• 제목/요약/키워드: Visible Distance

검색결과 212건 처리시간 0.028초

The Effect of Substrate Temperature on the Electrical, Electronic, Optical Properties and the Local Structure of Transparent Nickel Oxide Thin Films

  • Lee, Kangil;Kim, Beomsik;Kim, Juhwan;Park, Soojeong;Lee, Sunyoung;Denny, Yus Rama;Kang, Hee Jae;Yang, Dong-Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.397-397
    • /
    • 2013
  • The electrical, electronic, optical properties and the local structure of Nickel Oxide (NiO) thin film have been investigated by X-ray photoelectron spectroscopy (XPS), Reflection Electron Energy Loss Spectroscopy (REELS), UV-spectrometer,Hall Effect measurement and X-ray absorption spectroscopy (XAS). The XPS results show that the Ni 2p spectra for all films consist of $Ni2p_{3/2}$ at around 854.5 eV which indicate the presence of Ni-O bond from NiO phase and for the annealed film at temperature above $200^{\circ}C$ shows the coexist Ni oxide and Ni metal phase. The REELS spectra showed that the band gaps of the NiO thin films were abruptly decreased with increasing temperature. The values of the band gaps are consistent with the optical band gaps estimated by UV-Spectrometer. The optical transmittance spectra shows that the transparency of NiO thin films in the visible light region was deteriorated with higher temperature due to existence of $Ni^0$. Hall Effect measurement suggest that the NiO thin films prepared at relatively low temperatures (RT and $100^{\circ}C$) are suitable for fabricating p-type semiconductor which showed that the best properties was achieved at $100^{\circ}C$, such as a low resistivity of $7.49{\Omega}.cm$. It can be concluded that the annealing process plays a crucial role in converting from p type to n type semiconductor which leads to reducing electrical resistivity of NiO thin films. Furthermore, the extended X-ray absorption fine structure (EXAFS) spectrum at the Ni K-edge was used to address the local structure of NiO thin films. It was found that the thermal treatments increase the order in the vicinity of Ni atom and lead the NiO thin films to bunsenite crystal structure. Moreover, EXAFS spectra show in increasing of coordination number for the first Ni-O shell and the bond distance of Ni-O with the increase of substrate temperature.

  • PDF

가역 감온 변색 겔형 염화 코발트/polyvinyl butyral을 이용한 온도 감지 광섬유 센서 연구 (Studies on Optical-fiber Sensor to Monitor Temperature using Reversible Thermochromic Gel Type Cobalt (II) Chloride/Polyvinyl Butyral)

  • 황기섭;박재희;하기룡;이준영
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.436-442
    • /
    • 2014
  • 염화코발트 용액을 사용하여 전자기파와 진동에 영향을 받지 않는 원거리 실시간 광섬유 온도 감지 센서를 개발하였다. 염화코발트 용액을 제조하기 위하여, 물과 에탄올은 부피 비율로 10%와 90%로 고정하고, 용해되는 염화코발트의 양을 다양하게 변화시켰다. 제조된 염화코발트 용액은 자외-가시선 분광 광도계를 사용하여, 온도 변화에 따른 655 nm 파장의 투과도를 측정하였다. 또한 제조된 30.8 mM 염화코발트 수화물 용액에 polyvinyl butyral을 용해시켜 겔화한 후, 온도 변화에 따른 655 nm 파장의 투과도 측정 및 센서 적용 후 광 파워 분석을 실시하였다. 투과도와 광 파워 측정 결과, $25^{\circ}C$에서 66.8%와 149.5 nW, $70^{\circ}C$에서는 7.1%와 48 nW로 각각 나타나, 온도가 증가함에 따라 투과도와 광 파워 모두 감소하는 경향을 보였다. 본 실험에서 제조된 겔화 염화코발트/polyvinyl butyral은 온도 변화에 따라 655 nm 파장에 대한 광 투과도와 광 파워가 변하는 점을 이용하여 온도 변화를 감지하기 위한 광섬유 센서로 사용 가능함을 확인하였다.

