• Title/Summary/Keyword: Visual Angle

Search Result 614, Processing Time 0.024 seconds

The configuration analysis for the storyboard image (스토리보드 이미지 구성 분석)

  • Lim, Woon-Joo
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.403-408
    • /
    • 2013
  • The configuration analysis for the image appeared in the storyboard as the 1st stage to change the scenario to the image expressed the visual phenomenon image starting from the literalism. The simultaneity of description on the interpretative level of the narrative description may describe various information multiple simultaneously, the relationship has been presented as a lot of these information has been weaved as one episode. The incident time of narrative description as the scene described mainly objectively and illustratively has been used usefully to present the accurate information for characters or incidents. The time series of narrative description appeared as one episode by expressing various spaces or images under the continuity of flow according to the time. The collision image seen from the angle of internal ignition played a role to create the meaning colliding into each other or interconnecting symbolic effects appeared as respectively fragmented image, the continuity of space played a role of expressing the different symbol when the image of completely different space is connected to one context, the continuity of time as well makes a different symbolism by interpreting symbols appeared as each images under the flow of time. These results show that the narrative description may be expressed in accordance with the narrative structure from the viewpoints of narrative description, but the internal ignition may be interpreted through the cultural and periodical background widely known in those years based on the experience and information capability the audiences are keeping not by any descriptive structure. Images appeared in the internal ignition appeared by colliding into each other or amplifying mutually no related scenes and revealing the overall symbolism by reinterpreting again.

Neural Activation in the Somatosensory Cortex by Electrotactile Stimulation of the Fingers: A Human fMRI Study

  • Seok, Ji-Woo;Jang, Un-Jung;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • Objective: The aim of this study is to investigate 1) somatotopic arrangement of the second and third fingers in SI area 2) difference of neural activation in the SI area produced by stimulation with different frequencies 3) correlation between the intensity of tactile perception by different stimulus intensity and the level of brain activation measurable by means of fMRI. Background: Somatosensory cortex can obtain the information of environmental stimuli about "where" (e.g., on the left palm), "what" (e.g., a book or a dog), and "how" (e.g., scrub gently or scrub roughly) to organism. However, compared to visual sense, the neural mechanism underlying the processing of specific electrotactile stimulus is still unknown. Method: 10 right-handed subjects participated in this study. Non-painful electrotactile stimuli were delivered to two different finger tips of right hand. Functional brain images were collected from 3.0T MRI using the single-shot EPI method. The scanning parameters were as follows: TR and TE were 3000, 35ms, respectively, flip angle 60, FOV $24{\times}24cm$, matrix size $64{\times}64$, slice thickness 4mm (no gap). SPM5 was used to analyze the fMRI data. Results: Significant activations produced by the stimulation were found in the SI, SII, the subcentral gyrus, the precentral gyrus, and the insula. In all participants, statistically significant activation was observed in the contralateral SI area and the bilateral SII areas by the stimulation on the fingers but ipsilaterally dominant. The SI area representing the second finger generally located in the more lateral and inferior side than that of the third finger across all the subjects. But no difference in brain area was found for the stimulation of the fingers by different frequencies. And two typical patterns were observed on the relationship between the perceived psychological intensity and the amount of voxels in the primary sensory cortex during the stimulation. Conclusion: It was possible to discriminate the representation sites in the SI by electrotactile stimulation of digit2 and digit3. But we could not find the differences of the brain areas according to different stimulation frequencies from 3 to 300Hz. Application: The results of the study can provide a deeper understanding of somatosensory cortex and offer the information for tactile display for blinds.

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

Development of Ultrasonic Waveguide Sensor for Under=Sodium Viewing in Liquid Metal Reactor (액체금속로 소듐내부 가시화를 위한 초음파 웨이브가이드 센서 개발)

  • Joo, Young-Sang;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.18-24
    • /
    • 2006
  • Reactor core and internal structures of a liquid metal reactor (LMR) can not be visually examined due to an opaque liquid sodium. The under-sodium viewing technique by using an ultrasonic wave should be applied far the visual inspection of reactor internals. In this study, an ultrasonic waveguide sensor with a strip plate has been developed for an application to the under-sodium viewing technique. The Lamb wave propagation of a waveguide sensor has been analyzed and the zero-order antisymmetric $A_0$ plate wave was selected as the application mode of the sensor. The $A_0$ plate wave can be propagated in the dispersive low frequency range by using a liquid wedge clamped to the waveguide. A new technique is presented which is capable of steering the radiation beam angle of a waveguide sensor without a mechanical movement of the sensor assembly The steering function of the ultrasonic radiation beam can be achieved by a frequency tuning method of the excitation pulse in the dispersive range of the $A_0$ mode. The technique provides an opportunity to overcome the scanning limitation of a waveguide sensor. The beam steering function has been evaluated by an experimental verification. The ultrasonic C-scanning experiments are performed in water and the feasibility of the ultrasonic waveguide sensor has been verified.

