• Title/Summary/Keyword: Visual Angle

Search Result 616, Processing Time 0.04 seconds

Development and Applications of New Thermochromism Inks used Chiral Nematic Liquid Crystal-UV Curing Resin (키랄네마틱 液晶-UV경화형 수지를 이용한 새로운 온도변색성 잉크의 개발 및 응용)

  • 김준곤;남수용;구철회;윤종태;심성보
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.2
    • /
    • pp.113-124
    • /
    • 2000
  • It is well known that the characteristics of liquid crystal polymer composite(LCPC) films are possessed of large-area and flexible display, polarizer free, high contrast, wide angle of visual filed and high responsiveness. In this study, we have investigated to the best optimal mixing rates chiral nematic liquid crystals and UV-curable resins having different properties acrylate moleculars. The purpose of this study has been the development of new functional application with liquid crystal polymer composite films. For example the films were applied a new thermal sensor. In results, best phase separation behaviors turned out liquid crystal/monomer/oilgomer mixture system.

  • PDF

A Study on Techniques to Evaluate Auditorium Assignment Visible Efficiency (객석배치 대안의 가시성능 평가 및 예측기술에 관한 연구)

  • Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.106-113
    • /
    • 2012
  • A study on techniques to evaluate auditorium assignment visible efficiency using three-dimensional simulation. The most important thing to be considered is to ensure the visibility to the podium upon assigning auditorium of venues, classrooms or seminar rooms. However, since there are so many variables to be considered such as the form of the stage, the area and height of the stage, size of screen, and the distance and angle of the auditorium from the podium, the methods to assign auditorium are staying at the level of basic for a long time. Thus, in this study, we proposed simulation methodology to quantitatively evaluate the three-dimensional visible efficiency based on Visual Graph Analysis (VGA) theory. After analytical methodology manufactures application, it sets examples of visibility depending on location of screen, visibility depending on degree of height difference and visibility about three-dimensional Mass Zoning like a stage and verifies the efficacy. In addition, based on results, visibility expectation curve is drawn and the method to calculate the stepped height depending on necessary visibility is proposed.

  • PDF

Development of GPS Simulation Tool Kit for Personal Computer (PC를 이용한 GPS Simulation System 개발)

  • 양원재;전승환;박계각
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.4
    • /
    • pp.219-226
    • /
    • 2000
  • Ship's position data obtaining method is one of the very important factor in navigation. Nowadays, GPS(Global Positioning System) using the earth orbiting satellites are equipped and operated for the position finding. Because it provides more precise position information than other equipments and is very convenient for navigator. In this study, it is designed to develop the GPS simulator for everybody being able to practise the GPS operating skill like as navigation planning, navigation calculating etc. And also, it can be operated with personal computer without real GPS receiver. This simulation system is based on the real GPS receiver and built by the visual basic 5.0 program. And it displays the ship's position and navigating information and plots the ship's moving track on the screen in real time according as initial setup data-main engine's rpm, rudder angle, departure position and waypoint.

  • PDF

A Measuring System for the Joint Rotations and the Myoelectric Signals of Human Arm Movements (팔운동의 관절 회전및 근전신호 측정 시스템)

  • Son, Jae-Hyun;Lee, Kwang-Suk;Hong, Sung-Woo;Ji, Seong-Hyon;Nam, Moon-Hyon
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.113-123
    • /
    • 1993
  • The aim of this study is to design a electrogoniometer for the measurement of three dimensional human elbow joint rotations. Using this device and visual monitor, we measured the angle of elbow joint rotations during the goal-directed movements. And we extracted myoelectric signals(MES) to verify the inter-relationship of elbow joint activities and constructed a system for the analysis of the spectrum for MES. The data obtained from this system will be used for the controller signal of prosthetic arm.

  • PDF

Tracking Control of a Moving Target Using a Robot Vision System

  • Kim, Dong-Hwan;Cheon, Gyung-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.77.5-77
    • /
    • 2001
  • A Robot vision system with a visual skill so as take information for arbitrary target or object has been applied to auto-inspection and assembling system. It catches the moving target with the manipulator by using the information from the vision system. The robot needs some information where the moving object will place after certain time. A camera is fixed on a robot manipulator, not on the fixed support outside of the robot. It secures wider working area than the fixed camera, and it dedicates to auto scanning of the object. It computes some information on the object center, angle and speed by vision data, and can guess grabbing spot by arriving time. When the location ...

  • PDF

A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System (반사거울 방식을 이용한 중정 내 자연채광 성능 분석 연구)

  • Park, Byung-Yoon;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.112-121
    • /
    • 2011
  • To lead lighting inside, design solution and mechenical solution can be used.A inner court and atrium are samples for design solution. However, physical and environmental elements for building design are not taken positively into consideration. So low position of the inner court is difficult to reach lighting performance and a urban landscape gets damaged. On this study, selecting a building with a inner court, best design method is suggested to apply reflecting mirror. building direction, building shape and solar position are considered to deside the setting angle for reflecting mirror. Performance for the setting reflecting mirror is verified through various simulation cases, and is got more lighting performance than the present situation on the building inside.