Factors Related to the Diagnostic Yield of Flexible Bronchoscopy without Guidance in Bronchoscopically Invisible Peripheral Lung Lesions

  • Kang, Hye Seon;Ha, Jick Hwan;Kang, Hyeon Hui;Yeo, Chang Dong;Rhee, Chin Kook;Kim, Sung Kyoung;Moon, Hwa Sik;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • 제80권3호
    • /
    • pp.284-290
    • /
    • 2017
  • Background: We aimed to analyze the factors predicting the diagnostic performance of flexible bronchoscopy without guidance in peripheral lung lesions that are endoscopically invisible. Methods: This was a retrospective study conducted in St. Paul's Hospital, The Catholic University of Korea, between January 2007 and March 2013. We included all patients who received bronchoscopy during this period. The analyzed variables were age, sex, the etiology of the lesion, lesion size, distance from the pleura, and presence of the bronchus sign. We used multiple logistic regression analysis to identify the significant independent factors associated with diagnostic yield. Results: We included 151 patients in this study. The overall diagnostic yield was 58.3%. The sensitivity was 43.2% for malignant disease and 78.1% for benign disease. The benign lung lesions (p<0.001), lesion size (p=0.015), presence of the exposed type of bronchus sign (p<0.001), and presence of cavitary lung lesions (p=0.005) were factors influencing the yield of flexible bronchoscopy by univariate analysis. In a multivariate logistic regression analysis, the exposed type of bronchus sign and benign lung lesions were independent predicting factors (odds ratio [OR]: 27.95; 95% confidence interval [CI], 7.56-103.32; p<0.001 and OR, 4.91; 95% CI, 1.76-13.72; p=0.002). Conclusion: The presence of the exposed type of bronchus sign and benign lung lesions are determining factors of the diagnostic yield in flexible bronchoscopy in evaluating peripheral lesions that are not endoscopically visible.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • 황인찬;서관용
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF

다목적 실용위성 1호의 한반도 통과시각 결정을 위한 연구 (I): 태양 및 대기 변수 조사 (A STUDY FOR THE DETERMINATION OF KOMPSAT I CROSSING TIME OVER KOREA (I): EXAMINATION OF SOLAR AND ATMOSPHERIC VARIABLES)

  • 권태영;이성훈;오성남;이동한
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권2호
    • /
    • pp.330-346
    • /
    • 1997
  • 다목적 실용위성 1호 (KOMPSAT I)는 지도 제작, 해양관측, 우주 과학실험 등에 활용할 태양도기 저궤도용 위성으로 1999년 8~9월에 발사될 예정이다. 본 위성에 탑재될 고해상도 전자광학 카메라(Electro-Optical Camera: EOC)의 주임무는 한반도 표준지도 제작을 위한 위성영상정보의 획득이다. EOC 센서는 가시광선 영역의 흑백 단일 채널(510~730mm)을 통해 수직 촬영 시 최소 15km 이상의 폭과 궤도 800km의 길이를 지상 해상도 6.6m로 촬영한다. 본 연구에서는 아리랑 1호의 한반도 통과 시각을 결정하기 위하여 한반도 지역에 있어 EOC 영상에 커다란 영향을 미치는 태양 변수와 구름과 시정의 일변를 조사하였다. 조사 결과는 다음과 같다. 1) 동지의 경우 대략 오전 10시 30분 이후 태양 천장 각 의 $70^{\circ}$보다 작고, 예상되는 EOC 스펙트럼 밴드의 flux 값은 맑은 날씨 육지에서 약 $2.4mW/cm^2$보다 크다. 2) 낮 동안의 구름의 분포 (맑은 하늘의 분포)는 오전 11시경에 최소값(최대값)을 보이며, 비록 안개에 의한 악 시정의 발생 빈도는 정오로 갈수록 감소하나 맑은 하늘의 분포에 미치는 영향은 미약하다. 이러한 결과로부터 EOC 관측을 위해서는 다목적 실용위성 1호의 한반도 통과 시각을 오전 10시 30분에서 11시 30분 사이에서 결정하는 것이 적합하다고 판단된다.

