• Title/Summary/Keyword: Vision correction

Search Result 208, Processing Time 0.028 seconds

Individual Difference in the Decrease of Visual Acuity and the Change in Contrast Threshold According to the Level of Optically Induced Retinal Defocus (광학적으로 유발된 망막흐림의 정도에 따른 시력감소의 개인차와 인식 대비도의 변화)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.93-98
    • /
    • 2014
  • Purpose: We were aim to investigate individual difference of visual acuity (VA) decrease and the change of contrast threshold (CT) according to the level of optically induced retinal defocus. Methods: A total of 69 eyes were examined using consist of ten-graded decimal vision chart (Landolt's ring). After conducted full correction of subject's refractive error, a monocular VA and CT were measured according to sequential increase by 0.25 D each time. Results: VA gradually decreased according to the increase of retinal defocus level. Individual difference of VA decrease was range from 1.2 to 0.6 in retinal defocus induced by +0.25 D. When retinal defocus was induced as much as +0.50 D and +0.75 D, it was in the range of 1.0 to 0.3 and 0.9 to 0.1 respectively. With +1.00 D, some participants didn't even recognize the 0.1 in the chart. With +1.75 D, whole participant did not recognize the 0.1. Also, CT was gradually decreased with increase of the retinal defocus level. Conclusions: Examiners should consider individual difference in the decrease of VA according to the level of residual refractive error when determining final prescription of a patient.

Clinical Review about Corrective Surgery of Tetralogy of Fallot (팔로사징증의 근치 수술에 관한 임상적 고찰)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.674-684
    • /
    • 1991
  • The surgical treatment of tetralogy of Fallot [TOF] was initiated by Blalock and Taussig in 1945 with the establishment of the subclavian artery to pulmonary artery anastomosis. In an imaginative and daring effort, in 1954, Lillehei and collaborators [1955] using controlled cross-circulation, carried out the first intracardiac repair of TOF by closing the ventricular septal defect [VSD] and relieving the pulmonary stenosis under direct vision. Nowadays, total correction is the ideal operation for treatment of TOF and is accomplished with extracorporeal circulation. And the results of surgery for TOF have steadily improved over the years, thanks to important contributions of many surgeons. Nevertheless because of its protean physiologic and anatomic presentation, TOF continues to offer challenges to cardiologist and cardiac surgeons. Thirty two cases of TOF have undergone total corrective surgery using extracorporeal circulation in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, Inje University, from Oct. 1985 to Feb. 1990. Clinical considerations were applied to these cases and the results were obtained as follows. 1. The heart lung machine used for extracorporeal circulation was SarnsO 7000, 5-head roller pump, and the number and type of oxygenators were 10 of bubble type and 22 of membrane type. The mean bypass time was 148.9 minutes and the mean aortic cross clamp time was 123.8 minutes. The GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 2. 20 cases were male and 12 were female, the mean age was 8 years old and the mean body weight was 25Kg. 3. The preoperative symptoms were cyanosis [29 cases], squatting [27 cases] and etc. The mean values of preoperative Hb., Hct., and SaO2 were 16.5 gm /dl, 50.3%, and 78.5%. 4. Combined anomalies were noticed in 16 cases [50%]. Among them 10 cases were PFO and 6 cases were ASD. 5. The degree of aorta overriding were 25% in 5 cases, 25 ~ 50% in 22 cases and above 50% in 5 cases. The dPA/Ao [ratio of diameter of pulmonary artery trunk to ascending aorta] were below 25% in 5 cases, 25 ~ 50% in 10 cases, 50 ~ 70% in 6 cases and above 75% in 11 cases. 6. The types of RVOT [right ventricular outflow tract] stenosis were valvular and infundibular in 14 cases [43.6%], diffuse hypoplastic type in 12 cases [37.5%], infundibular in 5 cases, and valvular and supravalvular in 1 case. 7. One stage radical corrective surgery was applied to the all cases. In widening of the RVOT, 3 types of patches were used: MVOP [monocusp ventricular outflow patch, Polystan BioprosthesesO] in 3 cases, knitted Dacron vessel patches in 2 cases, and double layer with bovine pericardium and woven Dacron prosthesis in 26 cases. 8. Postoperative complications were occurred in 15 cases. Among them, low output syndrome were occurred in 10 cases [31.3%] and 2 of them were expired postoperatively.

