• 제목/요약/키워드: ViewRay

검색결과 380건 처리시간 0.021초

Pelvic AP X-ray 촬영 자세에 따른 골반변위 변화의 비교 연구 (A Comparative Study on the Changes of Pelvic Alignment between AP View of the Pelvis in Standing and Supine Position)

  • 이경무;박동수;김순중;정수현
    • 한방재활의학과학회지
    • /
    • 제18권4호
    • /
    • pp.161-169
    • /
    • 2008
  • Objectives : This study was carried out to investigate the relationship of pelvic alignment between AP view of the pelvis in standing and supine position. Methods : Sixteen healthy peoples who get $51.59{\pm}4.14$ as average in SF-36 were evaluated by X-ray findings. After measuring innomiate measurement, off centering measurement, sacral ala measurement, illium shadow measurement, the area of obturator foramen, those were analyzed statistically. Results : It was not all to be corresponded to distort pelvic alignment of AP view of the pelvis in standing and in supine. Sometimes it was the opposite result. Conclusions : These results suggest that the diagnosis of pelvic alignment to go through on each position is brought about disagreement with each other.

원판형 연골에서 단순 방사선 검사의 의의 (X-ray Significance in Discoid Meniscus)

  • 안진환;하권익;김형국;김호
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.102-107
    • /
    • 1997
  • Discoid meniscus has been well known to a frequent anomaly of meniscus and much reported in diagnosis and treatment. But, associated X-ray findings have not been known well. We reported its significance of X-ray findings in discoid meniscus. From May 1995 to May 1997, 31 cases of discoid meniscus were compared with 51 cases of nondiseoid meniscus both confirmed by arthroscopy, with simple X-my findings. Both groups were evaluated by X-ray findings in view of lateral joint space widening, peripheral spur of lateral joint space, sclerotic change of lateral tibial plateau, concave lateral tibial plateau, flattening of lateral femoral condyle, hypoplasia of lateral femoral condyle and high riding fibula. The results of analysis were as follows: 1. Widening of lateral joint space, sclerotic change of lateral tibial plateau and cupping of lateral tibial plateau were statistically significant in discoid meniscus. 2. X-ray findings in discoid meniscus were not associated with patient's injury history and symptom duration. 3. Other X-ray findings were not related in discoid meniscus significantly. X-ray findings with patient's history and physical examination arc helpful in the diagnosis of discoid meniscus.

  • PDF

X-ray를 통한 예풍(藝風)과 하관(何關)에서의 안전한 자침 깊이에 대한 고찰 (Determination of Safe Needling Depth via X-ray at $TE_{17}$(Yifeng) and $ST_7$(Xiaguan))

  • 변혁;강민주;정찬영;박인식;조현석;김경호;이승덕;김갑성
    • Journal of Acupuncture Research
    • /
    • 제24권6호
    • /
    • pp.69-73
    • /
    • 2007
  • 목적 : X-ray를 통해 안면마비에 다용되는 예풍과 안면통에 다용되는 하관에서의 안전한 자침 깊이에 대하여 고찰하여 보고자 하였다. 방법 : 건강한 지원자들에게 원치 않을 경우 언제든지 시험을 중지할 권리가 있다는 것을 공지한 후, 시험에 동의한 남녀 각각 2명의 피험자들을 대상으로 대학병원 침구과 전문의가 예풍과 하관을 직자(直刺)($40mm{\times}0.35mm$ 일회용 침)하였다. 피험자의 이상 반응 유무를 살피며 안면신경 혹은 삼차신경이 지나가는 경로로 알려진 깊이까지 진침(進鎬)하였다. 유침(留鍼) 상태에서 Skull X-ray의 AP view와 Lateral view를 촬영하였다. 결과 : 피험자들은 침병이 피부에 도달 하는 동안(40mm 직자) 자침 혈위에서 중창감(重脹感)을 자각하였으며, 추후 어떠한 이상 반응도 보이지 않았다. 결론 : 안면마비와 안면통의 효율적인 치료를 위하여 안면신경과 삼차신경에 근접할 수 있는 혈위인 예풍과 하관에서의 40mm 직자는 신경염이나 뇌 손상과 같은 이상 반응을 유발하지 않았다.

