• Title/Summary/Keyword: Virtual flux estimation

Search Result 5, Processing Time 0.022 seconds

Improved Input Voltage Sensorless Control of Three-Phase AC/DC PWM PFC Converter using Virtual Flux Observer (가상자속관측기를 이용한 3상 AC/DC PWM PFC 컨버터의 입력전압 센서리스 제어 개선)

  • Kim, Young-Sam;So, Sang-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.566-574
    • /
    • 2013
  • In this paper, direct power control system for three-phase PFC AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the reduced-order virtual flux observer using the actual currents and the command control voltage. Moreover, source voltage sensors are replaced by a estimated flux. DC output voltage has been compensated by DC output ripple voltage estimation algorithm. The active and reactive powers estimation are performed based on the estimated flux and Phase angle. The proposed algorithm is verified through simulation and experiment.

Direct Power Sensorless Control of Three-Phase AC/DC PFC PWM Converter using Virtual Flux Observer (가상 자속관측기를 이용한 3상 AC/DC PFC PWM 컨버터의 직접 전력 센서리스 제어)

  • Kim, Young-Sam;Kwon, Young-Ahn
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1442-1447
    • /
    • 2012
  • In this paper, direct power control system for three-phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the Reduced-order flux observer using the actual currents and the command control voltage. The source voltage sensors are replaced by a flux estimator. The active and reactive powers estimation are performed based on the estimated flux and Phase anble. The proposed algorithm is verified through simulation and experiment.

Sensorless Control of 3-phase PFC AC/DC Converter using Kalman Filter (칼만필터를 이용한 3상 PFC AC/DC 컨버터의 센서리스 제어)

  • Park, Jun-Sung;Kwon, Young-Ahn
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.998-1004
    • /
    • 2016
  • This paper investigates a new sensorless control appling a virtual flux oriented vector control without the line voltage sensor for the power factor correction of 3 phase PWM converter. The DC output voltage is controlled by applying the kalman filter algorithm for the virtual flux estimation and the synchronous phase is obtained by using the estimated virtual flux equation based on kalman filter. This method is used to reduce the calculation time of the system and obtain a stable control that the input current including the harmonics and the noise is improved. The proposed system implement PFC algorithm in the variable region of DC output voltage. It can obtain the unity power factor, and can precisely control the DC output voltage in the load variation and in the variable voltage range. The performance of the proposed algorithm is verified through simulation and experiment.

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.

Virtual Flux Estimation Using Modified Integrator of a Three-Phase AC/DC Converter for Direct Power Control (3상 AC/DC 컨버터의 직접 전력 제어를 위해 개선된 적분기를 적용한 가상 자속 추정 기법)

  • Seo, Seung Gyu;Cho, Yongsoo;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.399-400
    • /
    • 2015
  • 본 논문에서는 개선된 적분기를 이용하여 3상 AC/DC 컨버터의 직접 전력 제어(Direct Power Control)를 위한 가상 자속의 추정 기법을 제안한다. 기존의 가상 자속 추정을 위해 사용하는 일반적인 적분기는 dc drift 문제를 유발한다. 이는 보통 저역 통과 필터를 사용으로 보완이 가능하지만, 이 경우 추정된 자속은 크기와 위상의 오차를 갖는다. 따라서 제안하는 기법은 각속도 오차가 가상 자속의 위상 지연 오차와 비례하는 관계를 분석하고 이를 보상하여 속응성 및 안정성을 향상시킨다. 시뮬레이션을 통하여 제안한 기법의 타당성을 검증한다.

  • PDF