• Title/Summary/Keyword: ViewRay

Search Result 384, Processing Time 0.023 seconds

Trend on Recycling Technologies for Display Wastes analysed by the Patents and Literature Review (특허(特許)와 논문(論文)으로 본 폐(廢) 디스플레이 재활용(再活用) 기술(技術) 동향(動向))

  • Lee, Sung-Kyu;Lee, Chan-Gi;Hong, Hyun-Seon;Cho, Young-Ju;Cho, Bong-Gyoo
    • Resources Recycling
    • /
    • v.21 no.3
    • /
    • pp.65-73
    • /
    • 2012
  • There are several kinds of displays such as liquid crystal display (LCD), cathode ray tube (CRT), plasma display panel(PDP), light emitting diode (LED), organic light emitting diode (OLED), etc. Nowadays, recycling technologies of waste displays have been widely studied from economy and efficiency points of view. In this paper, patents and literature on the recycling technologies of the waste displays have been comprehensively analyzed. The search was limited to the open patents of USA (US), European Union (EU), Japan (JP), and Korea (KR) and SCI journals published from 1980 to 2011. Patents and journals were systematically compiled and collected using key-words search and filtered by pre-set filtering criteria. The trends of the patents and journals were thus analyzed according to the years, countries, companies, and technologies.

Korean Clinic Based Outcome Measure Studies (한방 병-의원에서 하는 임상지표 연구)

  • Park, Jong-Bae
    • Journal of Pharmacopuncture
    • /
    • v.6 no.1
    • /
    • pp.35-36
    • /
    • 2003
  • Background: Evidence based medicine has become main tools for medical practice. However, conducting a highly ranked in the evidence hierarchy pyramid is not easy or feasible at all times and places. There remains a room for descriptive clinical outcome measure studies with admitting the limit of the intepretation. Aims: Presents three Korean clinic based outcome measure studies with a view to encouraging Korean clinicians to conduct similar studies. Methods: Three studies are presented briefly here in치uding 1) Quality of Life of liver cancer patients after 8 Constitutional acupuncture; 2) Developing a Korean version of Measuring yourself Medical Outcome profile (MYMOP); and 3) Survey on 5 Shu points: a pilot In the first study, we have included 4 primary or secondary liver cancer patients collecting their diagnostic X-ray film and clinical data f개m their hospital, and asked them to fill in the European Organization Research and Treatment of Cancer, Quality of Life Questionnaire before the commencement of the treatment. The acupuncture treatment is set up format but not disclosed yet. The translation and developing a Korean version of outcome measures that is Korean clinician friendly has been sought for MYMOP is one of the most appropriate one. The permission was granted, the translation into Korean was done, then back translated into English only based on the Korean translation by the researcher who is bilingual in both languages. The back translation was compared by the original developer of MYMOP and confirmed usable. In order to test the existence of acupoints and meridians through popular forms of Korean acupuncture regimes, we aim at collecting opinions from 101 Korean clinicians that have used those forms. The questions asked include most effective symptoms, 5 Shu points, points those are least likely to use due to either adverse events or the lack of effectiveness, theoretical reasons for the above proposals, proposing outcome measures, and the time from insertion to be effective. The questionnaire is posted on the virtual notice board of the homepage of the communication KOMA (The official tool of Association of Korean Oriental Medicine).

Finding of Relation Between 4th Lumbar Rotational Malposition and Scoliosis (요추 4번의 회전변위와 척추측만증과의 상관성에 관한 연구)

  • Kim, Gyu-Sub;Kim, Jae-Young;Min, Young-Kwang;Seo, Young-Tae;Sung, Ik-Jae;Lee, Seung-Woo;Jee, Jae-Dong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • Objectives : The purpose of this study is to find out the relation between 4th lumbar rotational malposition and scoliosis. Methods : We investigated 22 cases of patients who were diagnosed as scoliosis. We used AP & Lateral view X-ray for patients. And we analysed the relation between 4th lumbar rotational malposition and scoliosis. Results : P-value was 0.436 between 4th lumbar rotational amount and lordotic angle, and was 0.758 between 4th lumbar rotational amount and wedge angle(p>0.05). And p-value was 0.022 between 4th lumbar rotational amount and scoliotic apex rotational amount(p<0.05), but was 0.286 between 4th lumbar rotational amount and Cobb's angle(p>0.05). Conclusions : The results suggest that 4th lumbar rotational malposition was statistically correlation with scoliotic apex rotational malposition, was not Cobb's angle, 4th lumbar lordotic & wedge angle.

