utilized by the general camera planning method as one of heuristics for measuring the visual quality of the scenes that include dynamically moving characters.

  • PDF

Changes in longitudinal craniofacial growth in subjects with normal occlusions using the Ricketts analysis

  • Bae, Eun-Ju;Kwon, Hye-Jin;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: This study was designed to define the Korean norm values for the Ricketts analysis. Methods: In this longitudinal study, lateral cephalograms of 31 subjects with normal occlusion were taken biennially from ages 9-19 years. Cephalometric measurements were performed. Parameters for which the 10-year change did not exceed one standard deviation were defined as unchanged. The means and standard deviations for the measured parameters were determined for each age group. Results: No significant changes in growth were observed in the molar relationship, incisor overjet, incisor overbite, mandibular incisor extrusion, interincisor angle, lower incisor tip (B1) to A point-Pogonion (A-PO) plane, upper incisor tip (A1) to A-PO plane, B1 inclination to A-PO, A1 inclination to A-PO, B1 inclination to Frankfurt plane (FH), convexity, lower facial height, facial axis, maxillary depth, maxillary height, palatal plane to FH, cranial deflection, ramus Xi position, or porion location. Continual changes over the 10 years of growth were observed in the maxillary first molar distal position to pterygoid true vertical plane, facial depth, mandibular plane to FH, anterior cranial length, mandibular arc, and corpus length. Conclusions: Clinicians can apply the Korean norms at age 9 as determined in this study when using the Ricketts analysis. The patient's age at the beginning of treatment and their sex should be taken into consideration when drawing visual treatment objectives.

Anterior Choroidal Artery Aneurysm Surgery : Ischemic Complications and Clinical Outcomes Revisited

  • Lee, Young-Sup;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.86-92
    • /
    • 2013
  • Objective : Surgical results for anterior choroidal artery (AChA) aneurysms have previously been reported as unsatisfactory due to inadvertent occlusion of the AChA, while the low incidence of AChA aneurysms hampers the accumulation of surgical experience. The authors reviewed their related surgical experience to document the ischemic complications and surgical outcomes. Methods : Identification of the AChA at its origin by rigorous visual scrutiny, careful microdissection, and meticulous clip placement to avoid the AChA origin are all crucial surgical maneuvers. A retrospective review of a surgical series of 62 consecutive cases of an AChA aneurysm between 2004 and 2012 was performed. Results : All patients, except for five (8.1%) with a small residual neck, showed complete aneurysm obliteration in postoperative angiographic evaluations. There was no incidence of procedure-related permanent AChA syndrome or oculomotor nerve palsy, while three (4.8%) patients suffered from transient AChA syndrome. The clinical outcomes [the 3-month modified Rankin Scale (mRS)] of the patients were related to their preoperative World Federation of Neurologic Surgeons (WFNS) grade. As regards the 3-month mRS, significant differences were found between patients with an unruptured aneurysm (WFNS grade 0; n=20), good-grade subarachnoid hemorrhage (WFNS grade 1-3; n=30), and poor-grade subarachnoid hemorrhage (WFNS grade 4-5; n=4). Conclusion : In surgical treatment of AChA aneurysms, a risk of AChA insufficiency can be minimized by taking every precaution to preserve the AChA patency and intraoperative monitoring. In addition, the surgical outcome is primarily determined by the preoperative clinical state.

PARALLAX ADJUSTMENT FOR REALISTIC 3D STEREO VIEWING OF A SINGLE REMOTE SENSING IMAGE

  • Kim, Hye-Jin;Choi, Jae-Wan;Chang, An-Jin;Yu, Ki-Yun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.452-455
    • /
    • 2007
  • 3D stereoscopic viewing of large scale imagery, such as aerial photography and satellite images, needs different parallaxes relative to the display scale. For example, when a viewer sees a stereoscopic image of aerial photography, the optimal parallax of its zoom-in image should be smaller than that of its zoom-out. Therefore, relative parallax adjustment according to the display scale is required. Merely adjusting the spacing between stereo images is not appropriate because the depths of the whole image are either exaggerated or reduced entirely. This paper focuses on the improving stereoscopic viewing with a single remote sensing image and a digital surface model (DSM). We present the parallax adjustment technique to maximize the 3D realistic effect and the visual comfort. For remote sensing data, DSM height value can be regarded as disparity. There are two possible kinds of methods to adjust the relative parallax with a single image performance. One is the DSM compression technique: the other is an adjustment of the distance between the original image and its stereo-mate. In our approach, we carried out a test to evaluate the optimal distance between a single remote sensing image and its stereo-mate, relative to the viewing scale. Several synthetic stereo-mates according to certain viewing scale were created using a parallel projection model and their anaglyphs were estimated visually. The occlusion of the synthetic stereo-mate was restored by the inpainting method using the fields of experts (FoE) model. With the experiments using QuickBird imagery, we could obtain stereoscopic images with optimized parallax at varied display scales.

