• 제목/요약/키워드: Visual Inspection

검색결과 868건 처리시간 0.029초

품질 검사자의 외관검사 검출력 향상방안에 관한 연구 (A Study on the Improvement of Human Operators' Performance in Detection of External Defects in Visual Inspection)

  • 한성재;함동한
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.67-74
    • /
    • 2019
  • Visual inspection is regarded as one of the critical activities for quality control in a manufacturing company. it is thus important to improve the performance of detecting a defective part or product. There are three probable working modes for visual inspection: fully automatic (by automatic machines), fully manual (by human operators), and semi-automatic (by collaboration between human operators and automatic machines). Most of the current studies on visual inspection have been focused on the improvement of automatic detection performance by developing a better automatic machine using computer vision technologies. However, there are still a range of situations where human operators should conduct visual inspection with/without automatic machines. In this situation, human operators'performance of visual inspection is significant to the successful quality control. However, visual inspection of components assembled into a mobile camera module belongs to those situations. This study aims to investigate human performance issues in visual inspection of the components, paying more attention to human errors. For this, Abstraction Hierarchy-based work domain modeling method was applied to examine a range of direct or indirect factors related to human errors and their relationships in the visual inspection of the components. Although this study was conducted in the context of manufacturing mobile camera modules, the proposed method would be easily generalized into other industries.

자동외관검사를 위한 확률기반 불량 확인 알고리즘 개발 (Development of Probability Based Defect Verification Algorithm for Automatic Visual Inspection)

  • 김영흡;유선중
    • 반도체디스플레이기술학회지
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2017
  • The visual inspection of electronic parts consists of two steps: automatic visual inspection and verification inspection. In the stage of a verification inspection, the human inspector sequentially inspects all the areas which detected in the automatic inspection. In this study, we propose an algorithm to determine the order of verification inspection by Bayes inference well known in the field of machine learning. This is a method of prioritizing a region estimated to have a high probability of defect using experience data of past inspection. This algorithm was applied to the visual inspection of ultraviolet filters to verify its effectiveness. As a result of the comparison experiment, it was confirmed that the verification inspection can be completed 30% of the conventional method by adapting proposed algorithm.

  • PDF

IT를 활용한 PSC교량의 외관조사지원시스템 개발 (Visual Inspection System on PSC Bridges Using IT)

  • 오광진;최재호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.396-399
    • /
    • 2004
  • This study was performed to develop necessary Visual Inspection System for the PSC Bridges precision safety diagnosis which to enhance the efficiency and accuracy of visual inspection by using mobile PC and adopted IT. This system was constructed to the automatic visual inspection map generating program and the Visual Inspection System using mobile PC that predicted high efficiency.

  • PDF

자동외관검사를 위한 검출위치 클러스터링 알고리즘 (Detected Point Clustering Algorithm For Automatic Visual Inspection)

  • 유선중
    • 반도체디스플레이기술학회지
    • /
    • 제13권3호
    • /
    • pp.1-6
    • /
    • 2014
  • Visual defect inspection for electronics parts manufacturing processes is comprised of 2 steps - automatic visual inspection by machine and inspection by human inspectors. It is necessary that spatial points which were detected by the machine should be adequately clustered for subsequent human inspection. This research deals with the spatial clustering algorithm for the purpose of process productivity improvement. Distribution based clustering is newly developed and experimentally confirmed to show better clustering efficiency than existing algorithm - area based clustering.

Multi-sensor Visual inspection for Seamless Steel Pipe´s Straightness

  • Tomoo, Aoyama;Zhang, Y.G.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.88.3-88
    • /
    • 2001
  • In this paper, an on-line multi-sensor visual inspection technique for seamless steel pipe´s straightness is developed. The basic principle of the visual measuring method is detailed. The modeling of visual sensor, measurement system and data processing are presented. In order to test the accuracy of the multi-sensor visual inspection, an experiment inspecting the straightness of a 1500mm long seamless steel pipe is made. The experiment results show that the visual inspection technique can achieve on-line measurement and offers high precision and stability.