  • PDF

The Effect of Dwyer's Osteotomy and the 1st Metatarsal Osteotomy for Cavovarus Correction on Radiographic Parameters (요내반족 교정에 있어 드와이어씨 절골술 및 제 1중족골 절골술이 방사선학적 지표에 미치는 영향)

  • Choi, Jun Young;Cha, Seong Mu;Yeom, Ji Woong;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.1
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose: Several techniques have been introduced for correction of pes cavo-varus deformity. We retrospectively reviewed and compared the data of patients who underwent 1st metatarsal osteotomy alone, Dwyer's osteotomy alone, and 1st metatarsal osteotomy combined with Dwyer's osteotomy to determine the effect on radiographic parameters. Materials and Methods: Data on 28 cases in 27 consecutive patients recruited from 2006 to 2014 who underwent 1st metatarsal osteotomy alone (group F), Dwyer's osteotomy alone (group H), or 1st metatarsal osteotomy followed by Dwyer's osteotomy (group HF) with a minimum 1-year follow-up were reviewed retrospectively. Results: Calcaneal pitch angle on the standing foot lateral radiographs was significantly decreased after the operation in groups H and HF whereas Meary angle was decreased in groups F and HF. Hindfoot alignment angle and ratio on the hindfoot alignment view were improved in groups H and HF. Maximal medial cuneiform height reduction was observed in group HF. 1st ray was significantly shortened in groups F and HF. Conclusion: Combined forefoot and hindfoot operation took the largest correction power of all radiologic parameters.

Gemological Identification of Black Diamonds Roughs from Zimbabwe (짐바브웨산 블랙다이아몬드 원석의 보석학적 감별연구)

  • Song, Oh-Sung;Kim, Jun-Hwan;Kim, Ki-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3054-3059
    • /
    • 2009
  • Natural black diamonds of single crystal, polycrystalline, and agglomerated roughs become important for their industrial and gem stone application. We performed the conventional gemological tests of thermal diffusion, apparent density, scratch test, and magnification test as well as the advanced tests of Raman spectroscopy, X-ray diffraction test and Lang topography. We conclude that scratch test with SiC paper was the most efficient method in view point of speed and cost. Raman spectroscopy and XRD were useful for identification of diamond while Lang topography offered a good visualization method of the grain structure of polycrystalline black diamond roughs.

Dependence of Poling Field on Pyroelectric Property of $Pb_{0.9}La_{0.1}TiO_3$ Ceramics

  • D. J. You;B. S. Kang;Park, S. K.
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.291-295
    • /
    • 2000
  • The pyroelectric property of $Pb_{0.9}La$_{0.1}TiO_3$ceramics in a range of 1.3-4.1$\mu\textrm{m}$, fabricated by conventional solid sintering, was investigated as a function of poling field. The pyroelectric of the 4.1$\mu\textrm{m}$ of $Pb_{0.9}La$_{0.1}TiO_3$ceramics is higher than that of the 1.3$\mu\textrm{m}$ and 1.7$\mu\textrm{m}$ of $Pb_{0.9}La$_{0.1}TiO_3$ceramics at a low poling field and the pyroelectric coefficient is 25nC/$\textrm{cm}^2$K at a 4kV/mm poling field in every grain size. In order to explain this phenomenon, the intrinsic and extrinsic effects in view of the definition of the pyroelectric coefficient are introduced. The intrinsic and extrinsic effects on the pyroelectric property were investigated by measuring the tetragonal ratio and the $I_{002}$ with temperature with high temperature X-ray diffractometer. The change of spontaneous polarization and the $90^{\circ}$domain wall motion with temperature in the 1.3$\mu\textrm{m}$ and 4.2$\mu\textrm{m}$ of $Pb_{0.9}La$_{0.1}TiO_3$ceramics have no effects on the pyroelectric coefficient. In our study, it can be seen that the pyroelectric coefficient is related to the quantity of $180^{\circ}$domain switching after poling treatment.

  • PDF

fabrication of DMMP Thick Film Gas Sensor Based on SnO2 (산화주석을 기반으로 한 DMMP 후막가스센서 제작)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1217-1223
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is dimethyl methyl phosphonate(C$_3$ $H_{9}$ $O_3$P, DMMP) that is simulant gas of nerve gas. Sensing materials were Sn $O_2$ added a-Al$_2$ $O_3$ with 0∼20wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor device was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Total size of device was 7${\times}$10${\times}$0.6㎣. Crystallite size & phase identification and morphology of fabricated Sn $O_2$ powders were analyzed by X-ray diffraction and by a scanning electron microscope, respectively. Fabricated sensor was measured as flow type and resistance change of sensing material was monitored as real time using LabVIEW program. The best sensitivity was 75% at adding 4wt.% $\alpha$-Al$_2$ $O_3$, operating temperature 30$0^{\circ}C$ to DMMP 0.5ppm. Response and recovery time were about 1 and 3min., respectively. Repetition measurement was very good with $\pm$3% in full scale.TEX>$\pm$3% in full scale.

