• Title/Summary/Keyword: Visual Angle

Search Result 614, Processing Time 0.027 seconds

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Changes of Qualities of Green Asparagus Packed with Different Types during Low Temperature Storage (포장 방법에 따른 아스파라거스의 저온저장 중 품질변화)

  • Wang, Lixia;Choi, In-Lee;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.239-244
    • /
    • 2020
  • Effect of 6kg large unit with the carton box (20% open ratio) and MA box (10,000cc·m-2·day-1·atm-1 oxygen transmission rates modified atmosphere package), and the 100g small unit with MA film on asparagus sensory quality were evaluated. The CO2 concentration depended largely on the packing unit and maintained at around 3% in small MA packages, whereas in the MA box increased to 12%. Ethylene concentration rapidly increased until after 3 days of storage in MA packages and then decreased to maintain 5μL·L-1. Unrelated to the unit size, the lower weight loss was obtained in MA packages. A significant difference in visual quality was shown since the 15th day, the best and worst were the MA box and small MA package on the finish day. Off-odor was the highest in small MA packages and the lowest in the carton box (< 3.0). Although there was no significant difference in firmness among all treatments, the packages showed the highest firmness in tips and stems, respectively. The sugar content and hue angle decreased during storage, but there was no statistical difference in all treatments. EL was lowest and highest in small MA package and carton box, respectively. On the 10th day, the total aerobic bacteria was lowest in small MA packages, but no significant difference on the 20th day. E. coli was not found in all treatments on the 10th day, while it was the lowest in the MA box on the 20th day. The mold and yeast were not observed during the whole storage. Based on the above results, the carton box packaged with 10,000cc OTR film was more effective in maintaining the quality of green asparagus with the suitable CO2 concentration for asparagus cold storage.

A Kinematical Analysis of Belle Motion on Parallel Bars (평행봉 Belle 기술동작의 운동학적 분석)

  • Kong, Tae-Ung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.43-53
    • /
    • 2005
  • This study is to define how the difference of athletic change influence on the last regrasp after somersault in Belle movement of parallel bars. For his study, the following conclusion was produced by analysis of athletic change by means of three dimensional visual image in three athlete of nation. 1. As the picture of S1, there are total used time(2.01 sec), S3(2.17 sec) and S2(2.19 sec). In case of a short needed time, it is difficult for them to perform the remaining movement of the vertical elevating flight easily and comfortably, it is judged as performing the small movement with restrict swing. 2 In the change of body center sped by each event, it is calculated as $-89.1^{\circ}$ the narrowest in S1, $-81.96^{\circ}$ the widest and then $86.34^{\circ}$ in S3. In E3 event, average compound speed is 4.07m/s, S2 showed the fastest speed of 4.14m/s whereas S1 the narrowest angle of 3.95m/s. 3. A shoulder joint and coxa are the period of mention in E3. In E4 which was pointed out the longest vertical distance, S2 that is indicated the highest vertical height as the period of detach in parallel bars. showed -3.91m. This is regarded as a preparatory movement for dynamic performance after using effectively elastic movement of shoulder joint and coxa while easily going up with turning back movement. In the 5th phrase, long airborne time and vertical change position is showed as the start while regrasping securely air flight movement from high position. 4. In E5, a long flight time and a long vertical displacement were shown as the regrasp after somersault efficiently in high position with stability from the point of the highest peak of the center of the body. Especially, S2 is marked as a little bit long position, while S1 is reversely indicated as performing somersault and unstable motion in a low position. 5. In E3, at the point of the largest extension of the shoulder joint and hip joint the shoulder joint is largely marked in $182^{\circ}$ and the hip point $182^{\circ}$ in S2. The shoulder joint is marked at the smallest angle in $177^{\circ}$ and the hip point $176^{\circ}$ in S1. And S1 is being judged by its performance of the less self - confident motion with lessening a breath of swing. S2 makes the most use of flexion and extension of the shoulder joint and the hip joint effectively. It was performed greatly with swinging and dropping the rotary movement and the rotary inertia naturally. 6. In E6, as the point of regrasp of the upper arm in parallel bars it is recognized by the that of components of vertical and horizontal velocity stably. During this study, the insufficient thing and the study on the parallel bars at a real game later are more activated than now. If it is really used as the basic materials by means of Belle Picked Study of Super E level after Bell movement, you may perceive the technique movement previously and perform without difficulty. Especially, such technique as crucifix is quite advantageous for oriental people thanks to small body shape condition. In conclusion we will nicely prepare for our suitable environment to gradually lessen trials and errors by analyzing and studying kinematically this movement.

