• Title/Summary/Keyword: ViewRay

Search Result 384, Processing Time 0.029 seconds

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

A Demodulation Method for DS/CDMA Systems (DS/CDMA 시스템을 위한 새로운 복조 방식)

  • Jung, Bum-Jin;Jin, Ming-Lu;Kwak, Kyung-Sup
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.212-224
    • /
    • 1998
  • There are two major factors of degrading the performance in the forward link of DS/CDMA systems. One is the multiple access interference (MAI) caused by using the same frequency bands simultaneously and the other is the multipath lading due to multipath propagation. PN codes which have minimum cross correlation properties among spread spectrum codes are necessary to reduce the MAI. In the conventional IS-95A system, the PN sequence has the period of $2^{15}$ and is of the length of 64 chips for spreading each data. In this case, since the length of PN code per bit is very short compared to the period of the PN code, the performance of the conventional system is not satisfied in view of suppressing the multipath interference. However, the correlation property of the PN codes at the demodulation can be improved by increasing the interval of Integration at the demodulation. This paper proposes a demodulation method to reduce the cross correlation among PN codes. The performance of the proposed demodulation method is investigated through computer simulations. We used multipath Ray lading channel and AWGN channel in the simulation. Our simulation results show the improved performance of $0.25{\sim}0.5dB$ SNR in a given BER compared to the conventional demodulation scheme.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the SABR Plans for Liver Cancer

  • Son, Jaeman;Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Chie, Eui Kyu;Yoon, Jeongmin;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.47-52
    • /
    • 2018
  • To investigate the effect of low magnetic field on dose distribution in SABR plans for liver cancer, we calculated and evaluated the dose distribution to each organ with and without magnetic fields. Ten patients received a 50 Gy dose in five fractions using the $ViewRay^{(R)}$ treatment planning system. For planning target volume (PTV), the results were analyzed in the point minimum ($D_{min}$), maximum ($D_{max}$), mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$), and 100% ($V_{100%}$) of the prescription dose, respectively. For organs at risk (OARs), the duodenum and stomach were analyzed with $D_{0.5cc}$ and $D_{2cc}$, and the remained liver except for PTV was analyzed with $D_{mean}$, $D_{max}$, and $D_{min}$. Both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$, and $D_{mean}$, respectively. For PTV, the maximum change in volume due to the presence or absence of the low magnetic field showed a percentage difference of up to $0.67{\pm}0.60%$. In OAR analysis, there is no significant difference for the magnetic field. In both shell structure analyses, although there are no major changes in dose distribution, the largest value of deviation for $D_{max}$ in the outer shell is $2.12{\pm}2.67Gy$. The effect of low magnetic field on dose distribution by a Co-60 beam was not significantly observed within the body, but the dose deposition was only appreciable outside the body.

The Complications of the Graf Stabilization for Lumbar Disc Herniation with Posterior Instability (후방불안정성을 동반한 요추 추간판 탈출증에서 Graf 고정술후 발생한 합병증 분석)

  • Park, Joo-Tae;Shin, Young-Shik;Yang, Jeong-Ho;Min, Kang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.164-172
    • /
    • 1998
  • The Graf stabilization has been introduced in treating lumbar spinal disorder associated with posterior instability. This study reviewed some problems of the Graf instrumentation as a soft stabilizer. The purpose of this study is to analyse the problems of the soft stabilization in spinal instability. We reviewed 145 cases which were operative treatment using the Graf instrument for lumbar spinal disorder associated with posterior instability at our department from May, 1991 to Dec, 1995. The mean follow up periods was 29 months ranging from 24 months to 6 years 8 months. Of the 145 cases, 22 cases were showed the problem. The diagnostic method were simple x-ray, flexion-extension lateral stress view and CT scan. Results were as follows: Adjacent segmental instability was 10 cases(6.9%), disc space narrowing was 8 cases(5.5%), screw loosening was 3 cases(2.1%) and breakage of the Graf band was 1 case(0.6%). The problems of the soft stabilization were adjacent segmental instability, disc space narrowing, screw loosening, and breakage of the Graf band. But the rate of adjacent segmental instability and disc space narrowing was lower than other lumbar spinal instrumentation.

