• 제목/요약/키워드: Viewing-angle

Search Result 487, Processing Time 0.029 seconds

Review of Applicability of Analysis Method based on Case Study on Rainfall-Induced Rock Slope Failure (강우에 의한 암반사면 파괴 해석 사례 연구를 통한 해석방법 적용성 검토)

  • Jung, Jahe;Kim, Wooseok
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • Behavior of rock mass depend on the mechanical properties of intact rock and geometrical property of discontinuity distributed in rock mass. In case of rock slope, particularly, location of slope failure surface and behavior after failure are changed due to discontinuities. In this study, two 3D slope stability analysis methods were developed for two different failure types which are circular failure and planar failure, considering that failure type of rock slope is dependent on scale of discontinuity which was then applied to real rock slope to review the applicability. In case of circular failure, stable condition was maintained in natural dry condition, which however became unstable when the moisture content of the surface was increased by rainfall. In case of planar failure, rock slope become more unstable comparing to dry condition which is attributable to decrease in friction angle of discontinuity surface due to rainfall. Viewing analysis result above, analysis method proved to have well incorporated the phenomenon occurred on real slope from the analysis result, demonstrating its applicability to reviewing the slope stability as well as to maintaining the slope.

Endoscopic Spinal Surgery for Herniated Lumbar Discs

  • Shim, Young-Bo;Lee, Nok-Young;Huh, Seung-Ho;Ha, Sang-Soo;Yoon, Kang-Joan
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.4
    • /
    • pp.241-245
    • /
    • 2007
  • Objective : So called "minimally invasive procedures" have evolved from chemonucleolysis, automated percutaneous discectomy, arthroscopic microdiscectomy that are mainly working within the confines of intradiscal space to transforaminal endoscopic technique to remove herniated epidural disc materials directly. The purpose of this study is to assess the result of endoscopic spinal surgery and favorable indication in the thoracolumbar spine. Methods : The records of 71 patients, 73 endoscopic procedures, were retrospectively analysed. Yeung Endoscopic Spine Surgery system with 7 mm working sleeve and $25^{\circ}$ viewing angle was used. The mean follow up period was 6 months [range, 3-9]. Results : Operated levels were from T12-L1 disc down to L5-L6 of S1 disc. Of 71 cases, 2 patients underwent transforaminal endoscopic surgery twice due to recurrence after initial operation. MacNab's criteria was used to assess the outcome. Favorable outcome, excellent of good, was seen in 78% [57 procedures] of the patients. Among 11 fair outcomes, only 1 procedure was followed by secondary open procedure, laminectomy with discectomy. Two of 5 poor outcomes were operated again by same procedure which resulted in fair outcomes. One patient with aggravated cauda equina syndrome remained poor and a lumbar fusion procedure was performed in other patient with poor outcome. There were 2 postoperative discitis that were treated with conservative care in one and anterior lumbar interbody fusion in the other. Conclusion : Evolving technology of mechanical, visual instrument enables minimal invasive procedure possible and effective. The transforaminal endoscopic spinal surgery can reach as high as T12-L1 disc level. The rate of favorable outcome is mid-range among reported endoscopic lumbar surgery series. Authors believe that the outcome will be better as cases accumulate and will be able to reach the fate of standard open microsurgery.

Image Enhancement Using Error Diffusion with APL in PDP (APL 적용 오차 확산법을 이용한 PDP 화질 개선)

  • Jang Soo-Wook;Pyo Se-Jin;Lee Sung-Hak;Sohng Kyu-Ik;Kim Eun-Su
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1360-1368
    • /
    • 2005
  • PDP is the flat panel display, suitable for high definition television because of large-sire and high-brightness. It has many advantages such as fast response, wide viewing angle, low weight, and simple manufacturing process for fabrication. However, there are some disadvantages and one of them is the image quality degradation, which is dependent on the digital signal processing. Although image quality of PDP is improving by many researches and experimentations, it still isn't as good as that of CRT because of various factors. One of them is worm-like pattern generated by an error diffusion process. And the worm-like pattern is severely increased after an APL process. An increased worm-like pattern occur a drop of resolution in image and a change of CCT according to each grayscale. In this paper, a method for improvement of image quality using the error diffusion which considers the APL process is proposed. In the proposed method, the APL process is performed before the error diffusion process. Simulation results showed that the proposed method has better performances for resolution in images and CCT uniformity according to each grayscale than the conventional method.

  • PDF

Development of LTPS-integrated gate driver circuit for OCB-mode LCD panel (OCB 모드 LCD 패널을 위한 LTPS 집적 게이트 구동 회로 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.528-531
    • /
    • 2007
  • This paper presents development of a 4-inch WVCA OCB (Optical Compensated Bend)-mode display panel. The developed panel has a built-in circuit of the LTPS (low temperature poly-Si)-integrated gate driver circuit with the function of black data insertion. The function of black data insertion makes it possible to realize rapid response time of 4ms and wide viewing angle of $160^{\circ}$. We also applied the RGBW pixel structure for the brighter image with relatively low power consumption. The developed panel showed improved optical efficiency and driving capability of stable image quality for OCB mode. We developed high efficiency OCB-mode panel with built-in integrated gate driver circuit using LTPS on panel without any external driver IC.