  • PDF

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

내측광근 강화운동을 이용한 슬개-대퇴 동통 증후군 치험 2례 (A Case Report of Two Patients with Patello-Femoral Pain Syndrome Using Exercises for Vastus Medialis)

  • 김종수;김진수;김세준;정승현;김효섭;윤문식;조태영
    • 척추신경추나의학회지
    • /
    • 제8권1호
    • /
    • pp.75-85
    • /
    • 2013
  • 슬개-대퇴 통증 증후군 환자 2례에 내측광근 강화 운동을 이용하여 치료한 결과, Knee X-ray(Skyline view) 상의 일치각 및 NRS, WOMAC Index의 호전을 확인하였다. 이에 저자는 본 증례를 보고하는 바이다.

  • PDF

Quantifications of Intensity-Modulated Radiation Therapy Plan Complexities in Magnetic Resonance Image Guided Radiotherapy Systems

  • Chun, Minsoo;Kwon, Ohyun;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제46권2호
    • /
    • pp.48-57
    • /
    • 2021
  • Background: In this study, the complexities of step-and-shoot intensity-modulated radiation therapy (IMRT) plans in magnetic resonance-guided radiation therapy systems were evaluated. Materials and Methods: Overall, 194 verification plans from the abdomen, prostate, and breast sites were collected using a 60Co-based ViewRay radiotherapy system (ViewRay Inc., Cleveland, OH, USA). Various plan complexity metrics (PCMs) were calculated for each verification plan, including the modulation complexity score (MCS), plan-averaged beam area (PA), plan-averaged beam irregularity, plan-averaged edge (PE), plan-averaged beam modulation, number of segments, average area among all segments (AA/Seg), and total beam-on time (TBT). The plan deliverability was quantified in terms of gamma passing rates (GPRs) with a 1 mm/2% criterion, and the Pearson correlation coefficients between GPRs and various PCMs were analyzed. Results and Discussion: For the abdomen, prostate, and breast groups, the average GPRs with the 1 mm/2% criterion were 77.8 ± 6.0%, 79.8 ± 4.9%, and 84.7 ± 7.3%; PCMs were 0.263, 0.271, and 0.386; PAs were 15.001, 18.779, and 35.683; PEs were 1.575, 1.444, and 1.028; AA/Segs were 15.37, 19.89, and 36.64; and TBTs were 18.86, 19.33, and 5.91 minutes, respectively. The various PCMs, i.e., MCS, PA, PE, AA/Seg, and TBT, showed statistically significant Pearson correlation coefficients of 0.416, 0.627, -0.541, 0.635, and -0.397, respectively, with GPRs. Conclusion: The area-related metrics exhibited strong correlations with GPRs. Moreover, the AA/Seg metric can be used to estimate the IMRT plan accuracy without beam delivery in the 60Co-based ViewRay radiotherapy system.

Impact of 0.35 T Magnetic Field on Dose Calculation for Non-small Cell Lung Cancer Stereotactic Radiotherapy Plans

