• 제목/요약/키워드: Visible light fluorescence

검색결과 39건 처리시간 0.024초

아르곤 레이저 광감각법의 법랑질 우식증 조기탐지 효과에 관한 연구 (A STUDY ON THE EARLY DETECTION OF ENAMEL CARIES BY THE LUMINESCENCE EXCITED BY ARGON LASER)

  • 이난영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.313-324
    • /
    • 1997
  • The aim of the present study was to describe an safe and convenient method for the early detection of enamel caries using laser fluorescence. Fluorescence from natually carious lesion of human teeth illuminated by an argon laser(488nm) was observed and photographed using barrier filter. Intact enamel was found to fluorescence with a yellowish light. Whereas, incipient caries lesions in the enamel were dearly visible as dark areas in contrast to the fluorescence surroundings. For evaluation of accuracy of this method, lesion depth measured by the laser fluorescence in light microscope was compared with that polarizing microscope. The results from the present study can be summarized as follows : 1. Enamel caries of smooth surface was observed as pale white spot and undefined outline in ordinary light. Whereas, lesion was clearly visible as dark spot in laser fluorescence. 2. There was no difference between ordinary light view and laser fluorescence in occlusal surface and interproximal surface. 3. There was no significant difference between the lesion depth observed by laser fluorescence with light microscope and polarizing microscope. Apparent correlation exists between two groups.

  • PDF

근적외선-II 형광 이미징을 위한 무기 나노입자 (Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging)

  • 박용일
    • 공업화학
    • /
    • 제33권1호
    • /
    • pp.17-27
    • /
    • 2022
  • 형광 이미징은 시간 분해능과 공간 해상도가 높기 때문에 기초연구에서 세포나 소동물 이미징에 널리 활용된다. 기존의 형광 이미징은 가시광선 영역의 광원을 활용하기 때문에 조직 내 광투과도가 낮고, 광원에 의한 광독성이 생길 수 있으며, 자가형광에 의한 간섭으로 검출 민감도가 떨어지는 한계가 있다. 이러한 점을 개선하기 위해 에너지가 낮은 장파장의 광원을 활용하고자 하며, 700~900 nm 영역을 활용하는 근적외선-I 형광 이미징이 개발되었고, 이미징 성능을 대폭 향상시키기 위해서 1000~1700 nm 영역의 장파장을 이용하는 근적외선-II 이미징이 연구자들의 관심을 받고 있다. 근적외선-II 영역은 광산란이 최소화되어 생체조직 내 투과도를 약 10 mm까지 향상시킬 수 있고, 생체조직의 자가형광도 최소화되어 고민감도와 고해상도의 형광 이미징이 가능하다. 본 총설에서는 다양한 근적외선-II 형광 이미징 탐침 중에서 광안정성이 뛰어나고 발광 파장 조절이 용이한 무기 나노입자 기반 탐침에 대해 살펴보았고, 그 중에서 단층 탄소 나노튜브와 양자점 및 란탄족 나노입자에 대해 중점적으로 기술하였다.

자외선 유도 형광의 사과 성숙도 평가 적용 (UV/blue Light-induced Fluorescence for Assessing Apple Quality)

  • 노현권
    • Journal of Biosystems Engineering
    • /
    • 제35권2호
    • /
    • pp.124-131
    • /
    • 2010
  • Chlorophyll fluorescence has been researched for assessing fruit post-harvest quality and condition. The objective of this preliminary research was to investigate the potential of fluorescence spectroscopy for measuring apple fruit quality. Ultraviolet (UV) and blue light was used as an excitation source for inducing fluorescence in apples. Fluorescence spectra were measured from 'Golden Delicious' (GD) and 'Red Delicious' (RD) apples using a visible/near-infrared spectrometer after one, three, and five minutes of continuous UV/blue light illumination. Standard destructive tests were performed to measure fruit firmness, skin and flesh color, soluble solids and acid content from the apples. Calibration models for each of the three illumination time periods were developed to predict fruit quality indexes. The results showed that fluorescence emission decreased steadily during the first three minutes of UV/blue light illumination and was stable within five minutes. The differences were minimal in the model prediction results based on fluorescence data at one, three or five minutes of illumination. Overall, better predictions were obtained for apple skin chroma and hue and flesh hue with values for the correlation coefficient of validation between 0.80 and 0.90 for both GD and RD. Relatively poor predictions were obtained for fruit firmness, soluble solids content, titrational acid, and flesh chroma. This research has demonstrated that fluorescence spectroscopy is potentially useful for assessing selected quality attributes of apple fruit and further research is needed to improve fluorescence measurements so that better predictions of fruit quality can be achieved.