  • PDF

Design of Automatic Classification System of Black Plastics Based on Support Vector Machine Using Raman Spectroscopy (라만분광법을 이용한 SVM 기반 흑색 플라스틱 자동 분류 시스템의 설계)

  • Bae, Jong-Soo;Oh, Sung-Kwun;Kim, Hyun-Ki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.416-422
    • /
    • 2016
  • Lots of plastics are widely used in a variety of industrial field. And the amount of plastic waste is massively produced. In the study of waste recycling, it is emerged as an important issue to prevent the waste of potentially useful resource materials as well as to reduce ecological damage. So, the recycling of plastic waste has been currently paid attention to from the view point of reuse. Existing automatic sorting system consist of near infrared ray (NIR) sensors to classify the types of plastics. But the classification of black plastics still remains a challenge. Black plastics which contains carbon black are not almost classified by NIR because of the characteristic of the light absorption of black plastics. This study is focused on handling how to identify black plastics instead of NIR. Raman spectroscopy is used to get qualitative as well as quantitative analysis of black plastics. In order to improve the performance of identification, Support Vector Machine(SVM) classifier and Principal Component Analysis(PCA) are exploited to more preferably classify some kinds of the black plastics, and to analyze the characteristic of each data.

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Surface Modification of Polymethylmethacrylate(PMMA) by Ion-assisted reaction (이온 보조 반응법(Ion-assisted-reaction)을 이용한 Polymethylmethacrylate (PMMA)의 표면개질)

  • Jung, Sun;Cho, Jun-Sik;Choi, Sung-Chang;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.446-451
    • /
    • 1999
  • Surface of Polymethylmethacrylate (PMMA) was modified by ion assisted reaction in which ion beam of Ar or$ O_2$is irradiated on polymer in reaction gas environment. Ion beam energy was changed from 600 to 1000eV, and ion doses were varied from $5\times10^{14} ions/cm^2 to 1\times10^{17} ions/cm^2$. Contact angle and surface energy of modified PMMA were measured by contact angle micrometer using distilled water and formamide. In the case of $Ar^+$ ion irradiation only, the contact angle reduced from $68^{\circ} to $35^{\circ}$ and the surface energy was changed from 46 dyne/cm to 60 dyne/cm. The contact angle significantly decreased to $14^{\circ}$and the surface energy increased to 72 dyne/cm when the surface of PMMA was modified by oxygen ion irradiation in oxygen gas environment. Improvement of wettability results from the formation of new hydrophilic group which is identified as C-O chain by XPS analysis. Recovery of wettability in dry air and maintenance of it in water condition were explained in view of the formation of hydrophilic group.

  • PDF

Optical Multi-Normal Vector Based Iridescence BRDF Compression Method (광학적 다중 법선 벡터 기반 훈색(暈色)현상 BRDF 압축 기법)

  • Ryu, Sae-Woon;Lee, Sang-Hwa;Park, Jong-Il
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.37 no.3
    • /
    • pp.184-193
    • /
    • 2010
  • This paper proposes a biological iridescence BRDF(Bidirectional Reflectance Distribution Function) compression and rendering method. In the graphics technology, iridescence sometimes is named structure colors. The main features of these symptoms are shown transform of color and brightness by varying viewpoint. Graphics technology to render this is the BRDF technology. The BRDF methods enable realistic representation of varying view direction, but it requires a lot of computing power because of large data. In this paper, we obtain reflection map from iridescence BRDF, analyze color of reflection map and propose representation method by several colorfully concentric circle. The one concentric circle represents beam width of reflection ray by one normal vector. In this paper, we synthesize rough concentric by using several virtually optical normal vectors. And we obtain spectrum information from concentric circles passing through the center point. The proposed method enables IBR(image based rendering) technique which results is realistic illuminance and spectrum distribution by one texture from reduced BRDF data within spectrum.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.