  • PDF

과학기술위성3호 소형영상분광기 발사모델 환경시험 결과 (Environmental Test Results of a Flight Model of a Compact Imaging Spectrometer for a Microsatellite STSAT-3)

  • 이상준;김정현;이준호;이치원;장태성;강경인
    • 한국광학회지
    • /
    • 제22권4호
    • /
    • pp.184-190
    • /
    • 2011
  • 과학기술위성3호 부탑재체인 소형영상분광기 COMIS(Compact Imaging Spectrometer)는 400 - 1050 nm의 관측 대역에서 분광 관측을 수행하는 영상 분광기이다. COMIS는 2012년 고도 700 km의 원 궤도에서 발사 된 후 27 m의 공간분해능과 2 - 15 nm의 파장 분해능을 갖도록 설계되었다. 본 논문에서는 COMIS 비행 모델의 환경시험 수행결과를 기술한다. 발사 환경인 진동 가진에 의한 영상분광기의 광학적, 구조적인 변화 여부와 우주환경인 열.진공 상태에서의 기능 시험을 수행하여 안정성 및 신뢰성을 검증 받았다. 우주공간에서의 환경으로 일컬어지는 고진공($10^{-5}$ torr이하)과 $-30^{\circ}C{\sim}35^{\circ}C$의 고온 및 저온의 열적 변화 상태를 모사하는 시험에서 정상적인 기능을 보였고, 10 grms의 랜덤 진동 가진 전.후의 고유 진동수는 1% 이내의 변화량을 보였다. 환경시험 전 후로 영상분광기의 변조전달함수(MTF, Modulation Transfer Function) 측정을 하여 광학 성능이 유지됨을 확인하였다. 환경시험을 마친 영상분광기는 현재 과학기술위성3호 본체와의 조립을 진행 중에 있으며 2012년 발사 예정에 있다.

RF and Optical properties of Graphene Oxide

  • 임주환;;윤형서;오주영;정영모;박형구;전성찬
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.68.1-68.1
    • /
    • 2012
  • The best part of graphene is - charge-carriers in it are mass less particles which move in near relativistic speeds. Comparing to other materials, electrons in graphene travel much faster - at speeds of $10^8cm/s$. A graphene sheet is pure enough to ensure that electrons can travel a fair distance before colliding. Electronic devices few nanometers long that would be able to transmit charge at breath taking speeds for a fraction of power compared to present day CMOS transistors. Many researches try to check a possibility to make it a perfect replacement for silicon based devices. Graphene has shown high potential to be used as interconnects in the field of high frequency electrical devices. With all those advantages of graphene, we demonstrate characteristics of electrical and optical properties of graphene such as the effect of graphene geometry on the microwave properties using the measurements of S-parameter in range of 500 MHz - 40 GHz at room temperature condition. We confirm that impedance and resistance decrease with increasing the number of graphene layer and w/L ratio. This result shows proper geometry of graphene to be used as high frequency interconnects. This study also presents the optical properties of graphene oxide (GO), which were deposited in different substrate, or influenced by oxygen plasma, were confirmed using different characterization techniques. 4-6 layers of the polycrystalline GO layers, which were confirmed by High resolution transmission electron microscopy (HRTEM) and electron diffraction analysis, were shown short range order of crystallization by the substrate as well as interlayer effect with an increase in interplanar spacing, which can be attributed to the presence of oxygen functional groups on its layers. X-ray photoelectron Spectroscopy (XPS) and Raman spectroscopy confirms the presence of the $sp^2$ and $sp^3$ hybridization due to the disordered crystal structures of the carbon atoms results from oxidation, and Fourier Transform Infrared spectroscopy (FTIR) and XPS analysis shows the changes in oxygen functional groups with nature of substrate. Moreover, the photoluminescent (PL) peak emission wavelength varies with substrate and the broad energy level distribution produces excitation dependent PL emission in a broad wavelength ranging from 400 to 650 nm. The structural and optical properties of oxygen plasma treated GO films for possible optoelectronic applications were also investigated using various characterization techniques. HRTEM and electron diffraction analysis confirmed that the oxygen plasma treatment results short range order crystallization in GO films with an increase in interplanar spacing, which can be attributed to the presence of oxygen functional groups. In addition, Electron energy loss spectroscopy (EELS) and Raman spectroscopy confirms the presence of the $sp^2$ and $sp^3$ hybridization due to the disordered crystal structures of the carbon atoms results from oxidation and XPS analysis shows that epoxy pairs convert to more stable C=O and O-C=O groups with oxygen plasma treatment. The broad energy level distribution resulting from the broad size distribution of the $sp^2$ clusters produces excitation dependent PL emission in a broad wavelength range from 400 to 650 nm. Our results suggest that substrate influenced, or oxygen treatment GO has higher potential for future optoelectronic devices by its various optical properties and visible PL emission.