A Study on Marker-based Detection Method of Object Position using Perspective Projection

  • Park, Minjoo;Jang, Kyung-Sik
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.1
    • /
    • pp.65-72
    • /
    • 2022
  • With the mark of the fourth industrial revolution, the smart factory is evolving into a new future manufacturing plant. As a human-machine-interactive tool, augmented reality (AR) helps workers acquire the proficiency needed in smart factories. The valuable data displayed on the AR device must be delivered intuitively to users. Current AR applications used in smart factories lack user movement calibration, and visual fiducial markers for position correction are detected only nearby. This paper demonstrates a marker-based object detection using perspective projection to adjust augmented content while maintaining the user's original perspective with displacement. A new angle, location, and scaling values for the AR content can be calculated by comparing equivalent marker positions in two images. Two experiments were conducted to verify the implementation of the algorithm and its practicality in the smart factory. The markers were well-detected in both experiments, and the applicability in smart factories was verified by presenting appropriate displacement values for AR contents according to various movements.

Development Process on the Control Software for Camera and Grating Articulation System Prototype (CGAS-P) of the Giant Magellan Telescope Multi-Object Astronomical and cosmological Spectrograph (GMACS)

  • Ji, Tae-Geun;Cook, Erika;Kelly, Evan;DePoy, Darren L.;Marshall, Jennifer;Lee, Hye-In;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.46.3-46.3
    • /
    • 2019
  • We present the control software and its development process for a prototype of the Camera and Grating Articulation System (CGAS) for GMACS, a wide-field, multi-object, moderate-resolution optical spectrograph for the Giant Magellan Telescope (GMT). The CGAS prototype is currently designed for the camera articulation controller as a miniature model of the GMACS. The camera articulation package (CAP) is a software that controls two stepper motors to adjust the camera angle. The package is developed using Visual C++ and runs on Windows 10. We discuss the architectural design and communication route between the high-end user software and the electronics hardware.

  • PDF

Effects of Combined Exercise Applying Sling Neurac Method on Pain and Cervical Alignment in 20s and 30s Adults with Forward Head Posture (슬링 뉴렉 기법을 적용한 복합운동이 전방머리자세 가진 20~30대 성인의 통증 및 목뼈정렬에 미치는 영향)

  • Jin-Wook Lee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.173-175
    • /
    • 2023
  • 최근 좌식생활과 컴퓨터사용의 증가로 전방머리자세 가진 젊은 성인이 증가하고 있으며 이를 개선하기 위한 슬링 뉴렉기법을 적용한 복합운동의 효과를 알아보고자 실시되었다. 이 연구의 결과 운동군에서 통증, 목뼈 앞굽은각, 중력중심선에서 유의한 감소가 나타났다(p<.001). 이러한 결과는 슬링뉴렉을 적용한 복합운동이 억제된 근육에 신경근 활성화와 근육의 재교육을 통해 통증 및 목뼈정렬에 긍정적인 역할을 한 것으로 생각되며 전방두부자세 개선을 위한 효율적인 중재 방법이 될 수 있는 가능성을 확인하였다.

  • PDF

Effects of 1-MCP and MA Storage Treatments for Long-Term Storage of Asparagus Spears (아스파라거스의 장기저장을 위한 1-MCP와 MA저장의 효과)

  • Yoon, Hyuk Sung;Choi, In-Lee;Baek, Jun Pill;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.118-122
    • /
    • 2016
  • This study was conducted to identify the effects of 1-MCP and the storage methods for maintaining the quality of asparagus spears. Asparagus spears treated 1-MCP stored in MA condition and perforated film (conventional condition) and 1-MCP non-treated used as control. The treated asparagus was stored at $4^{\circ}C$ for 40 days. The fresh weight loss rate was less than 0.2% in all MA (Modified atmosphere) storage treatments, including the 1-MCP treatment, and 1-MCP shown the less fresh weight loss rate in perforated film storage after 20 days storage. The carbon dioxide concentration within a package was 5-12% in MA storage, which is whith the tolerated range of maximum $CO_2$ content of asparagus spears in recommended CA or MA conditions. The oxygen content was maintained between 5 to 15% in MAP treatments. The ethylene content was lowest at the MA storage with 1-MCP treatment. Visual quality, off-flavor, soluble solid contents, and hue angle on the final storage day were higher in MA storage and the 1-MCP treatment and conventional MA storage did not show any significant differences. These results suggest that the 1-MCP treatment did not significantly affected the quality and storability of asparagus spears.