Design of Aspheric Imaging Optical System having 24mm Focal Length for MWIR with Facing Symmetric Lenses (마주보는 대칭렌즈를 가지는 MWIR용 초점거리 24mm의 비구면 결상광학계 설계)

  • Lee, Sang-Kil;Kim, Boo-Tae;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.183-189
    • /
    • 2018
  • This study deals with the design and development of imaging optics having 24mm focal length for MWIR ($3{\sim}5{\mu}m$) with two symmetrical lenses facing each other. We used CodeV in our optical design, and we performed the optimization process to have the resolution and angle of view satisfying the user's requirements. The materials of lenses were limited to two types, including KCIR035 with a refractive index of 1.7589, developed in Korea. The optical system designed in this way consists of two aspherical lenses made of KCIR035 material having the same shape and one spherical lens made of Si. Here, the arrangement of the two aspherical lenses is characterized by having a symmetrical structure facing each other. And this optical system has a resolution of MTF value of 0.35 or more at a line width of 20 lp / mm. Therefore, it is considered that this optical system has the capability to be applied to a thermal imaging camera using a $206{\times}156$ array MWIR detection device having a pixel size of $25{\mu}m$.

What Effects Does Necrotic Area of Contrast-Enhanced MRI in Osteoporotic Vertebral Fracture Have on Further Compression and Clinical Outcome?

  • Lee, Ja Myoung;Lee, Young Seok;Kim, Young Baeg;Park, Seung Won;Kang, Dong Ho;Lee, Shin Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.181-188
    • /
    • 2017
  • Objective : The objective of this study was to analyze the correlation between further compression and necrotic area in osteoporotic vertebral fracture (OVF) patients with contrast-enhanced magnetic resonance imaging (CEMRI). In addition, we investigated the radiological and clinical outcome according to the range of the necrotic area. Methods : Between 2012 and 2014, the study subjects were 82 OVF patients who did not undergo vertebroplasty or surgical treatment. The fracture areas examined on CEMRI at admission were defined as edematous if enhancement was seen and as necrotic if no enhancement was seen. The correlation between further compression and the necrotic and edematous areas of CEMRI, age, and bone mineral density was examined. Also, necrotic areas were classified into those with less than 25% (non-necrosis group) and those with more than 25% (necrosis group) according to the percentages of the entire vertebral body. For both groups, further compression and the changes in wedge and kyphotic angles were examined at admission and at 1 week, 3 months, and 6 months after admission, while the clinical outcomes were compared using the visual analog scale (VAS) and Eastern Cooperative Oncology Group (ECOG) performance status grade. Results : Further compression was $14.78{\pm}11.11%$ at 1 month and $21.75{\pm}14.43%$ at 6 months. There was a very strong correlation between the necrotic lesion of CEMRI and further compression (r=0.690, p<0.001). The compression of the necrosis group was $33.52{\pm}12.96%$, which was higher than that of the non-necrosis group, $14.96{\pm}10.34%$ (p<0.005). Also, there was a statistically significantly higher number of intervertebral cleft development and surgical treatments being performed in the necrosis group than in the non-necrosis group (p<0.005). Moreover, there was a statistical difference in the decrease in the height of the vertebral body, and an increase was observed in the kyphotic change of wedge angle progression. There was also a difference in the VAS and ECOG performance scales. Conclusion : The necrotic area of CEMRI in OVF had a strong correlation with further compression over time. In addition, with increasing necrosis, intervertebral clefts occurred more frequently, which induced kyphotic changes and resulted in poor clinical outcomes. Therefore, identifying necrotic areas by performing CEMRI on OVF patients would be helpful in determining their prognosis and treatment course.

A Study on Media Property of Timelapse (타임랩스 영상의 미디어적 특성에 관한 연구)

  • Chung, Kue-Hyung
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.215-233
    • /
    • 2016
  • Timelapse which was appeared Georges Mellieoseu in 1897 was not familiar to people and was not popular in film or broadcast industry in spite of long history. But about 5 years ago, timelapse has become distinguished in all around image art, because it show us aesthetic extraction of time and variation of color in Vimeo and Youtube which neve been seen before. So nowadays latest camera has come out with default menu which can shoot timelapse. But popularity of timelapse seem not development of cinematography technique or appearance of new function but production of image which reflects ages of present with fully accept digital media property. This study is approached from two formative characteristics. First it is strengthen of time which is showed timelapse and analog media from a comparison angle. Second, it is how to extend their sense and imitate images through resolution which can be possible high quality image and color especially with Raw data Through these methodology, this study defines correlation of character of digital media and artistic value of images in timelapse. And also it cleary assures the era of penetrating art has not only visual amusement as known but, also representative value of our ages and technology of media.