  • PDF

Assessment of Visual satisfaction & Visual Function with Prescription Swimming goggles In-air and Underwater (도수 수경 착용시 실내와 수중에서의 시각적 만족도 및 시력 평가)

  • Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.357-363
    • /
    • 2013
  • Purpose: To investigate the visual function with prescription swimming goggles. Methods: 15 university students (mean age: $22{\pm}1.54$ years) participated, with a mean distance refractive error of RE: S-1.67 D/C-0.40 D, LE: S-1.70D/C-0.37 D. Inclusion criteria were no ocular pathology, able to wear soft contact lenses to correct their refractive error to emmetropia and able to swim. Participants were fitted with contact lenses to correct all ametropia. Subjective evaluation for satisfaction of visual acuity, asthenopia and balance were also measured using a questionnaire while wearing swimming goggles with cylinder (C+1.50 D, Ax $90^{\circ}$) compared with plano sphere outside the swimming pool area. Visual acuity was assessed using the same ETDRS chart. The prescription swimming goggles powers were assessed in random order and ranged in power from S+3.00 D to S-3.00 D in 0.50 D steps. Results: Subjective evaluation was significantly worse for the swimming goggles with cylinder than for the plano powered goggles for all 3 questions, visual acuity, asthenopia and balance. Visual acuity were significantly affected by the different power of the swimming goggles (p<0.05), but there was no significant difference between the in-air in-clinic and underwater in-swimming pool measures (p=0.173). However, visual acuity measured in the clinic was significantly better than underwater for some swimming goggle powers (+3.00, +1.00, +0.50, 0, -1.00 and -2.00 D). Conclusions: Wearing swimming goggles underwater may degrade the visual acuity compared to within air but as the difference is less than 1 line of Snellen acuity, and it is unlikely to result in significant real-life effects. Having an incorrect cylinder correction was found to be detrimental resulting in lower score of satisfaction. Considering slippery floor of swimming pool area, it can be a potential risk factor. Therefore, it is important to correct any refractive error in addition to astigmatism for swimming goggle.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

A Study on the Measurement of Dynamic Visual Acuity according to the Change of Accommodative Stimulus (조절자극 변화에 따른 동체시력(Dynamic visual acuity) 측정에 관한 연구)

  • Jin, Moon-Seog;Jeon, In-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the difference in the dynamic visual acuity between (DVA) the distance and near and the effect of change of accommodative stimulus on the dynamic visual acuity by the addition of the plus lens. Methods : The study involved 40 male and female adults ($22.84{\pm}2.43$ years old) with over 1.0 of visual acuity and without systemic disease or ocular disease. We compared the distance and near DVA and the change of DVA induced by the addition of the plus lens(+0.50D, +1.00D, +1.50D). Results : The distance DVA and near DVA are $78.86{\pm}19.46deg/sec$ and $76.90{\pm}18.05deg/sec$ respectively. The distance DVA was slightly higher(p=0.04). The higher the distance DVA, the higher the positive correlation with the near DVA and distance DVA, and distance DVA was higher in those who had higher the near DVA(r=0.95, p=0.00, Fig. 4). The near DVA according to the change of accommodative stimulus was $75.95{\pm}18.85deg/sec$ in full correction and the near DVA with +0.50D spherical power was $76.95{\pm}16.45$ but there was no statistically significant differences(p>0.05). However, the near DVA with +1.00D spherical power was $79.02{\pm}13.51deg/sec$ and it was slightly higher. Also, the near DVA with +1.50D spherical power was $84.28{\pm}18.96deg/sec$, there and it was statistically significant difference(p<0.05). Conclusion : There is no difference between distance and near DVA, but near DVA is also excellent if distance DVA is good. The DVA increases as added a plus lens for controlled accommodative stimulation changes.

Effect on Myopia Progression Wearing Eye-glasses for School Children (학령기 아동의 안경착용이 근시진행에 미치는 영향)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.195-200
    • /
    • 2011
  • Purpose: We analyzed the influence of myopic's eye-glasses wearing on myopia progress after cycloplegic refraction. Methods: The 33 people (66 eyes) were school children from 8 years to 12 years having no experience eye-glasses wearing, they were taken cycloplegic refraction at the 100th, the 200th and 300th days in order to evaluate myopia progression. We investigated the eye-glasses wearing group (experimental group, 32 eyes) and the non-eye-glasses wearing group (control group, 34 eyes). The eye-glasses power of the experimental group were -0.50 D, -0.75 D, -1.00 D, -1.25 D and -1.50 D. We compared experimental group with control group for myopia progress according to period, age, and refraction error and investigated the myopia progress according to the eye-glasses power of experimental group. Results: At the 300th day from the first cycloplegic refaction, spherical equivalent for the experimental group increased as -1.03${\pm}$0.43 D (t=13.36, p<0.001) and for the control group increase as -0.61${\pm}$0.35 D (t=10.05, p<0.001) and two groups were statistical difference. Myopia power for experimental group increased 60.75%, for control group increased 56.66% at the 300 days. According to eye-glasses power increased 41.19${\pm}$15.25% at -1.50 D, 36.74${\pm}$19.29% at -1.25 D, 56.57${\pm}$20.21% at -1.00 D, 87.26${\pm}$49.38% at -0.75 D and 106.69${\pm}$59.60% at -0.50 D. Conclusions: The myopia power for the eye-glasses wearing group was 0.46 D faster than the non-eye-glasses wearing group at the 300th day from the first cycloplegic refraction. We will consider the effect of non-eye-glasses wearing to protect the progressing myopia and prescribe the under correction for school children having no experience eye-glasses wearing.

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF