• Title/Summary/Keyword: Visual Stimulus

Search Result 281, Processing Time 0.03 seconds

Improving of the Fishing Gear and Development of the Automatic Operation System in the Anchovy Boat Seine- II Analysis of escaping behaviour of anchovy in relation to underwater light and towing flow velocity (기선권현망어업의 어구개량과 자동화조업시스템 개발- II 수중광 및 예망유속과 멸치의 도피반응 행동 분석)

  • 김용해;장충식;안영수;김형석
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.78-84
    • /
    • 2001
  • Escape behaviour of the anchovy (Engralius japonica, total length 4-7cm) at the inside wing net and bag net in the anchovy boat seine was observed by underwater video camera in order to clarify the relationship between visual stimulus of the gear or relative water flow inside gear and reacting behaviour. The vertical attenuation coefficient of underwater illuminance in the offshore of Keoje island and Tongyoung was ranged from 0.24 to 1.03 and it could be affect visual range and visual contrast of the fishing gear. The relative water flow at the joint part between inside wing and bagnet while towing was 1.5 times higher than at the middle part of inside wing or fore part of bag net, but it was estimated under than maximum swimming speed of 4-7 cm anchovy. The mean escaping number of anchovy from end part of inside wing of 30 cm mesh to out side for a minute within visual range of video camera was 455 and anchovy swimming forward from bag net through flapper was 308. These results revealed anchovy could escape as voluntary response in spite of higher visual stimulus or higher water flow.

  • PDF

PHYSIOLOGICAL INDICATORS OF EMOTION AND ATTENTION PROCESSES DURING AFFECTIVE AND ORIENTING AUDITORY STIULATION (청각자극에 의해 유발된 정서 및 주의반응의 생리적 지표)

  • Estate M. Sokhadze
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.291-296
    • /
    • 1998
  • In the experiment carried out on 20 college students, recorded were frontal, temporal and occipital EEG, skin conductance response, skin conductance level, heart rate and respiration rate during listening to two music fragments with different affective valences and white noise administered immediately after negative visual stimulation. Analysis of physiological patterns observed during the experiment suggests that affective auditory stimulation with music is able to selectively modulate autonomic and cortical activity evoked by preceding aversive visual stimulation and to restore initial baseline levels. On other hand, physiological responses to white noise, which does not possess emotion-eliciting capabilities, evokes response typical for orienting reaction after the onset of a stimulus and is rapidly followed by habituation. Observed responses to white noise were similar to those specific to attention only and had no evidence for any emotion-related processes. Interpretation of the obtained data is considered in terms of the role of emotional and orienting significance of stimuli, dependence of effects on the background physiological activation level and time courses of attention and emotion processes. Physiological parameters are summarized with regard to their potential utility in differentiation of psychological processes induced by auditory stimuli.

  • PDF

Analysis of Relationship between Structure and Acoustic Character of Natural Waterfall (자연폭포의 강조와 청각적 특성의 관계분석)

  • 정성관;박정길
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.1
    • /
    • pp.19-32
    • /
    • 1990
  • The perception of landscape structure can he formed mode clearly, with including an auditory stimulus to a visual aspect. The waterfall, as an landscape element, will be considered of not only it's function and structure in landscape architecture designing but also harmony with environment which it has been situated, and contribution to the public goad. The purpose of this study was to establish more 7rational and practical design theory for the construction of waterfall. The number of subjects investigated were 47 of waterfall located in Mt. Palgong. In this study, the acoustic character of the waterfalls were investigated as an excellent effect to mask easily sensible noises. The correlations between the structure of waterfalls and water 1a17ing sound, which were useful for waterfall design and construction, were examined. It was discovered that the position of double distance of waterfall height From the waterfall is significant in the visual and acoustic perception of waterfall.

  • PDF

Mental State Analysis Using Evoked Potentials (뇌유발전위 분석을 통한 심리 상태의 분석)

  • Chee, Y.J.;Park, K.S.;Lee, S.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.247-250
    • /
    • 1996
  • In this paper, we tried to analyze the mental states, especially alertness or degree of concentration, by analysis of Visual Evoked Potentials. Given task to the visual stimulation, there was warning signals to enhance the alertness of the subject. With the synchronization to the stimulus, we averaged the EP waves, and estimated the power spectrums to view difference between relatively less alerted state and more alerted state. Although there was no significant difference during the waiting for the stimuli, we could find some difference during task performing.

  • PDF

Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • Kim Gyu-Gyeom;Ko Jong-Sun;Park Byung-Rim
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF

Comparison of Accommodative System according to the Material and Font Size of Near Visual Media (근거리 시각매체의 재질과 글자크기에 따른 조절시스템의 비교)

  • Ha, Na-Ri;Kim, Chang-Jin;Jung, Su A;Choi, Eun Jung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose: This study was conducted to compare and analyze the accommodative system (accommodative response and accommodative lag) according to the material and font size of near visual media that we often encounter in daily life. Methods: Forty adult men and women aged 20 to 30 who not had specific ocular diseases and refractive surgery experience were examined to measure and compare the accommodative response according to the material of near visual media (print paper, newspaper, magazine, the I-Phone, LCD monitor) and font size (6, 8, 10, 12) by using both eyes open-view auto-refractometer. Results: The accommodative stimulus was $2.28{\pm}0.11D$ and the accommodative response was $1.66{\pm}0.30D$. The accommodative lag namely the difference between accommodative stimulus and accommodative response was $0.62{\pm}0.28D$. The accommodative response according to material of visual media using LCD monitor was $1.35{\pm}0.26D$ (p=0.00) and using the I-Phone was $1.55{\pm}0.25D$ (p=0.04). Both of them were statistically significant lower. The accommodative lag using LCD monitor was $0.93{\pm}0.24D$ (p=0.00) and using the I-Phone was $0.73{\pm}0.25D$ (p=0.04) and they were statistically significant higher. The accommodative response and accommodative lag according to font size were not statistically significant (p>0.05). Conclusions: During near working, the accommodative system was more affected by material than font size of visual media. Especially, visual media of non-luminous material (print paper, newspaper, magazine) are considered fewer burdens on eyes than luminous material (I-Phone, LCD monitor) in terms of accommodative system.