Synthesis and Characterization of Poly[9,10-diphenylanthracene-4$^\prime$, 4$^\prime^\prime$-ylenevinylene-3,6-(N-2-ethylhexyl)carbazole]

  • 김윤미;박기민;권순기
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권9호
    • /
    • pp.975-978
    • /
    • 2001
  • A novel poly[9,10-diphenylanthracene-4',4"-ylenevinylene-3,6-(N-2-ethyl hexyl)carbazole] containing alternate diphenylanthracene and carbazole unit was synthesized by the Wittig reaction. The obtained polymer was soluble in common organic solvents and thermally stable up to 380 $^{\circ}C.$ The polymer gives rise to bright blue fluorescence both in solution and in thin solid films. The light emitted from the device (ITO/polymer/Al) was greenish-blue in color and clearly visible in daylight.

Endoscopic Fluorescence Angiography with Indocyanine Green : A Preclinical Study in the Swine

  • Cho, Won-Sang;Kim, Jeong Eun;Kim, Sae Hoon;Kim, Hee Chan;Kang, Uk;Lee, Dae-Sic
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.513-517
    • /
    • 2015
  • Objective : Microscopic indocyanine green (ICG) angiography is useful for identifying the completeness of aneurysm clipping and the preservation of parent arteries and small perforators. Neuroendoscopy is helpful for visualizing structures beyond the straight line of the microscopic view. We evaluated our prototype of endoscopic ICG fluorescence angiography in swine, which we developed in order to combine the merits of microscopic ICG angiography and endoscopy. Methods : Our endoscopic ICG system consists of a camera, a light source, a display and software. This system can simultaneously display real-time visible and near infrared fluorescence imaging on the same monitor. A commercially available endoscope was used, which was 4 mm in diameter and had an angle of $30^{\circ}$. A male crossbred swine was used. Results : Under general anesthesia, a small craniotomy was performed and the brain surface of the swine was exposed. ICG was injected via the ear vein with a bolus dose of 0.3 mg/kg. Visible and ICG fluorescence images of cortical vessels were simultaneously observed on the display monitor at high resolution. The real-time merging of the visible and fluorescent images corresponded well. Conclusion : Simultaneous visible color and ICG fluorescent imaging of the cortical vessels in the swine brain was satisfactory. Technical improvement and clinical implication are expected.

성장배지 혈액 유무가 구강미생물의 적색 형광 발현에 미치는 영향 (Red fluorescence of oral bacteria is affected by blood in the growth medium)

  • 정승화;양용훈;이민아;김세연;김지수
    • Journal of Korean Academy of Oral Health
    • /
    • 제41권4호
    • /
    • pp.290-295
    • /
    • 2017
  • Objectives: Dental plaque emits red fluorescence under a visible blue light near the ultra-violet end of the light spectrum. The fluorescence characteristics of each microorganism have been reported in several studies. The aim of this study was to evaluate changes in red fluorescence of oral microorganisms that is affected by blood in the culture media. Methods: The gram-positive Actinomyces naeslundii (AN, KCTC 5525) and Lactobacillus casei (LC, KCTC 3109) and gram negative Prevotella intermedia (PI, KCTC 3692) that are known to emit red fluorescence were used in this study. Each bacterium was activated in broth and cultivated in different agar media at $37^{\circ}C$ for 7 days. Tryptic soy agar with hemin and vitamin $K_3$ (TSA), TSA with sheep blood (TSAB), basal medium mucin (BMM) medium, and BMM with sheep blood (BMMB) were used in this study. Fluorescence due to bacterial growth was observed under 405-nm wavelength blue light using the quantitative light-induced fluorescence-digital (QLF-D) device. The red, green, and blue fluorescence values of colonies were obtained using image-analysis software and the red to green ratio (R/G value) and red to total RGB ratio (R/RGB value) were calculated for quantitative comparison. Results: The QLF-D images of the AN, LC, and PI colonies showed red fluorescence in all media, but the fluorescence of all bacteria was reduced in TSA and BMM media, compared with in TSAB and BMMB media. Both the R/G and the R/RGB values of all bacteria were significantly reduced in growth media without blood (P<0.001). Conclusions: Based on this in vitro study, it can be concluded that red fluorescence of oral bacteria can be affected by growth components, especially blood. Blood-containing medium could be a significant factor influencing red fluorescence of oral bacteria. It can be further hypothesized that bleeding in the oral cavity can increase the red fluorescence of dental plaque.