  • PDF

국도 시설물 유지관리를 위한 현장점검시스템 개발 (The Development of Visual Inspection System for National Road Facility Maintenance Management)

  • 주기범;김태학;박상근
    • 한국전자거래학회:학술대회논문집
    • /
    • 한국전자거래학회 2003년도 종합학술대회 논문집
    • /
    • pp.72-77
    • /
    • 2003
  • 시설물의 손상현황을 파악하기 위한 현장점검업무는 의사결정과 유지보수공사를 위한 원천 정보를 생성하는 과정으로서 시설물 유지관리 Life Cycle에서 매우 중요한 부분을 차지하고 있다. 하지만, 수작업 및 중복입력 둥의 과다한 업무와 손상상태의 결정, 점검이력의 활용미비, 유지관리업무의 전문성 부족 등으로 효율성과 신뢰성을 갖춘 점검업무가 수행되지 못하고 있는 실정이다. 본 연구에서는 국도 상의 주요구조물인 교량, 터널, 지하차도 등을 대상으로 과다한 현장점검업무를 효율적으로 처리하고 점검결과에 신뢰성을 제공할 수 있는 현장점검시스템을 개발하였다. 현장점검업무의 분석과정에서 나타나는 문제점들을 파악하여 개선방안을 기능설계에서 반영하여 시스템화하였다. 본 시스템은 국도유지건설사무소에서 활용할 애정이며, 손상상태의 추적, 보수 물량 산출 등 유지관리 업무의 효율적인 관리가 가능해질 것으로 기대된다.

  • PDF

Study on Levee Visual Inspection Information System Building Using Mobile Technology

  • Kang, Seung-Hyun;Lee, Jong-Min
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.71-76
    • /
    • 2016
  • In this paper, we propose the mobile visual inspection information system using DGPS and portable range finder for levee safety inspection. Instead of existing visual inspection management method that is stored hand-written data, this system is designed to manage directly the visual inspection information using mobile devices in the field of levee. And through extracting accurate DGPS coordinates information about damage location of levee, this system is developed to ensure efficiency for the main task arising from the levee site such as inspection, maintenance and reinforcement. Furthermore, when damage has occurred at the point that inspector is not able to approach, this system can record the damage site data correctly, by converting data such as position, orientation and height of the damage point into the World Geodetic System coordinates. The position, orientation and height data was extracted automatically through the DGPS and portable range finder. And by applying the augmented reality method, this system was implemented for inspector to revisit the point of damage easily in order to perform the management, maintenance and reinforcement of the levee later.

안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구 (Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection)

  • 서재호;최진용;오환섭;박영배;박영재
    • 대한한의진단학회지
    • /
    • 제18권2호
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

"황제내경"의 국소부위 망형태(望形態)에 대한 연구 (Study on Diagnosis by Visual Inspection of Local Regions in Nei-Ching)

  • 서재호;김정균;김현호;박진성;박영배;박영재
    • 대한한의진단학회지
    • /
    • 제15권3호
    • /
    • pp.235-244
    • /
    • 2011
  • Objectives: There are four types of diagnostic methods in Oriental medicine, and visual inspection is the first method among them. This study was written in order to complement further understanding on visual inspection. Methods: The authors reviewed a word related with visual inspection in Nei-Ching. The authors researched static words such as bigger/smaller, longer/shorter, slower/faster, curved/straight, one-sided/fair, and groove/uplift, and active words such as extension and contraction, shake, tremor, slow, fast, walk, run, standing, lying, and sitting related with visual inspection in Nei-Ching. Results: The static words linked with visual inspection are related with skin, muscles, fat, and especially the liver, stomach, and large intestine. The active words linked with visual inspection are related with movement of muscles, fat, and bone. Conclusion: In this study, the authors provided further understanding on visual inspection in Nei-Ching. However, there was no clear reference point about appearances and movements.

A Sampling Inspection Plan with Human Error: Considering the Relationship between Visual Inspection Time and Human Error Rate

  • Lee, Yong-Hwa;Hong, Seung-Kweon
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.645-650
    • /
    • 2011
  • Objective: The aim of this study is to design a sampling inspection plan with human error which is changing according to inspection time. Background: Typical sampling inspection plans have been established typically based on an assumption of the perfect inspection without human error. However, most of all inspection tasks include human errors in the process of inspection. Therefore, a sampling inspection plan should be designed with consideration of imperfect inspection. Method: A model for single sampling inspection plans were proposed for the cases that visual inspection error rate is changing according to inspection time. Additionally, a sampling inspection plan for an optimal inspection time was proposed. In order to show an applied example of the proposed model, an experiment for visual inspection task was performed and the inspection error rates were measured according to the inspection time. Results: Inspection error rates changed according to inspection time. The inspection error rate could be reflected on the single sampling inspection plans for attribute. In particular, inspection error rate in an optimal inspection time may be used for a reasonable single sampling plan in a practical view. Conclusion: Human error rate in inspection tasks should be reflected on typical single sampling inspection plans. A sampling inspection plan with consideration of human error requires more sampling number than a typical sampling plan with perfect inspection. Application: The result of this research may help to determine more practical sampling inspection plan rather than typical one.