Effect of Lead Concentration on Surface Oxide Formed on Alloy 600 in High Temperature and High Pressure Alkaline Solutions (고온, 고압 알칼리 수용액에서의 Alloy 600 산화막 특성에 미치는 납 농도 영향)

  • Kim, Dong-Jin;Kim, Hyun Wook;Moon, Byung Hak;Kim, Hong Pyo;Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.96-102
    • /
    • 2012
  • Outer diameter stress corrosion cracking (ODSCC) has occurred for Alloy 600 (Ni 75 wt%, Cr 15 wt%, Fe 10 wt%) as a heat exchanger tube of the steam generator (SG) in nuclear power plants (NPP) during long term operation. Among many causes for SCC, lead (Pb) is known to be one of the most deleterious species in the secondary system. In the present work, the oxide formed on Alloy 600 was characterized as a function of the PbO content in 0.1 M NaOH at $315^{\circ}C$ by using an electrochemical impedance spectroscopy (EIS), a transmission electron microscopy (TEM), equipped with an energy dispersive x-ray spectroscopy (EDS). The oxide property was analyzed in view of SCC susceptibility.

Forward-Looking Ultrasound Imaging Transducer : I. Analysis and Design (전향 초음파 영상 트랜스듀서 : I. 해석 및 설계)

  • Lee, Chan-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.73-86
    • /
    • 1995
  • The transducer section of the forward-looking ultrasound imaging catheter (FLUIC) consists of a circular piezoelectric element as a vibrator and a conical acoustic mirror as a perfect reflector. A small diameter piezoelectric transducer element is mounted on the side of a catheter's rotating shaft. The unique design of FLUIC provides the capability to form a two-dimensional image of a cross-section of vessel in front of the catheter, which is lacking in the present generation of intravascular ultrasound (IVUS) transducers, as well as a conventional side view image. The mirror configuration for the transducer section of the FLUIC is designed using an approximated ray tracing techniques. The diffraction transfer function approach [1] developed for the field prediction from primary sources is generalized and extended to predict the secondary diffraction characterstics from an acoustic mirror. The extended model is verified by simulation and experiment through a simple plane reflector and employed to analyzed the field characteristics of a FLUIC.

  • PDF

Interventional Pain Management in Rheumatological Diseases - A Three Years Physiatric Experience in a Tertiary Medical College Hospital in Bangladesh

  • Siddiq, Md. Abu Bakar;Hasan, Suzon Al;Das, Gautam;Khan, Amin Uddin A.
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.205-215
    • /
    • 2011
  • Background: Interventional pain management (IPM) is a branch of medical science that deals with management of painful medical conditions using specially equipped X-ray machines and anatomical landmarks. Interventional physiatry is a branch of physical medicine and rehabilitation that treats painful conditions through intervention in peripheral joints, the spine, and soft tissues. Methods: A cross-sectional study was conducted using three years of hospital records (2006 to 2008) from the Physical Medicine and Rehabilitation Department at Chittagong Medical College Hospital in Bangladesh, with a view toward highlighting current interventional pain practice in a tertiary medical college hospital. Result: The maximum amount of intervention was done in degenerative peripheral joint disorders (600, 46.0%), followed by inflammatory joint diseases (300, 23.0%), soft tissue rheumatism (300, 23.0%), and radicular or referred lower back conditions (100, 8.0%). Of the peripheral joints, the knee was the most common site of intervention. Motor stimulation-guided intralesional injection of methylprednisolone into the piriformis muscle was given in 10 cases of piriformis syndrome refractory to both oral medications and therapeutic exercises. Soft tissue rheumatism of unknown etiology was most common in the form of adhesive capsulitis (90, 64.3%), and is discussed separately. Epidural steroid injection was practiced for various causes of lumbar radiculopathy, with the exception of infective discitis. Conclusion: All procedures were performed using anatomical landmarks, as there were no facilities for the C-arm/diagnostic ultrasound required for accurate and safe intervention. A dedicated IPM setup should be a requirement in all PMR departments, to provide better pain management and to reduce the burden on other specialties.