Producing True Orthophoto Using Multi-Dimensional Spatial Information (다차원공간정보를 이용한 실감정사영상 제작 방안)

  • Lee, Hyun-Jik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.3
    • /
    • pp.241-253
    • /
    • 2008
  • Recently, it is appearing that new paradigm of urban planning that ubiquitous concept such as the u-City, uECO-City is introduced while is rising necessity about third dimensional geo-spatial information of high quality for urban area. Orthophoto can manufacture by expense and time that is less easily than digital map using personal computer even if is not highly technician and according as position relation between manmade feature and natural feature is equal, can get information of distance, angle, horizontal and vertical position coordinate of topographic, area etc.. directly through orthophoto. Also, visual effect is good that orthophoto is expressed by image and interpretation is easy to detailed part of topographic. Manufacture and practical use are consisting in various field, for it is having advantage that can recognize information effectively than digital map. Therefore, this study presents a way of generating a detailed DSM for producing a true-orthphoto of the urban area, and this study also presents a way to produce an optimum true-orthophoto for an urban area by investigating through experiment the optimum variable for the geometric and radiometric correction of the orthophoto. This study also examined the potentials of the thesis by building a 3-dimensional city model of the model region with the above thesis on optimum generating method.

The Role of Bone Cement Augmentation in the Treatment of Chronic Symptomatic Osteoporotic Compression Fracture

  • Kim, Hyeun-Sung;Kim, Sung-Hoon;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.490-495
    • /
    • 2010
  • Objective : Bone cement augmentation procedures such as percutaneous vertebroplasty and balloon kyphoplasty have been shown to be effective treatment for acute or subacute osteoporotic vertebral compression fractures. The purpose of this study was to determine the efficacy of bone cement augmentation procedures for long standing osteoporotic vertebral compression fracture with late vertebral collapse and persistent back pain. Methods : Among 278 single level osteoporotic vertebral compression fractures that were treated by vertebral augmentation procedures at our institute, 18 consecutive patients were included in this study. Study inclusion was limited to initially, minimal compression fractures, but showing a poor prognosis due to late vertebral collapse, intravertebral vacuum clefts and continuous back pain despite conservative treatment for more than one year. The subjects included three men and 15 women. The mean age was 70.7 with a range from 64 to 85 years of age. After postural reduction for two days, bone cement augmentation procedures following intraoperative pressure reduction were performed. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period after bone cement augmentation procedures was 14.3 months (range 12-27 months). The mean injected cement volume was 4.1 mL (range 2.4-5.9 mL). The unipedicular approach was possible in 15 patients. The mean pain score (visual analogue scale) prior to surgery was 7.1, which decreased to 3.1 at 7 days after the procedure. The pain relief was maintained at the final follow up. The kyphotic angle improved significantly from $21.2{\pm}4.9^{\circ}$ before surgery to $10.4{\pm}3.8^{\circ}$ after surgery. The fraction of vertebral height increased from 30% to 60% after bone cement augmentation, and the restored vertebral height was maintained at the final follow up. There were no serious complications related to cement leakage. Conclusion : In the management of even long-standing osteoporotic vertebral compression fracture for over one year, bone cement augmentation procedures following postural reduction were considered safe and effective treatment in cases of non-healing evidence.

Developement of Scope for Military Rangefinder Using Schmidt Prism and Biprism Theory of Optometric Instrument (안광학기기에 사용되는 바이프리즘원리와 슈미트 프리즘을 이용한 군사 거리측정기용 스코프 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.167-175
    • /
    • 2015
  • Purpose: The new-type rangefinder, which is using the biprism principle, is introduced to develop the range finder which can be easily carried by soldiers, and in order to realize those technologies specifically, we try to develop a scope for military rangefinder by doing optical design which can secure enough space to move the biprism. Methods: After setting up the verious initial condition to realize two kinds of goals, that are the securement of enough space to move the biprism and the easy-exchangeability of two kinds of biprisms, and then the optical system was optimized by using optical design program CodeV in order to minimize the finite ray aberrations. Results: We designed the biprism housing to makes it possible to swap the two kinds of biprisms. It was appeared that the Schmidt prism is suitable as erecting prism which can make sure the space to move the biprism. 16.5 mm was good for the face length of Schmidt prism. The optical system with a Schmidt prism and a biprism was designed, and the finite ray aberrations was minimized. Conclusions: We developed a 5X scope for an optical rangefinder using a biprism and a Schmidt prism with 16.5 mm face length. This scope is valid for the optical system which has the effective field angle of ${\pm}3.6^{\circ}$, and the finite ray aberrations are well controlled within the ${\pm}8.95^{\prime}$.