  • PDF

License Plate Recognition System based on Normal CCTV (일반 CCTV 기반 차량 번호판 인식 시스템)

  • Woong, Jang Ji;Man, Park Goo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.89-96
    • /
    • 2017
  • This Paper proposes a vehicle detection system and a license plate recognition system from CCTV images installed on public roads. Since the environment of this system acquires the image in the general road environment, the stable condition applied to the existing vehicle entry / exit system is not given, and the input image is distorted and the resolution is irregular. At the same time, the viewing angle of the input image is more wide, so that the computation load is high and the recognition accuracy of the plate is likely to be lowered. In this paper, we propose an improved method to detect and recognize a license plate without a separate input control devices. The vehicle and license plate were detected based on the HOG feature descriptor, and the characters inside the license plate were recognized using the k-NN algorithm. Experimental environment was set up for the roads more than 45m away from the CCTV, Experiments were carried out on an entry vehicle capable of visually identifying license plate and Experimental results show good results of the proposed method.

SAR Test-bed to Acquire Raw Data and Form Real-time Image (실시간 영상형성 및 원시데이터 획득용 SAR 테스트 베드)

  • Shin, Hyun-Ik;Kwon, Kyoung-Il;Yoon, Sang-Ho;Kim, Hyung-Suk;Hwang, Jeonghun;Ko, Young-Chang;You, Eung-Noh;Kim, Jin-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.181-186
    • /
    • 2017
  • Synthetic aperture radar(SAR) has been widely used for reconnaissance. It provides high-resolution, day-and-night and weather-independent images for a multitude of applications. Because SAR coherently combines many viewing angles to effectively create a large aperture(narrow beam) radar, the test-bed should be capable of moving straightly SAR sensor for the integration angle to meet resolution. This paper describes the test-bed developed to test and evaluate the SAR performance. It forms high-quality images in real time and saves the raw data for the purpose of post processing on the ground.

Laser Thermal Processing System for Creation of Low Temperature Polycrystalline Silicon using High Power DPSS Laser and Excimer Laser

  • Kim, Doh-Hoon;Kim, Dae-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.647-650
    • /
    • 2006
  • Low temperature polycrystalline silicon (LTPS) technology using a high power laser have been widely applied to thin film transistors (TFTs) for liquid crystal, organic light emitting diode (OLED) display, driver circuit for system on glass (SOG) and static random access memory (SRAM). Recently, the semiconductor industry is continuing its quest to create even more powerful CPU and memory chips. This requires increasing of individual device speed through the continual reduction of the minimum size of device features and increasing of device density on the chip. Moreover, the flat panel display industry also need to be brighter, with richer more vivid color, wider viewing angle, have faster video capability and be more durable at lower cost. Kornic Systems Co., Ltd. developed the $KORONA^{TM}$ LTP/GLTP series - an innovative production tool for fabricating flat panel displays and semiconductor devices - to meet these growing market demands and advance the volume production capabilities of flat panel displays and semiconductor industry. The $KORONA^{TM}\;LTP/GLTP$ series using DPSS laser and XeCl excimer laser is designed for the new generation of the wafer & FPD glass annealing processing equipment combining advanced low temperature poly-silicon (LTPS) crystallization technology and object-oriented software architecture with a semistandard graphical user interface (GUI). These leading edge systems show the superior annealing ability to the conventional other method. The $KORONA^{TM}\;LTP/GLTP$ series provides technical and economical benefits of advanced annealing solution to semiconductor and FPD production performance with an exceptional level of productivity. High throughput, low cost of ownership and optimized system efficiency brings the highest yield and lowest cost per wafer/glass on the annealing market.

  • PDF

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

Research Trends in Light Guide Plates for LED Backlight Units (LED 백라이트유닛 도광판의 연구동향)

  • Park, So Hee;Choi, Eun Seo;Ahn, Sun Young;Shin, Yong Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.314-326
    • /
    • 2017
  • The display, which is closely related to modern life, is being developed as a window on a network connecting individuals, devices, and even other individuals from simple display devices, as the IT industry develops. To achieve a thinner, brighter unit with less consumption for backlighting, the LED light source has applied, and the study of complex light-guiding plates to improve luminance, uniformity, and viewing angle has been initiated. In this paper, we summarize the research results for the scatterers' pattern formation of the light-guiding plate and the arrangement and composition of the light source, which have enabled remarkable development of the LED backlight unit over the last 10 years. In addition, a large-area flat-screen illumination system, applying the light-guiding-plate technology to a currently noteworthy LED light-fixture design, is outlined. Finally, we discuss the direction and way to develop the current technology more progressively.

Quantitative Analysis of Phosphors Decay Characteristic for Flicker-free Display System Design (플리커 저감 디스플레이 시스템 설계를 위한 인광체 잔광 특성의 정량적 해석)

  • Kwon, Yong-Dae;Choi, Duk-Kyu;Han, Chan-Ho;Lee, Gwang-Soon;Kim, Eun-Su;Lee, Sang-Hoon;Sohng, Kyu-Ik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.6
    • /
    • pp.9-16
    • /
    • 2000
  • The perception of flicker on the computer display devices depends upon the temporal waveform of the phosphor decay characteristic, the frame rate, and the display size. The lowest frequency at which flicker is not perceived is called the critical fusion frequency or critical frequency. Critical fusion frequency is evaluated by the display illuminance and the modulation (m) defined as the ratio of the amplitude of first harmonic frequency to the DC of the waveform. In this paper, we analyze the relationship bet ween the critical fusion frequency, relating to the decay characteristic of the phosphors and luminance on the monitor, and the frame frequency. Also under considering the viewing angle, we presented the frame frequency that is less sensitive to the full size of the display device.

  • PDF