  • PDF

공간구문론과 GIS를 이용한 조망점 위치결정 (Locational Decision of the Viewpoint Using GIS and Space Syntax)

  • 최철현;정성관;이우성
    • 한국지리정보학회지
    • /
    • 제14권2호
    • /
    • pp.53-68
    • /
    • 2011
  • 경관평가에 있어서 선행되어져야 할 기본적이면서도 중요한 과정이 바로 조망점의 선정이다. 그러나 현재까지도 조망점의 선정방식은 정확한 지표나 근거없이 평가자의 주관적이고 인위적인 방식에 의해 선정되어 왔다. 따라서 본 연구에서는 GIS와 공간구문론을 이용하여 보다 객관적이고 정량화된 조망점 선정 방식을 제시하고자 하였다. 이를 위해 대구광역시에 위치한 삼덕3주거 개선지구를 대상으로 거리 및 방위에 의해 24개의 섹터로 가시권 범위를 분절하였다. 그 후, 공간구문론의 축선도 분석과 가시빈도 분석을 실시하여 공간적으로 균등하게 분포하는 후보조망점을 선정하였다. 조망점 가치판단지수를 통해 최종적인 조망점을 선정한 결과, 근경인 VP-2 조망점의 VEI값은 112.63, 중경인 VP-10 조망점은 18.31, 원경인 VP-18 조망점은 5.55로 분석되었으며, 모두 국채보상로 상에 위치하고 있었다. 선정된 조망점은 공공기관, 공원, 고밀도 주거공간 등과 같이 인구유동량이 많아 조망기회가 높고, 동시에 경관변화율이 큰 지점인 것으로 확인되었다. 이와 같이 조망점 가치판단지수는 조망점을 정량적으로 선정할 수 있는 객관적인 지표로서 활용될 수 있을 것으로 판단된다.

몬테 카를로 복사 전달 행렬 방법을 사용한 산란 대기에서 동작하는 단거리 3차원 플래시 라이다 시스템의 수치적 모델링 (Numerical Modeling of a Short-range Three-dimensional Flash LIDAR System Operating in a Scattering Atmosphere Based on the Monte Carlo Radiative Transfer Matrix Method)

  • 안해찬;나정균;정윤찬
    • 한국광학회지
    • /
    • 제31권2호
    • /
    • pp.59-70
    • /
    • 2020
  • 3차원 플래시 라이다 시스템(3D flash LIDAR system)에서의 대기 산란을 해석하기 위해 몬테 카를로 복사 전달(Monte Carlo radiative transfer, MCRT) 방법을 바탕으로 수정된 수치 해석 모델인 MCRT 행렬 방법을 논의한다. MCRT 방법을 바탕으로 라이다 신호의 복사 전달 함수를 행렬 형태로 구성하며, 이는 특성 응답에 해당한다. 근축 근사에 기반하여 본 특성 응답 행렬의 중첩 및 합성곱 연산을 활용함으로써 확장된 전반적인 플래시 라이다의 전산 모사 모델을 개발한다. MCRT 행렬 방법은 기존의 몬테 카를로 기반 방법들에서 과도하게 증가할 수 있는 개별 라이다 신호의 추적을 대폭 경감시킨다. 그 결과 본 방법은 다양한 산란 조건 및 라이다 시스템 구성 환경에서도 그 신호 응답을 빠르게 획득할 수 있는 특징을 지닌다. 본 논문에서는 MCRT 행렬 방법에 기반한 전산 모델을 이용하여 상이한 대기 환경 조건에서 동작하는 3차원 플래시 라이다 시스템을 그 산란 조건, 즉, 그 가시거리에 따른 산란 계수를 달리하며 모사하고, 플래시 라이다 신호의 신호대잡음비의 악화, 신호 오류, 시공간적 확산 및 시간 지연 등 시스템상에서의 산란 효과에 의해 나타나는 다양한 현상을 수치적으로 분석한다. MCRT 행렬 방법은 자율 주행을 위한 플래시 라이다 시스템을 포함해 다양한 라이다 시스템을 분석하는데 매우 효과적으로 사용될 수 있을 것으로 기대된다.