Radiographic Changes of the Medial Epicondyle in Little League Baseball Player (청소년기 야구선수의 주관절 내상과의 방사선학적 변화)

  • Choi Chang-Hyuk;Eum Dong-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.43-48
    • /
    • 2002
  • Purpose : We evaluated radiographic changes and clinical manifestations of the elbow joint to identify the effects of the throwing between dominant and non-dominant arms. Materials and Methods : A hundred and five little leaguer’s baseball player in 5 elementary school and 2 middle school were evaluated for clinical symptoms and radiographic changes about elbow joint. Mean age was 12 years old and average periods of exercise were 32 months. Elbow functions were evaluated using ASES standardized assessment form and radiographic changes of medial epicondyle were examinated for enlargement, separation of the apophyses, fragmentation and irregularity. Results : Thirty seven players (35$\%$) were complained pain with throwing and the average score was 4.8 using visual analog scale. There were no significant differences in range of motion except flexion angle, valgus angle, and strength between dominant arm and non-dominant arm. Valgus laxity was more prominent in dominant arm. Ulnohumeral tenderness, radiocapitellar tenderness and medial flexor origin tenderness were in 18, 6, and 17 cases respectively in dominant arm. Medial epicondyle was enlarged in dominant arm with 13.0 by 6.3 mm compared to non-dominant arm with 11.7 by 6.1 mm. Apophyseal separation was 0.8 mm in dominant arm and 0.5 mm in non-dominant arm. Fragmentation and irregularity were 14 (13$\%$) and 25 (24$\%$) cases respectively in dominant arm. Conclusion : In little league baseball player, it needs usage of ball and bat with appropriate weight, and careful conditioning programs through throwing exercise in order to avoid elbow injuries.

  • PDF

Effects of Chlorine Water and Plasma Gas Treatments on the Quality and Microbial Control of Latuca indica L. Baby Leaf Vegetable during MA Storage (염소수와 플라즈마 가스 처리가 왕고들빼기 어린잎채소의 MA저장 중 품질과 미생물 제어에 미치는 영향)

  • Kim, Ju Young;Han, Su Jeong;Whang, Lixia;Lee, Joo Hwan;Choi, In-Lee;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.197-203
    • /
    • 2019
  • This study was carried out to investigate the effect of chlorine water and plasma gas treatment on the quality and microbial control of Latuca indica L. baby Leaf during storage. Latuca indica L. baby leaves were harvested from a plant height of 10cm. They were sterilized with $100{\mu}L{\cdot}L^{-1}$ chlorine water and plasma-gas (1, 3, and 6hours), and packaged with $1,300cc{\cdot}m^{-2}{\cdot}day^{-1}{\cdot}atm^{-1}$ films and then stored at $8{\pm}1^{\circ}C$ and RH $85{\pm}5%$ for 25days. During storage, the fresh weight loss of all treatments were less than 1.0%, and the carbon dioxide and oxygen concentrations in packages were 6-8% and 16-17%, respectively for all treatments in the final storage day. The concentration of ethylene in the packages fluctuated between $1-3{\mu}L{\cdot}L^{-1}$ during the storage and the highest concentration of ethylene was observed at 6 hours plasma treatment in the final storage day. The off-odor of all treatments were almost odorless, the treatments of chlorine water and 1 hour plasma maintained the marketable visual quality until the end of storage. Chlorophyll content and Hue angle value measured at the final storage day were similar to those measured before storage in chlorine water and 1 hour of plasma treatments. E. coli was not detected immediately after sterilization in all sterilization treatments. After 6 hours of plasma treatment, the total bacteria fungus counts were lower than the domestic microbial standard for agricultural product in all sterilization treatments. The total aerobic counts in the end storage day increased compared to before storage, whereas E. coli was not detected in all sterilization treatments. The sterilization effect against bacteria and fungi was the best in chlorine water treatment. Plasma treatment showed sterilization effects, but within a prolonged period of time. In addition, the sterilization effect decreased gradually. These results suggest that chlorine water and plasma treatment were effective in maintaining Latuca indica L. baby Leaf commerciality and controlling microorganisms during postharvest storage.

Image Watermarking for Copyright Protection of Images on Shopping Mall (쇼핑몰 이미지 저작권보호를 위한 영상 워터마킹)