A Cyan Fluorescent Protein Gene (cfp)-Transgenic Marine Medaka Oryzias dancena with Potential Ornamental Applications

  • Vu, Nguyen Thanh;Cho, Young Sun;Lee, Sang Yoon;Kim, Dong Soo;Nam, Yoon Kwon
    • Fisheries and Aquatic Sciences
    • /
    • 제17권4호
    • /
    • pp.479-486
    • /
    • 2014
  • To evaluate their potential utility as an ornamental organism, novel transgenic marine medaka Oryzias dancena strains with a highly vivid fluorescent phenotype were established through transgenesis of a cyan fluorescent protein gene (cfp) driven by the endogenous fast skeletal myosin light chain 2 gene (mlc2f) promoter. The transgenic marine medaka strains possessed multiple copies of transgene integrants and passed their fluorescent transgenes successfully to subsequent generations. Transgenic expression in skeletal muscles at both the mRNA and phenotypic levels was, overall, dependent upon transgene copy numbers. In the external phenotype, an authentic fluorescent color was dominant in the skeletal muscles of the transgenic fish and clearly visible to the unaided eye. The phenotypic fluorescent color presented differentially in response to different light-irradiation sources; the transgenics displayed a yellow-green color under normal daylight or white room light conditions, a strong green-glowing fluorescence under ultraviolet light, and a cyan-like fluorescence under blue light from a light-emitting diode.

The Synergistic Effect of Nitrogen and Ni2O3 over TiO2 Photocatalyst in the Degradation of 2,4,6-Trichlorophenol Under Visible Light

  • Hu, Shaozheng;Li, Fayun;Fan, Zhiping
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권12호
    • /
    • pp.4052-4058
    • /
    • 2012
  • The composite photocatalyst, N-$TiO_2$ loaded with $Ni_2O_3$, was prepared by $N_2$ plasma treatment. X-ray diffraction, X-ray fluorescence, $N_2$ adsorption, UV-vis spectroscopy, photoluminescence, and X-ray photoelectron spectroscopy were used to characterize the prepared $TiO_2$ samples. The results indicated that the band gap energy was decreased obviously by nitrogen doping, whereas loading of $Ni_2O_3$ did not influence the band gap and visible light absorption. The photocatalytic activities were tested in the degradation of 2,4,6-trichlorophenol (TCP) under visible light. The photocatalytic activity and stability of composite photocatalyst were much higher than that of catalyst modified with nitrogen or $Ni_2O_3$ alone. The synergistic effect of doping nitrogen and $Ni_2O_3$ over $TiO_2$ was investigated.

바이오 물질 분석을 위한 금속 나노입자를 이용한 SERS 분석 연구동향 (A Review of SERS for Biomaterials Analysis Using Metal Nanoparticles)

  • 장의순
    • 세라미스트
    • /
    • 제22권3호
    • /
    • pp.281-300
    • /
    • 2019
  • Surface enhanced Raman scattering (SERS) was first discovered in 1974 by an unexpected Raman signal increase from Pyridine adsorbed on rough Ag electrode surfaces by the M. Fleishmann group. M. Moskovits group suggested that this phenomenon could be caused by surface plasmon resonance (SPR), which is a collective oscillation of free electrons at the surface of metal nanostructures by an external light source. After about 40 years, the SERS study has attracted great attention as a biomolecule analysis technology, and more than 2500 new papers and 500 review papers related to SERS topic have been published each year in recently. The advantages of biomaterials analysis using SERS are as follows; ① Molecular level analysis is possible based on unique fingerprint information of biomolecule, ② There is no photo-bleaching effect of the Raman reporters, allowing long-term monitoring of biomaterials compared to fluorescence microscopy, ③ SERS peak bandwidth is approximately 10 to 100 times narrower than fluorescence emission from organic phosphor or quantum dot, resulting in higher analysis accuracy, ④ Single excitation wavelength allows analysis of various biomaterials, ⑤ By utilizing near-infrared (NIR) SERS-activated nanostructures and NIR excitation lasers, auto-fluorescence noise in the visible wavelength range can be avoided from in vivo experiment and light damage in living cells can be minimized compared to visible lasers, ⑥ The weak Raman signal of the water molecule makes it easy to analyze biomaterials in aqueous solutions. For this reason, SERS is attracting attention as a next-generation non-invasive medical diagnostic device as well as substance analysis. In this review, the principles of SERS and various biomaterial analysis principles using SERS analysis will be introduced through recent research papers.

레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용 (Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries)

  • 이병진
    • 대한치과의사협회지
    • /
    • 제49권8호
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.