  • Jaeman Son;Sung Young Lee;Chang Heon Choi;Jong Min Park;Jung-in Kim
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.117-123
    • /
    • 2023
  • Background: We investigated the impact of 0.35 T magnetic field on dose calculation for non-small cell lung cancer (NSCLC) stereotactic ablative radiotherapy (SABR) in the ViewRay system (ViewRay Inc.), which features a simultaneous use of magnetic resonance imaging (MRI) to guide radiotherapy for an improved targeting of tumors. Materials and Methods: Here, we present a comprehensive analysis of the effects induced by the 0.35 T magnetic field on various characteristics of SABR plans including the plan qualities and dose calculation for the planning target volume, organs at risk, and outer/inner shells. Therefore, two SABR plans were set up, one with a 0.35 T magnetic field applied during radiotherapy and another in the absence of the field. The dosimetric parameters were calculated in both cases, and the plan quality indices were evaluated using a Monte Carlo algorithm based on a treatment planning system. Results and Discussion: Our findings showed no significant impact on dose calculation under the 0.35 T magnetic field for all analyzed parameters. Nonetheless, a significant enhancement in the dose was calculated on the skin surrounding the tumor when the 0.35 T magnetic field was applied during the radiotherapy. This was attributed to the electron return effect, which results from the deviation of the electrons ejected from tissues upon radiation due to Lorentz forces. These returned electrons re-enter the tissues, causing a local dose increase in the calculated dose. Conclusion: The present study highlights the impact of the 0.35 T magnetic field used for MRI in the ViewRay system for NSCLC SABR treatment, especially on the skin surrounding the tumors.

Rotating-Gantry-Based X-Ray Micro-Tomography System with the Sliding Mechanism Capable of Zoom-In Imaging

  • Cho, Min-Hyoung;Lee, Dong-Hun;Han, Byung-Hee;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.107-113
    • /
    • 2008
  • We introduce a rotating-gantry-based x-ray micro-tomography system to be used for small animal imaging studies. It has the zoom-in imaging capability for high resolution imaging of a local region inside the animal subject without any contrast anomalies arising from truncation of the projection data. With the sliding mechanism mounted on the rotating gantry holding the x-ray source and the x-ray detector, we can control the magnification ratio of the x-ray projection data. By combining the projection data from the large field of view (FOV) scan of the whole animal subject and the projection data from the small FOV scan of the region of interest, we can obtain artifact-free zoomed-in images of the region of interest. For the acquisition of x-ray projection data, we use a $1248{\times}1248$ flat-panel x-ray detector with the pixel pitch of 100 mm. It has been experimentally found that the developed system has the spatial resolution of up to 121p/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging. We present some in vivo rat femur images to demonstrate utility of the developed system for small animal imaging.

Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법 (Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures)

  • 송주현;이주엽;양성철;이한용;김종익
    • Clinics in Shoulder and Elbow
    • /
    • 제10권2호
    • /
    • pp.199-203
    • /
    • 2007
  • 목적: 구상돌기는 주관절의 안정성 및 기능에 매우 중요하기 때문에, 구상돌기 골절 시 정확한 골편의 평가 및 고정이 매우 중요하다. 구상돌기 골절에 대한 방사선학적 평가는 주로 주관절 측면 촬영에서 하게 되는데, 요골두와 겹치기 때문에 정확한 관찰이 어려울 수 있다. 이에 저자들은 구상돌기 골절의 평가를 위한 새로운 방사선 촬영 방법, coronoid view를 고안하여 소개하고자 한다. 대상 및 방법: coronoid view는 구상돌기 골절 중 특히 사선의 골절선을 갖는 전내측 골편을 평가하기 위하여 고안되었다. 환자를 촬영대에 대하여 직각이 되게 옆으로 앉힌 후, 환측 견관절을 45도 외전하고, 주관절을 90도 굴곡한 상태에서 촬영대 위에 팔을 놓는다. 필름은 주관절 밑에 놓고, 주관절의 직상방에서 주관절을 중심으로 방사선을 조사한다. 이 방법으로 구상돌기 골절선이 방사선과 평행이 될 수 있으며, 요골두가 겹치는 것을 피할 수 있다. 결론: coronoid view는 구상돌기 골절선이 방사선과 평행이 될 수 있으며, 요골두 음영을 피할 수 있기 때문에 구상돌기 골절의 정확한 평가에 도움이 될 것으로 판단된다. 특히 금속 나사 등의 내고정물 때문에 컴퓨터 단층촬영이 불가능한 관혈적 정복술 후 환자의 경과 관찰에 특히 유용할 것으로 판단된다.

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.