• Title/Summary/Keyword: ViewRay

Search Result 382, Processing Time 0.029 seconds

12 Cases of Paranasal Sinusitis by Oriental Medicine (비연질환(부비동질환)鼻淵疾患(副鼻洞疾患)의 한방치험(韓方治驗) 12례(例))

  • Kim, Joong-Ho;Kim, Yoon-Bum;Chae, Byung-Yoon
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.113-121
    • /
    • 1994
  • We report 12 cases of paranasal sinusitis by the treatment of oriental medicines. Showing discharge from the nose. paranasal sinusitis is termed BIYEON(鼻淵) in the oriental medicine. Most of patient took GAMIBANGPUNGTONGSEONGSAN(加味防風通聖散). reported effect of antiphlogosis. antihistamine and antibiosis, for about five months. As a result the symptoms of paranasal sinusitis subsided. The radiographic diagnosis of sinusitis is generally based on opacification of the paranasal sinuses. Most of patients change the opacity of the maxillary sinuses on X-ray film in Water's view and Caldwell view by the treatment of Oriental medicine. We conclud that herbal medicines effect paranasal sinusitis.

  • PDF

The Geometric Modeling for 3D Information of X-ray Inspection (스테레오 X-선 검색장치를 이용한 3차원 정보 가시화에 관한 연구)

  • Hwang, Young-Gwan;Lee, Seung-Min;Park, Jong-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.145-149
    • /
    • 2014
  • In this study, using X-ray cargo container scanning device and to differentiate the concept of three-dimensional information extraction applied for X-ray scanning device as an ingredient in the rotation of the X-Ray Linear Pushbroom Stereo System by introducing the geometric How to model was introduced. Three-dimensional information obtained through the matching of a single voxel space filled with a random vector operations for each voxel in the three dimensional shape reconstruction algorithm using the definition, and in time, the time required for each step were analyzed. Using OpenCV in each step by applying parallelization techniques approximately 1.8 times improvement in the processing time of the check, but do not meet the target within one minute levels. The other hand, X-ray images by the primary process to convert the point View the results of real-time stereo through a three-dimensional could feel the comfort level.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Calibration Method for the Panel-type Multi-view Display

  • Kim, Jonghyun;Lee, Chang-Kun;Hong, Jong-Young;Jang, Changwon;Jeong, Youngmo;Yeom, Jiwoon;Lee, Byoungho
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 2015
  • We propose a novel calibration method which can be applied to all kinds of panel-type multi-view displays. We analyze how the angular, the axial, and the lateral misalignment affects the 3D image quality in a panel-type multi-view display. We demonstrate the ray optics simulation with a 3-view slanted parallax barrier system using pentile display for the quantitative calculation. Based on the analysis, we propose a new alignment pattern for all kinds of panel-type multi-view displays. The proposed pattern is sensitive to all of the angular, the axial, and the lateral misalignments. The high spatial frequency images and on and off alignment in the proposed pattern help observers to calibrate the system easily. We theoretically show the generality of the proposed alignment pattern and verify the pattern with image simulations and experiments.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

Evaluation of the Clinical Usefulness of an Assistive Device Fabricated by 3D Printing in an Oblique X-ray Examination of the Lumbar Vertebrae (허리뼈 사방향 X-선 검사에서 3D 프린팅으로 제작된 보조기구의 임상적 유용성 평가)

  • Kim, Hyeong-Gyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.505-512
    • /
    • 2022
  • In this study, a 3D printed assistive device was applied to X-ray examinations to diagnose human diseases. Based on the results of evaluating the device, statistical and regression analyses were conducted to evaluate its clinical utility and purchase intention, respectively. In the experiment, 90 radiologists performed X-ray examinations on patients who agreed with the use of the assistive device in oblique view X-rays of the lumbar spine, and then statistical analyses were undertaken with a traditional aid and factor analysis. The non-standardized coefficient values of the multiple regression analysis performed by setting the purchase intention of the 3D printed device as the dependent variable and the 3D printed device and traditional aid calculated by factor analysis as independent variables were 0.893 (p<0.001) and 0.269 (p<0.001), indicating statistically significant results. The results show that the 3D printed assistive device proposed in this study has higher clinical utility than traditional aids used in oblique view X-rays of the lumbar spine.

Adaptive Foveated Ray Tracing Based on Time-Constrained Rendering for Head-Mounted Display (헤드 마운티드 디스플레이를 위한 시간 제약 렌더링을 이용한 적응적 포비티드 광선 추적법)

  • Kim, Youngwook;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.113-123
    • /
    • 2022
  • Ray tracing-based rendering creates by far more realistic images than the traditional rasterization-based rendering. However, it is still burdensome when implemented for a Head-Mounted Display (HMD) system that demands a wide field of view and a high display refresh rate. Furthermore, for presenting high-quality images on the HMD screen, a sufficient number of ray sampling should be carried out per pixel to alleviate visually annoying spatial and temporal aliases. In this paper, we extend the recent selective foveated ray tracing technique by Kim et al. [1], and propose an improved real-time rendering technique that realizes the rendering effect of the classic Whitted-style ray tracing on the HMD system. In particular, by combining the ray tracing hardware-based acceleration technique and time-constrained rendering scheme, we show that fast HMD ray tracing is possible that is well suited to human visual systems.

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Rapid Stitching Method of Digital X-ray Images Using Template-based Registration (템플릿 기반 정합 기법을 이용한 디지털 X-ray 영상의 고속 스티칭 기법)

  • Cho, Hyunji;Kye, Heewon;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.701-709
    • /
    • 2015
  • Image stitching method is a technique for obtaining an high-resolution image by combining two or more images. In X-ray image for clinical diagnosis, the size of the imaging region taken by one shot is limited due to the field-of-view of the equipment. Therefore, in order to obtain a high-resolution image including large regions such as a whole body, the synthesis of multiple X-ray images is required. In this paper, we propose a rapid stitching method of digital X-ray images using template-based registration. The proposed algorithm use principal component analysis(PCA) and k-nearest neighborhood(k-NN) to determine the location of input images before performing a template-based matching. After detecting the overlapping position using template-based matching, we synthesize input images by alpha blending. To improve the computational efficiency, reduced images are used for PCA and k-NN analysis. Experimental results showed that our method was more accurate comparing with the previous method with the improvement of the registration speed. Our stitching method could be usefully applied into the stitching of 2D or 3D multiple images.

Stochastic nature of magnetic processes studied by full-field soft X-ray microscopy

  • Im, Mi-Young
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1174-1181
    • /
    • 2018
  • In nanomagnetism, one of the crucial scientific questions is whether magnetic behaviors are deterministic or stochastic on a nanoscale. Apart from the exciting physical issue, this question is also of paramount highest relevance for using magnetic materials in a wealth of technological applications such as magnetic storage and sensor devices. In the past, the research on the stochasticity of a magnetic process has been mainly done by macroscopic measurements, which only offer ensemble-averaged information. To give more accurate answer for the question and to fully understand related underlying physics, the direct observation of statistical behaviors in magnetic structures and magnetic phenomena utilizing advanced characterization techniques is highly required. One of the ideal tools for such study is a full-field soft X-ray microscope since it enables imaging of magnetic structures on the large field of view within a few seconds. Here we review the stochastic behaviors of various magnetic processes including magnetization reversal process in thin films, magnetic domain wall motions in nanowires, and magnetic vortex formations in nanodisks studied by full-field soft X-ray microscopy. The origin triggering the stochastic nature witnessed in each magnetic process and the way to control the intrinsic nature are also discussed.