  • PDF

Full Mouth Rehabilitation in Severely Worn Dentition (심한 교모증 환자의 완전 구강 회복)

  • Jung, Jae-Hyun;Choi, Min-Ho;Park, Young-Rok;Kim, Chang-Heon;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.247-256
    • /
    • 2003
  • The patient had bruxism and epilepsy tendency. Inadequate or unstable posterior support was identified due to severe anterior attrition and decreased occlusal vertical dimension. Prematurities of posterior occlusal and wear facets increased the function of anterior teeth, resulting in severe wear. Wear facets displayed sharply defined peripheries, which are matched on articulated diagnostic casts. Also the patient showed C III malocclusion tendency, and lost some facial contour with drooping corners on the mouth. In this case, the alteration of OVD (Occlusal Vertical Dimention) may provide a biologically compatible adjunct to the treatment such as dentofacial esthetics, improved visual proportion in facial heightand mechanical solutions to the force-management of the masticatory system. The patient requires extensive restorative treatment to regain appropriate function, esthetics and comfort. According to the report by Farhad Fays, the average vertical distance from the maxillary to the mandibular mucolabial reflection in the region of the central incisors is approximately 34mm. However, the vertical distance of this patient was found to be 32mm, which was necessary to add gauge 20-sheets to apply vertical dimension. A removable occlusal overlay splint, which restores OVD to the estimated optimalposition, is the general first trial. The patient was observed periodically for 6 weeks, while appropriate adjustments were made vertical dimension to function. When patient felt comfortable with the splint, the teeth were prepared, and provisional restorations are placed for 3 months. The provisional restoration was fabricated by a diagnostic wax-up. When the patient felt comfortable with the provisional restoration, the final restoration mimics OVD, function, and esthetics that have been developed in the treatment restorations. Restoration of the extremely worn dentition presents a substantial challenge to thedentists. Therefore, careful evaluation of the etiology, history, and factors associated with occlusal vertical dimension should be preceded prior to the appropriate treatment planning.

Neck Clipping of Giant Aneurysm in ICA Using Intra-Operative Temporary Balloon Occlusion and Suction Decompression Technique - A Case Report - (술중 풍선 확장을 이용한 일시적 근위부 결찰과 흡입, 감압술을 실시한 내경동맥의 거대동맥류 결찰 - 증례보고 -)

  • Weon, Keun Soo;Shin, Yong Sam;Park, Han Jun;Lee, Seung Un;Yun, Su Han;Cho, Ki Hong;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.165-169
    • /
    • 2001
  • Apatient, 51 years old woman, had suffered form headache and decrease of visual acuity. She had $3{\times}3cm$ sized giant aneurysm originated in cavernous and clinoid portion of left ICA(C4,C5) in the cerebral angiography. Before craniotomy, left CCA was exposed and 6F double lumen catheter was inserted in left ICA through the sheath. Pre-operative angiography was done. balloon catheter was positioned at the petrous portion of ICA. Eyebrow approach was done and giant aneurysm was exposed. The proximal blood flow was controlled with balloon dilatation and suction and decompression was tried, then multiple clips were applied. The loss of distal blood flow under intra-operative angiography was notified after clipping. The position of clips were repositioned to preserve blood flow & the rich flow was confirmed at distal part of clipping. In the post-operative cerebral angiography, the same finding was shown.

  • PDF

The Optical Tracking Method of Flight Target using Kalman Filter with DTW (DTW와 Kalman Filter를 결합한 비행표적의 광학추적 방법)

  • Jang, Sukwon
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.3
    • /
    • pp.217-222
    • /
    • 2021
  • EOTS(Electro-Optical Tracking System) is utilized in acquiring visual information to assess a guided missile's performance. As the missile travels so fast, it is almost impossible for operator to re-capture the lost target. The RADAR or telemetry data are used to re-capture the lost target however facilities to receive real time data is required, which constrains selection of tracking site. Unlike aforementioned data, pre-calculated nominal trajectory can be used without communication facility. This paper proposes a method to predict lost target's state by employing nominal trajectory. Firstly, observed trajectory and nominal trajectory are compared using DTW and current target's state is predicted. The predicted state is used as observation in Kalman filter's correction phase to predict target's next state. The plausibility of the proposed method is verified by applying on actual missile trajectory.