A Study of Visual Event-Related Potential P300 in Schizophrenia (정신분열병의 시각자극 사건유발전위 P300에 대한 연구)

  • Oh, Dong-Hoon;Nam, Jung-Hyun;Ahn, Dong-Hyun;Kim, Seok-Hyun;Choi, Joon-Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.40-48
    • /
    • 2004
  • Objective:Event-related potentials(ERPs) are electrical changes recorded at the surface of the scalp in response to stimulus presentation, and their latency and amplitude change according to cognitive processes. Through past studies of the auditory ERP in schizophrenia, the P300 has been reported to be statistically smaller and delayed in schizophrenia than comparison groups. However, studies of the visual ERP have not been systematically examined. The present study was designed to investigate the visual P300 in patients with schizophrenia and normal controls and to compare the pattern of P300 between them. Methods:The subjects were composed of patients(N=22) with schizophrenia by DSM-IV and normal controls(N=22). The visual ERPs were measured by the visual continuous performance test. P300 amplitude and latency measured on 5 scalp electrodes(Fz, Cz, Pz, $T_7$, $T_8$) were compared between patients and controls. Results:The P300 latencies measured on Fz, Cz, Pz, and $T_7$ electrodes were significantly longer in patients than controls(p<0.05). The P300 amplitudes in patients were smaller than controls. However, the difference between them was not statistically significant. Conclusion:Analysis of the visual ERPs showed that the P300 latency is significantly delayed and the P300 amplitude is slightly smaller in patients than controls. These results are similar to established studies of the auditory P300 in schizophrenia.

  • PDF

Comparative Study of Colour Recognition According to Background Lightness and Stimulus Size (배경의 밝기와 자극의 크기에 따른 색채 인지 비교 연구)

  • Hong, Ji-Young;Park, Yun-Sun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.61-70
    • /
    • 2015
  • This study, under the assumption that there may be a difference in colours recognized depending on background lightness and colour stimulus size, applied background lightness in a differential way and conducted an experiment by comparing the sizes of stimuli equivalent to $2^{\circ}$ and $10^{\circ}$. Based on the results, by reflecting the results of this experiment as a difference in colour recognition, which may occur when the input image is converted from a large-sized screen to a mobile-sized screen, power efficiency, one of the biggest issues, can be reflected in mobile devices and may contribute to effective three-dimensional image reproduction and image quality in 3-D or hologram as well as 2-D images.

The effects of microcrystalline hydroxyapatite containing toothpaste in the control of tooth hypersensitivity (지각과민증에 대한 미세결정형 수산화인회석 함유 치약의 임상적 효과)

  • Park, Jung-Ju;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.577-590
    • /
    • 2005
  • The purpose of this study was to evaluate the effects of toothpaste containing hydroxyapatite for patients who complained dental hypersensitivity. Before baseline of application of toothpaste with hydroxyapatite, tooth brushing instruction was done respectively and the several indices were measured at baseline, 2, 4, 8 weeks. Clinical indices were estimated, and responses to cold, compressive air, tactile stimulus were evaluated with verbal rating score. Relief effects and visual analogue scale were also evaluated. The results of this study were as follows 1. The occurrence rate of hypersensitivity in upper jaw was higher than that of lower jaws, and molar area showed more hypersensitivity than premolar and incisor area. Buccal site was hypersensitive followed by interproximal and lingual site. 2. Plaque index, gingival index and probing depth reduction were gradually improved after Tooth Brushing Instruction and using toothpaste. 3. Subjects showed most sensitive response to cold stimuli than compressive air and tactile stimuli. 4. The relief effect was increased during using tooth paste and complete relief was increased especially at 8 weeks. 5. Visual analogue scale was increased. In conclusion, it was confirmed that toothpaste containing microcrystalline hydroxyapatite have the relief effect of tooth hypersensitivity. During 8 weeks, stimulus responses were decreased and hypersensitivity relief effect was increased.

Development of Multiple-modality Psychophysical Scaling System for Evaluating Subjective User Perception of the Participatory Multimedia System (참여형 멀티미디어 시스템 사용자 감성평가를 위한 다차원 심물리학적 척도 체계)

  • Na, Jong-Gwan;Park, Min-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.89-99
    • /
    • 2004
  • A comprehensive psychophysical scaling system, multiple-modality magnitude estimation system (MMES) has been designed to measure subjective multidimensional human perception. Unlike paper-based magnitude estimation systems, the MMES has an additional auditory peripheral cue that varies with corresponding visual magnitude. As the simplest, purely psychological case, bimodal divided-attention conditions were simulated to establish the superiority of the MMES. Subjects were given brief presentations of pairs of simultaneous stimuli consisting of visual line-lengths and auditory white-noise levels. In the visual or auditory focused-attention conditions, only the line-lengths or the noise levels perceived should be reported respectively. On the other hand, in the divided-attention conditions, both the line-lengths and the noise levels should be reported. There were no significant differences among the different attention conditions. Human performance was better when the proportion of magnitude in stimulus pairs were identically presented. The additional auditory cues in the MMES improved the correlations between the magnitude of stimuli and MMES values in the divided-attention conditions.