  • Bae, Kyoung-Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.4
    • /
    • pp.147-157
    • /
    • 2013
  • With the advent of the digital environment that can be accessed anytime, anywhere with the introduction of high-speed network, the free distribution and use of digital content were made possible. Ironically this environment is raising a variety of copyright infringement, and product images used in the online shopping mall are pirated frequently. There are many controversial issues whether shopping mall images are creative works or not. According to Supreme Court's decision in 2001, to ad pictures taken with ham products is simply a clone of the appearance of objects to deliver nothing but the decision was not only creative expression. But for the photographer's losses recognized in the advertising photo shoot takes the typical cost was estimated damages. According to Seoul District Court precedents in 2003, if there are the photographer's personality and creativity in the selection of the subject, the composition of the set, the direction and amount of light control, set the angle of the camera, shutter speed, shutter chance, other shooting methods for capturing, developing and printing process, the works should be protected by copyright law by the Court's sentence. In order to receive copyright protection of the shopping mall images by the law, it is simply not to convey the status of the product, the photographer's personality and creativity can be recognized that it requires effort. Accordingly, the cost of making the mall image increases, and the necessity for copyright protection becomes higher. The product images of the online shopping mall have a very unique configuration unlike the general pictures such as portraits and landscape photos and, therefore, the general image watermarking technique can not satisfy the requirements of the image watermarking. Because background of product images commonly used in shopping malls is white or black, or gray scale (gradient) color, it is difficult to utilize the space to embed a watermark and the area is very sensitive even a slight change. In this paper, the characteristics of images used in shopping malls are analyzed and a watermarking technology which is suitable to the shopping mall images is proposed. The proposed image watermarking technology divide a product image into smaller blocks, and the corresponding blocks are transformed by DCT (Discrete Cosine Transform), and then the watermark information was inserted into images using quantization of DCT coefficients. Because uniform treatment of the DCT coefficients for quantization cause visual blocking artifacts, the proposed algorithm used weighted mask which quantizes finely the coefficients located block boundaries and coarsely the coefficients located center area of the block. This mask improves subjective visual quality as well as the objective quality of the images. In addition, in order to improve the safety of the algorithm, the blocks which is embedded the watermark are randomly selected and the turbo code is used to reduce the BER when extracting the watermark. The PSNR(Peak Signal to Noise Ratio) of the shopping mall image watermarked by the proposed algorithm is 40.7~48.5[dB] and BER(Bit Error Rate) after JPEG with QF = 70 is 0. This means the watermarked image is high quality and the algorithm is robust to JPEG compression that is used generally at the online shopping malls. Also, for 40% change in size and 40 degrees of rotation, the BER is 0. In general, the shopping malls are used compressed images with QF which is higher than 90. Because the pirated image is used to replicate from original image, the proposed algorithm can identify the copyright infringement in the most cases. As shown the experimental results, the proposed algorithm is suitable to the shopping mall images with simple background. However, the future study should be carried out to enhance the robustness of the proposed algorithm because the robustness loss is occurred after mask process.

Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1 (초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계)

  • Kim, Se-Jin;Ko, Jung-Hui;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.409-415
    • /
    • 2011
  • Purpose: To design applied anamorphic lens that focal length ratio is 3:1 optical system to improve detecting distance. Methods: We defined a boundary condition as $50^{\circ}{\sim}60^{\circ}$ for viewing angle, horizontal direction 36mm, vertical direction 12 mm for focal length, f-number 4, $15{\mu}m{\times}15{\mu}m$ for pixel size and limit resolution 25% in 33l p/mm. Si, ZnS and ZnSe as a materials were used and 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$ as a wavelength were set. optical performance with detection distance, narcissus and athermalization in designed camera were analyzed. Results: F-number 4, y direction 12 mm and x direction 36 mm for focal length of the thermal optical system were satisfied. Total length of the system was 76 mm so that an overall volume of the system was reduced. Astigmatism and spherical aberration was within ${\pm}$0.10 which was less than 2 pixel size. Distortion was within 10% so there was no matter to use as a thermal optical camera. MTF performance for the system was over 25% from 33l p/mm to full field so it was satisfied with the boundary condition. Designed optical system was able to detect up to 2.9 km and reduce a diffused image by decreasing a narcissus value from all surfaces except the 4th surface. From sensitivity analysis, MTF resolution was increased on changing temperature with the 5th lens which was assumed as compensation. Conclusions: Designed optical system which used anamorphic lens was satisfied with boundary condition. an increasing resolution with temperature, longer detecting distance and decreasing of narcissus were verified.

A Study on Automated Lineament Extraction with Respect to Spatial Resolution of Digital Elevation Model (수치표고모형 공간해상도에 따른 선구조 자동 추출 연구)

  • Park, Seo-Woo;Kim, Geon-Il;Shin, Jin-Ho;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.439-450
    • /
    • 2018
  • The lineament is a linear or curved terrain element to discriminate adjacent geological structures in each other. It has been widely used for analysis of geology, mineral exploration, natural disasters, and earthquake, etc. In the past, the lineament has been extracted using cartographic map or field survey. However, it is possible to extract more efficiently the lineament for a very wide area thanks to development of remote sensing technique. Remotely sensed observation by aircraft, satellite, or digital elevation model (DEM) has been used for visual recognition for manual lineament extraction. Automatic approaches using computer science have been proposed to extract lineament more objectively. In this study, we evaluate the characteristics of lineament which is automatically extracted with respect to difference of spatial resolution of DEM. We utilized two types of DEM: one is Shuttle Radar Topography Mission (SRTM) with spatial resolution of about 90 m (3 arc sec), and the other is the latest world DEM of TerraSAR-X add-on for Global DEM with 12 m spatial resolution. In addition, a global DEM was resampled to produce a DEM with a spatial resolution of 30 m (1 arc sec). The shaded relief map was constructed considering various sun elevation and solar azimuth angle. In order to extract lineament automatically, we used the LINE module in PCI Geomatica software. We found that predominant direction of the extracted lineament is about $N15-25^{\circ}E$ (NNE), regardless of spatial resolution of DEM. However, more fine and detailed lineament were extracted using higher spatial resolution of DEM. The result shows that the lineament density is proportional to the spatial resolution of DEM. Thus, the DEM with appropriate spatial resolution should be selected according to the purpose of the study.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF